Search Results: 18-HE125D1-1C-EN

Showing 861 - 870 of 7,117 results

Display results per page.
  • Media type icon

    18-HE38D11-3B-EN_07062023

    Document Title:Installer’s Guide Through the Base Utilities Curb Extension, Models BAYUTIL101, BAYUTIL102
    Publication Type:Installation
    Publication Date:2023-07-14
    Model:BAYUTIL101BAYUTIL102 Used with:BAYCURB050BAYCURB051 Installer’s GuideThrough the Base Utilities Curb Extension 18-HE38D11-3B-EN Typical Rooftop Installation Installer’s Guide Page 2 GeneralThis Installer's Guide covers the through the curb utilities extensions listed for the 1-1/2 thru 5 ton
  • Media type icon

    RT-PRC109C-EN_07152023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Electric Heat Ultra High Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2023-07-15
    sound power level data in the performancesection. General Data 18 RT-PRC109C-EN Gross Cooling CapacitiesTable 4. Gross cooling capacities — 12.5 tons, ultra high efficiency CFMEnt DB(°F) Entering Wet Bulb (°F) Entering Wet Bulb (°F) Entering Wet Bulb (°F) 61 67 73 61 67 73 61 67 73 MBh SHC MBh SHC
  • Media type icon

    MS-SVX10A-EN_04012007

    Document Title:Installation, Operation, Maintenance MXW / TXK R410A Split System - Wall Unit Heat Pump - Up To 16.9 SEER 9,000 - 18,000 Btu/Hr
    Publication Type:Installation Operation and Maintenance
    Publication Date:2007-04-01
    toachieve the degree of comfort. To turn the unit OFF: With the unit on, locate the manual switchSTOP button. The unit will stop running. MS-SVX10A-EN 15 Care and Maintenance MS-SVX10A-EN 16 Care and Maintenance MS-SVX10A-EN 17 Troubleshooting MS-SVX10A-EN 18 Troubleshooting MS-SVX10A-EN 19
  • Media type icon

    ODR-PSD009B-EN_09202025

    ODR-PSD009B-EN_09202025 September 2025 ODR-PSD009B-EN Split System Cooling5TTR5018A1000A5TTR5024A1000A5TTR5030A1000A/B5TTR5036A1000A/B5TTR5042A1000A/B5TTR5048A1000A/B5TTR5060A1000A/B Note: Graphics in this document are for representation only.Actual model may differ in appearance. Product and
  • Media type icon

    LPCQ-PRC001-EN_01012021

    310 180 60 185 780 40 50 50 65 LPCQ014 50 1860 310 180 60 185 780 40 50 50 65 LPCQ016 50 1860 310 180 60 193 892 40 50 65 65 LPCQ020 50 2170 310 180 60 193 956 50 50 65 65 1. LPCQ003-008 has one outlet, and LPCQ010-020 has two outlets.Note: 18 LPCQ-PRC001-EN Model Size Fan Section L1Coil and
  • Media type icon

    BAS-PRD015C-EN_10272023

    .(55 mm) 1.73 in.(44 mm) 4.00 in.(101.6 mm) 8.50 in. (215.9 mm)12 DIN units (1 DIN unit = 18 mm) BAS-PRD015C-EN 3 ©2023 Trane Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using
  • Media type icon

    88-4YCA4001-1A-EN_01182022

    Document Title:RunTru/Ameristar Installer's Guide Packaged Gas Heating / Electric Cooling Model 4YCA4
    Publication Type:Installation
    Publication Date:2022-01-18
    -EN CCoonnttrrooll WWiirriinngg ((CCllaassss IIII)) Low voltage control wiring should not be run in conduitwith power wiring unless Class 1 wire of proper voltagerating is used. Route the thermostat cable or equivalentsingle leads of No. 18 AWG colored wire from thethermostat subbase terminals
  • Media type icon

    RT-SVX22V-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ — Electric/Electric 3 to 10 Tons – 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    required whenbarometric damper or economizeris installed. 18 RT-SVX22V-EN Dimensions and Weights WARNING Heavy Objects! Failure to follow instructions below or properly lift unit could result in unit dropping and possibly crushing operator/technician which could result in death or serious injury
  • Media type icon

    5719-3840B_11152024

    Document Title:Field Layout, V Units
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-15
    . ACROSS LINE STARTER CIRCUIT 1 15. ACROSS LINE STARTER CIRCUIT 2 16. CHILLED WATER PUMP FAULT (6F1 AND 6F2) 17. EVAP WATER PUMP RUN SIGNAL 18. PHASE PROTECTION INPUT (6K1 AND 6K2) 19. REFER TO CGAM ELECTRICAL SCHEMATIC FOR SPECIFIC CONNECTION 20. INFORMATION AND NOTES PERTAINING TO WIRING INSTALLATION. 21
  • Media type icon

    GMND-SVX01C-EN_07112020

    Document Title:Gas Unit Heater Separated Combustion Indoor Gas-Fired Duct Furnace
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-07-11
    (610 m). 18 GMND-SVX01C-EN Installation: Venting Combustion Air Inlet System and Piping 1. The combustion air system installation must be in accordance with the latest edition of (N.F.P.A. 54) ANSI Z223.1 National Fuel Gas Code. In Canada, installation must be in accordance with CGA-B149.1