Search Results: ED*

Showing 891 - 900 of 1,478 results

Display results per page.
  • Media type icon

    RT-PRC125A-EN_09152024

    Net A B C D Length Width 15 EDK180A 2216 1891 629 513 337 413 55 34 17.5 EDK210A 2221 1896 630 514 338 414 55 34 20 EDK240A 2227 1902 628 495 343 435 54 36 25 EDK300A 2263 1938 640 505 350 444 54 36 (a) Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly.(b
  • Media type icon

    RT-PRC127A-EN_09152024

    Disconnect Switch(c) Table 2. 15 to 25 tons packaged rooftop performance data (gas or electric heat)Nominal Size (Ton) 15 17.5 20 25 EDK180 GDK180 EDK210 GDK210 EDK240 GDK240 EDK300 GDK300Cooling Performance(a) (a) Units are AHRI Certified to AHRI Standard 340-360 (I-P). Rating conditions are 95°F
  • Media type icon

    ACC-SVN303A-EN_09152024

    Document Title:0 to 100% Downflow Dry Bulb Economizer Foundation™ Packaged Cooling and Gas/Electric 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    assembly (Carrier configuration) 1 3 Return air damper assembly 1 4 Connecting rod assembly (Trane option) 1 5 Block-off 1 6 Plastic bag of miscellaneous parts: 1 Screws – Edge protector 2 Installation Instructions 1 Table 2. Factory installed component parts list Qty Description 1 Block-off 1 Plastic
  • Media type icon

    ACC-SVN305A-EN_09152024

    Document Title:Power Exhaust Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    Tons Installation Instructions Model Numbers: Used With: BAYPWRX303* G/EDK180-300A3BAYPWRX304* G/EDK180-300A4BAYPWRX305* G/EDK180-300AW Introduction Read this manual thoroughly before operating or servicing this unit. Warnings, Cautions, and NoticesSafety advisories appear throughout this manual as
  • Media type icon

    ACC-SVN311A-EN_09152024

    Document Title:0-100% Low Leak Economizer - Downflow/Horizontal Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    return damper flange (tie bar mechanism end) aligning with the edge of the flange and running the full width of the damper. See Figure 6, p. 8. i. If barometric relief or power exhaust is not installed, install the return block-off panel to seal off the remainder of the return duct opening. See Figure
  • Media type icon

    ACC-SVN301A-EN_09152024

    Document Title:Accessory Electric Heat Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    heaters - cooling - 60 Hz kW StagesEDK180 NOM. CFM6000 EDK210NOM. CFM 7000 EDK240NOM. CFM 8000 EDK300NOM. CFM 9000 18 1 9.5 – – – 36 2 19.0 16.3 14.2 12.6 54 2 28.5 24.4 21.3 19.0 72 2 – 32.5 28.5 25.3 Table 3. Air temperature rise across electric heaters -cooling - 50 Hz kW StagesEA*180ADNOM. CFM
  • Media type icon

    GOV-SLB019-EN_08262024

    Offers access to cutting-edge technologies & innovative solutions Federal Acquisition Regulation (FAR) Compliant GSA Schedule Federal Government* Building Automation Systems, Intelligent Services, Energy Services, Renewable Energy Solutions, Energy Services Performance Contracting, HVAC Systems,HVAC
  • Media type icon

    ACC-SVN226D-EN_09152024

    Document Title:Roof Curb Precedent™ Packaged Rooftop Units 12.5 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    hung from the curb flanges. It must not be installed over the top edges of the curb. • When the duct is fabricated it should be large enough to cover the openings for the return and supply sides of the unit, but the flanges must be narrow enough to slide down inside the curb. Important: All duct
  • Media type icon

    ACC-SVN73P-EN_09132024

    Document Title:Roof Curb - Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-13
    2353 2028 653 511 399 464 55 37 EDK210A 2221 1896 630 514 338 414 55 34 GDK210A 2394 2069 688 561 369 452 55 34 20 ECC240A 2185 1860 632 484 372 372 55 37 GCC240A 2350 2025 643 512 403 466 55 37 EDK240A 2227 1902 628 495 343 435 54 36 GDK240A 2392 2067 683 538 373 473 54 36 25 ECC300A 2221 1896 644
  • Media type icon

    BAS-PRD027G-EN_09132024

    , points, and alarms. • Configure, edit, and override points. • Manage controller settings and set up expansion modules. • Create configurations and TGP2 programs for VAVs, Trane factory blower coils, fan coils, unit ventilators, generic space controllers, and water source heat pumps. • Balance air valves