Search Results: ED*

Showing 881 - 890 of 1,478 results

Display results per page.
  • Media type icon

    ACC-SVN195E-EN_08232024

    Document Title:Unit Mounted Disconnect - Foundation™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2024-08-23
    DisconnectFoundation™ Packaged Rooftop Units3 to 5 Tons Model Number: Used With:BAYDSCF322* E/GB*036-060****B* E/GD*036-060****B*, Cooling Only/Gas HeatBAYDSCF323* EB*036-060****B* ED*036-060****B*, 5 to 25 kW Electric Heat August 2024 ACC-SVN195E-EN 9 1110 12 8 ©2024 Trane and American Standard have a policy
  • Media type icon

    TEMP-SLB005-EN_08092024

    . Technical Support, Trouble Shooting, 24/7 Emergency Dispatch 800-755-5115 SCAN ME https://www.trane.com/commercial/north-america/us/en/services/rentals.html 1Design Conditions: 95°F Ambient, 80°F EDB, 71°F EWB, 400 CFM/Ton 25 Ton Trane Precedent Heat Pump with Electric Heat Lifting Device
  • Media type icon

    ACC-SVN203E-EN_08232024

    Document Title:0 to 100% Low Leak Economizer — Downflow - Foundation™ Packaged Cooling and Gas/Electric
    Publication Type:Installation
    Publication Date:2024-08-23
    items11 12 13 14 15 16 6 ACC-SVN203E-EN Installation Field Installed Option Economizer and Fresh Air Hood Installation 1. Remove the filter access panel, unit end panel and horizontal return panel. See Figure 3. 2. Assemble economizer onto unit. Align edge of both side of economizer panel flange
  • Media type icon

    ACC-SVN204F-EN_08232024

    Document Title:Barometric Relief Damper - Foundation™ Units With Low Leak Economizer 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    . Remove panels Remove Panel 2. Build the barometric hood assembly as shown in Figure 4:a. Attach 18 to 20 and 21 using two screws each side.b. Place 17 resting on the bottom flanges of 20 and 21.c. Apply gasket 22 to hood assembly aligning with four edges of the assembly.d. Apply foil tape to cover
  • Media type icon

    ACC-SVN205E-EN_08232024

    Document Title:0 to 100% Low Leak Economizer — Horizontal Foundation™ Packaged Cooling and Gas/Electric 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    screws. Figure 3. 3. Install economizer onto unit. Align edge of both sides of the economizer panel flange with LH and RH side post as shown in Figure 4. Economizer should rest on return base pan as shown. WARNINGHazardous Service Procedures!Failure to follow all precautions in this manual and on the
  • Media type icon

    ACC-SVN207D-EN_08232024

    Document Title:Electric Heat — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    3. Air temperature rise across electric heaters (°F) kW Stages 3 Tons940 CFMEB*036A*ED*036A* 4 Tons1280 CFMEB*048A*ED*048A* 5 Tons1640 CFMEB*060A*ED*060A* 4.7 1 12.38 9.29 7.43 7.5 1 19.76 14.82 11.85 10 1 26.34 19.76 15.81 14.4 1 37.93 28.45 22.76 20 2 – 39.51 31.61 25 2 – – 39.51 Notes: 1. For
  • Media type icon

    ACC-SVN251B-EN_08232024

    Document Title:Crankcase Heater — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    ties. Care must be taken to ensure the leads do not come in contact with the compressor discharge line, with any moving parts or any sharp edges. 8. Re-install the control and compressor access panel.9. Re-apply power to the unit. Note: Refer Figure 3 for crankcase heater wiring diagram. Figure 2
  • Media type icon

    ACC-SVN174F-EN_08232024

    Document Title:Evaporator Defrost Control Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    . Where local regulations are more stringent than these policies, those regulations supersede these policies. • Non-Trane personnel should always follow local regulations. General InformationThe evaporator defrost control (EDC or Frostat™) is installed in the evaporator (Indoor) coil face area. Its
  • Media type icon

    ACC-SVN185D-EN_08232024

    Document Title:Evaporator Defrost Control Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    local representative. General Information• The evaporator defrost control (EDC or Frostat™) is installed in the evaporator (Indoor) coil face area. • The EDC should cycle the compressor when the evaporator frosts under low outdoor ambient cooling conditions or low airflow applications. • The EDC
  • Media type icon

    ACC-SVN168G-EN_08232024

    Document Title:Oversized Motor Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    motor securing bolts to 144 to 151 inch pounds (16.3 to 17.1 N-m). Do not attempt to install lead wires until after the motor has been mounted in place. 12.Check alignment of blower sheave and motor sheave using a straight edge, and adjust if necessary. Torque the motor sheave set screw and the fan