Search Results: 18-HE125D1-1C-EN

Showing 1,011 - 1,020 of 7,117 results

Display results per page.
  • Media type icon

    DLR-SVX001A-EN_09012025

    Document Title:Multi Position Air Handler 2-5 Ton
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-09-01
    entrance for the unit is located on both left and right side of the cabinet. See the right or left side view for knockout locations. DLR-SVX001A-EN 5 Units: mm (in.)Model code ③ Nominal filter sizeDuct connection ① Gas pipe② Liquid pipe 5TEM9C02AC21SA 508 x 508 x 25.4(20 x 20 x 1) 477 x 402(18-13/16
  • Media type icon

    BAS-PTS016A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for Series R® Model RTHD
    Publication Type:Points List
    Publication Date:2024-11-15
    Symbio™ 800 Integration Points ListLonTalk®Series R® Model RTHD Date:11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted
  • Media type icon

    ACC-SVN178G-EN_11112021

    attempt to clean mist eliminators with the screws still installed in the outside air damper. This could result in equipment damage. Figure 26. Mist eliminator removal 16 ACC-SVN178G-EN Economizer Controller Notes: • Upon power up or after a power outage or brownout (or if power goes below 18 Vac
  • Media type icon

    ACC-SVN323A-EN_01122025

    Document Title:0 to 100% Standard Economizer –Foundation™ Packaged Rooftop Units Cooling and Gas/Electric 7.5 to 12.5 Tons
    Publication Type:Installation
    Publication Date:2025-01-12
    CO2 sensor is not used). Economizer Controller 12 ACC-SVN323A-EN Figure 11. Potentiometer and LED locations (W7212 shown) CONTROL CURVE A B C D E CONTROL POINT APPROX. °F (°C) AT 50% RH 73 (23) 70 (21) 67 (19) 63 (17) 55 (13) 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 90 100 80 70 60 50 40
  • Media type icon

    TEMP-SVX001A-EN_02142023

    Figure 10. 60T CGAM (CSCA0060F3) TEMP-SVX001A-EN 17 Dimensions and Weights Figure 11. 80T CGAM (CSCA0080F1) 18 TEMP-SVX001A-EN Dimensions and Weights Figure 12. 80T CGAM (CSCA0080F2) TEMP-SVX001A-EN 19 Dimensions and Weights Figure 13. 100T CGAM (CSCA0100F1) 20 TEMP-SVX001A-EN Dimensions and Weights
  • Media type icon

    MXW-SVN15A-EN_06012009

    Document Title:Trane Installation Manual - Split System (R410A) 16 SEER, Inverter Units 9,000 to 24,000 BTU/Hr - Models: Heat Pump 4MXW6 4TXW6 4MXW6 4TXW6
    Publication Type:Installation
    Publication Date:2009-06-01
    Superseded By:MXW-SVN15A-EN
    . All field wiring MUST be performed by qualified personnel. Failure to follow these requirements could result in death or serious injury. Heat Pump High Efficiency 50 Hz models Wiring Diagrams Figure 2. 4TXK6509ABAA (Outdoor) MXW-SVN15A-EN 17 Wiring Diagrams Figure 3. 4MXW6509ABAA (Indoor) 18 MXW
  • Media type icon

    RRU-SVX02F-EN_11012021

    Document Title:Indirect Gas-Fired Dedicated Outdoor Air Rooftop Unit
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-11-01
    Cutoff (Time)S/Air High Cutoff (Temperature) HGRHD HGRH Control Dead Band OSSPOSHOOSRSNHSPNCSPNRSPNSAS Occupied Space CoolingOccupied Space Heating OffsetOccupied Space HumidityUnoccupied Space HeatingUnoccupied Space CoolingUnoccupied Space HumidityUnoccupied S/Air Heating 18 RRU-SVX02F-EN Sequence
  • Media type icon

    PART-SVN23C-EN_06182020

    Document Title:Causes of Compressor Failure — Models CSHS, CSHA, CSHB, CSHC Including Approved Oils for Trane Compressor Model CSHA and Interchangeability of CSHA and CSHS
    Publication Type:Installation
    Publication Date:2020-06-18
    applications. For more information, please visit trane.com or tranetechnologies.com. PART-SVN23C-EN 18 Jun 2020Supersedes PART-SVN23B-EN (Sep 2012) Introduction Causes of Compressor Failure Approved Oils for Trane Compressor Model CSHA and Interchangeability of CSHA and CSHS Compressors Compatibility of Compressor Oils and Affects on the System
  • Media type icon

    ODR-SVX003D-EN_04172026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    jumper at furnace (if equipped). 3. For +TSTAT, connect W2 to W2 and Y2 to Y2. 4. For Link enabled systems, omit all 24V wiring and use "CAN" connection only.5. X2 is necessary if not using select Trane or American Standard thermostats. Electrical 18 ODR-SVX003D-EN Figure 25. Single-stage, HP, 5TEM6
  • Media type icon

    RLC-PRC020M-EN_06012025

    ) to oil charge value given for B compressor family units. Add 1.0 gal (4L) for all other units. General Data 18 RLC-PRC020M-EN ControlsAdaptiView™ TD7 Operator Interface The standard AdaptiView™ TD7 display provided with the Symbio™ 800 controller features a 7-inchLCD touch-screen, allowing access