Search Results: 18-HD83D1-5B-EN

Showing 931 - 940 of 7,121 results

Display results per page.
  • Media type icon

    5071-1304D_08122013

    Document Title:Schematic - CenTraVac - UCP2 Wiring Diagram with Danfoss Adaptive Frequency Drive
    Publication Type:Wiring Diagram or Manual
    Publication Date:2013-08-12
    . BACK & INSULATE SHIELD ON IPC - STRIP NOTE: DO NOT GROUND 24V 2-10 VDC 2K1-29,33 WH T BLK SH IELD 4C 1F 2X1-8 8C 9C 4 5 20 53 55 03 01 12 13 27 18 2U2 2CB1 2CB1 2CB1 RELAY 2 2K1 12 8 2K12 9 5 2K1 9 5 2K2 9 5 2W1 SEE NOTE 1 START RELAY STOP RELAY 2X1-5 P 3S11CB1 RELAY 1 GND DRIVE ENCLOSURE GNDGRN/YEL
  • Media type icon

    CAUK-SVX001B-EN_05082025

    ACCESS 1 1/4" x 4 1/2"SLOT FOR 115V ACCESS DETAIL ACONTROL BOX BOTTOM FRONT (SEE NOTE3 FOR ALL MIN.CLEARANCE) VENTILATION 4 2 4 2 4 4 Dimensions and Weights 18 CAUK-SVX001B-EN Figure 7. Air-cooled condenser connections — 40 ton 5 7/16" 49 13/32" 27 13/32"10 15/32" 41 7/8" 2 7/8"27 11/32" 5 3/4
  • Media type icon

    18-HD54D1-1B-EN_12172020

    Document Title:Trane XR102 Non-Programmable Thermostat TCONT102 Installation and User Guide
    Publication Type:Installation
    Publication Date:2020-12-17
    Pub No. 18-HD54D1-1B-EN Part No. 37-7770002 SEPTEMBER 2020 Trane XR102 Non-Programmable Thermostat ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. These instructions do not cover all
  • Media type icon

    2311-5186E_07012021

    MINIMUM. ALL STANDARD AND OPTIONAL COMPONENTS SHOWN. 1. 2. 3. 4. 5. 6. 7. GENERAL NOTES: NOTICEUSE COPPER CONDUCTORS ONLY! FAILURE TO USE COPPER CONDUCTORSCOULD RESULT IN EQUIPMENT DAMAGEAS THE EQUIPMENT WAS NOT DESIGNEDOR QUALIFIED TO ACCEPT OTHER TYPES AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE
  • Media type icon

    SS-SVN017D-EN_03142026

    capacitance between conductor and shield: < 200 pF/m• Foil or braided shield is acceptable• Wire diameter: 22 to 18 AWG SS-SVN017D-EN 17 Condenser and Air Handler PairingsTable 8. Model number descriptions TWE Air Handler with Symbio Digit 15 — Controls 1 = Constant VolumeC = 2–SpeedD = Single Zone VAV
  • Media type icon

    CDHH-SVX003F-EN_04112026

    366 930 852 2164 38 97 118 300 440M/44HM 120 305 318 808 756 1920 38 97 118 300 18 CDHH-SVX003F-EN Table 5. Clearance requirements (continued) Shell ComboA B C D E in. cm in. cm in. cm in. cm in. cm 440X/44HX 120 305 366 930 852 2164 38 97 118 300 Note: All dimensions are approximate; refer to the
  • Media type icon

    18-4045-01_03012018

    Document Title:Trane Supply 2018 Spring Stock Up Catalog - $35.00 per Package of 10 - SOLD IN PACKAGES OF 10
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2018-03-01
    SPRING STOCK-UP20 18 RIGHT PARTS.RIGHT NOW.RIGHT PARTS.RIGHT NOW. 2018_spring_stockup_coverTS.indd 1 1/29/2018 4:11:25 PM
  • Media type icon

    18-HB13D7-7_06012009

    Document Title:Installer's Guide Supplementary 1400 Series Electric Heaters for Air Handler Installations.
    Publication Type:Installation
    Publication Date:2009-06-01
    control box. 18-HB13D7-7 HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICINGWARNING: 05/09 Page 2 INSTALLER'S GUIDE 18-HB13D7-7 BAYHTR -- HEATER DATA HeaterModel No. Numberof CircuitsPhase 240 VOLT 208 VOLT Capacity HeaterAmps per Circuit Capacity Heater Amps per CircuitKW BTUH KW BTUH BAYHTR1405
  • Media type icon

    18-CH88D1-1_02262021

    Document Title:Installer's Guide KIT17922
    Publication Type:Installation
    Publication Date:2021-03-02
    TO 0 VOLTS. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Sharp Edge Hazard. Be careful of sharp edges on equipment or any cuts made on sheet metal while installing or servicing. Personal injury may result. 18-CH88D1-1 CAUTIONThe IFC is polarity sensitive
  • Media type icon

    18-CH89D1-1_02262021

    Document Title:Installer's Guide KIT17923
    Publication Type:Installation
    Publication Date:2021-03-02
    DISCHARGE TO 0 VOLTS. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. CAUTIONSharp Edge Hazard. Be careful of sharp edges on equipment or any cuts made on sheet metal while installing or servicing. Personal injury may result. 18-CH89D1-1 CAUTIONThe IFC is