Search Results: ED*

Showing 1,011 - 1,020 of 1,478 results

Display results per page.
  • Media type icon

    12134880B_01132025

    Document Title:INTELLICORE CA SCHEMATIC OPTIONAL LOW AMBIENT CONTROLS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2025-01-13
    ) 64E(Y) G/Y 1 2 3 4 62E(BR) 1XP102 1 2 3 24VAC 115VAC 1T7 SPL-88 SPL-89 1KF51 T A MB IEN T C Y1 Y2 RE V V ALV E P1 & P 2 B LK P1 & P 2 R ED P1 B.W .G. P2 B.W .G. LIN E 1 LOA D 1 LIN E 2 LOA D 2 LIN E 3 LOA D 3 HEATPUMP T A MB IEN T N.C. N.O. 5 6 2M6 L1 L2 L3 GND 1 2 3 4 1BT17°t BR OW N BR OW N
  • Media type icon

    RT-PRC096F-EN_02292024

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Electric Heat Standard Efficiency 6 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-02-29
    stringent performancerequirements, and are competitively priced. Trane delivers with Precedent™.Precedent™ features cutting edge technologies: reliable compressors, Trane engineered Symbiocontrols, computer-aided run testing, and Integrated Comfort™ Systems. So, whether you’re thecontractor, the
  • Media type icon

    TEMP-SVX003B-EN_05092025

    RACCES S D OO R ACCES S D OO RACCES S D OO R 991 2 1191 2 211 2 V ICTA ULI C TRU CK B ED(B Y O THER S) 211 2 PIPI NG SU PPO RT TRU CK B EDTI E D OW N ACCES S D OO RACCES S D OO R ACCES S D OO RACCES S D OO R ACCES S D OO R CU T A-A CU T A-A CU T B-B CU T B-B CO NTR OL PAN EL CU T A-A CU T B-B SID E
  • Media type icon

    TEMP-PRC011A-EN_04152025

    EMOV ABLE GLA NDS a. PADL OCKA BLE DOOR 5.HA RDW IRE ACCE SS6. CAGE WIT H FO RKLIF T PO CKET S7. 10" F OAM FILL ED T IRES FOR POR TABI LITY 8. TEMP-PRC011A-EN5 Vertical I-Line Panel 1200A RSIP1200S0 and RSIP1200J0 General Information • I-line interior rated for 600 V • UL50 listed • NEMA 3R • 65 KAIC
  • Media type icon

    AC-SVX004D-EN_05162025

    100 Active Demand Limit Setpoint (%) Num ber of a llow ed c ompre ssor s(6 com pre ssor s unit) EDLS and ECHWS Analog Input SignalWiringBoth the ECHWS and EDLS can be connected and setupas either a 2-10 VDC (factory default), 4-20 mA, orresistance input (also a form of 4-20mA) as indicatedbelow
  • Media type icon

    AC-PRC002K-EN_05162025

    . • BACnet®, Modbus®, LonTalk®, communications protocol interface available without the need forgateways. • Optional condenser fan speed control to help meet preset nighttime sound requirements. Improved Serviceability• All major serviceable components are close to the edge. Service shutoff valves and
  • Media type icon

    TEMP-SVX002B-EN_05092025

    , sharp edges, or any other adverseenvironmental effects. Account for the effects of agingor continual vibration from sources such ascompressors or fans. • Capacitors are discharged. This shall be done in a safemanner to avoid possibility of sparking. • No live electrical components and wiring are
  • Media type icon

    PKG-PRC025B-EN_05162025

    will have 80% minimum thermal efficiency and incorporate listed Gas-fired components. The duct furnace models are listed by Intertek Testing Services (ITS/ETL) foroperation on natural or propane gas to the current edition of ANSI Z83.8 Standard for Gas-FiredDuct Furnaces. Duct furnaces are for
  • Media type icon

    ACC-SVN59P-EN_04202020

    Document Title:Precedent™ Packaged Rooftop Units Electric Heaters
    Publication Type:Installation
    Publication Date:2020-04-20
    careful to avoid dragging the heater element on the edges of the opening in vestibule panel, as this could damage or pinch the heater elements resulting in a short circuit. 8. Secure the electric heater element assembly with 6 screws. 9. If necessary, fasten door extension onto heater door with
  • Media type icon

    PKG-SVX028B-EN_05162025

    : 24 V nominal☐ Check fan amp draw and compare to nameplate☐ Check fan rotation: See fan label ☐ Verify correct fan rotationNote: Leading edge of the propeller fan blade should contact the air first☐ Air handler On (all units) ☐ Note the total system current draw☐ Note the motor current draw (burner