Search Results: 18-CH94D1-1C-EN

Showing 1,051 - 1,060 of 7,187 results

Display results per page.
  • Media type icon

    ODR-PSD010B-EN_09202025

    Document Title:Split System Cooling
    Publication Type:Product and Submittal Data
    Publication Date:2025-09-20
    ODR-PSD010B-EN_09202025 September 2025 ODR-PSD010B-EN Split System Cooling5TTX5018A1000A5TTX5024A1000A5TTX5030A1000A/B5TTX5036A1000A/B5TTX5042A1000A/B5TTX5048A1000A/B5TTX5060A1000A/B Note: Graphics in this document are for representation only.Actual model may differ in appearance. Product and
  • Media type icon

    SO-SVN027C-EN_07142024

    OF GRAVITY Y X Z X Y Z SO-SVN027C-EN 17 Pre-Installation Figure 4. Unit lifting points and center of gravity (remote mount) 42.33 0 15.4 50 7.60 0 6.82 X Y ZORIGINAL 0 0 0CENTER OFGRAVITY 15.45 42.33 7.60 CENTEROF GRAVITY CENTER OF GRAVITY CENTER OF GRAVITY Y X ZX YZ 18 SO-SVN027C-EN Pre
  • Media type icon

    CTV-SLB059-EN_05152020

    Warranties12/18 Standard Parts Warranty All CenTraVac chillers come with this warranty, which covers replacement parts in the event of a failure due to manufacturing defect. The coverage begins at startup and ends the earlier of 12 months from initial startup or 18 months after shipment from the Trane
  • Media type icon

    5071-1335D_08132013

    Document Title:Schematic - CenTraVac - CH531 Wiring Diagram with Danfoss Adaptive Frequency Drive
    Publication Type:Wiring Diagram or Manual
    Publication Date:2013-08-13
    DESCARGA DE QUE TODOS LOS CAPACITORES DEL MOTOR DAMAGE TO THE EQUIPMENT.FAILURE TO DO SO MAY CAUSE OTHER TYPES OF CONDUCTORS.UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT PEUT ENDOMMAGER L'ÉQUIPEMENT. EN CUIVRE! TYPES DE CONDUCTEURS. LES BORNES DE L'UNITÉ NE SONT L'UTILISATION DE TOUT AUTRE CONDUCTEUR PAS
  • Media type icon

    MXW-SVN15A-EN_06012009

    Document Title:Trane Installation Manual - Split System (R410A) 16 SEER, Inverter Units 9,000 to 24,000 BTU/Hr - Models: Heat Pump 4MXW6 4TXW6 4MXW6 4TXW6
    Publication Type:Installation
    Publication Date:2009-06-01
    Superseded By:MXW-SVN15A-EN
    . All field wiring MUST be performed by qualified personnel. Failure to follow these requirements could result in death or serious injury. Heat Pump High Efficiency 50 Hz models Wiring Diagrams Figure 2. 4TXK6509ABAA (Outdoor) MXW-SVN15A-EN 17 Wiring Diagrams Figure 3. 4MXW6509ABAA (Indoor) 18 MXW
  • Media type icon

    AH-PRC014A-EN_08222022

    -042/084/090-A, -W, -G Figure 1. Top piping option Figure 2. Bottom piping option Figure 3. Side diverted front panel option 11.6" 77.8" 42.1" PIPINGCONNECTION POWERCONNECTION AIR OUT AIR IN CONDENSATECONNECTION CONDENSATECONNECTION PIPINGCONNECTIONPOWERCONNECTION 11.6" 77.8" 48.3" 18 AH-PRC014A-EN
  • Media type icon

    AHR-PSD012B-EN_11052025

    5 Ton, Installation, Operation, and Maintenance(AHR-SVX004*-EN). 18 AHR-PSD012B-EN Field Wiring5TEMC can be used in either Link Communicating mode or 24 volt mode. In Link Communicating mode,all configurations are made by using the configuration menu in the User Interface (UX360) or from
  • Media type icon

    TEMP-SVN013A-EN_04262025

    Document Title:Rental Services Electric Heaters
    Publication Type:Installation
    Publication Date:2025-04-26
    -phase 460V, 3-phase Unit MCA 74.4 248.3 235 Motor FLA 3 18 7.6 Unit FLA 56.6 187.5 190 MOP 75 250 250 (a) The 150 kW (F1) heater has two stages of heat and can be used as a 75 kW heater. In this scenario, the unit FLA is 92 amps and MOP is 150 amps. 10 TEMP-SVN013A-EN Unit Controls50 kW and 150 kW (F0
  • Media type icon

    ODR-SVX003D-EN_04172026

    jumper at furnace (if equipped). 3. For +TSTAT, connect W2 to W2 and Y2 to Y2. 4. For Link enabled systems, omit all 24V wiring and use "CAN" connection only.5. X2 is necessary if not using select Trane or American Standard thermostats. Electrical 18 ODR-SVX003D-EN Figure 25. Single-stage, HP, 5TEM6
  • Media type icon

    RLC-PRC020M-EN_06012025

    ) to oil charge value given for B compressor family units. Add 1.0 gal (4L) for all other units. General Data 18 RLC-PRC020M-EN ControlsAdaptiView™ TD7 Operator Interface The standard AdaptiView™ TD7 display provided with the Symbio™ 800 controller features a 7-inchLCD touch-screen, allowing access