Search Results: ED*

Showing 841 - 850 of 1,448 results

Display results per page.
  • Media type icon

    WSHP-SVX016B-EN_09292023

    Document Title:Water Source Heat Pump Axiom™ Rooftop Standard Efficiency 12.5 to 25 Tons 60Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-09-29
    . • Verify correct model, options and voltage from unitnameplate. • Verify that the installation location of the unit willprovide the required clearance for proper operation. • Assemble and install the roof curb (if applicable). Referto the latest edition of the curb installers guide thatships with each
  • Media type icon

    PART-SVN259A-EN_10132023

    Document Title:Human Interface Upgrade Voyager™ 12.5 to 25 Tons, Precedent™ 3 to 10 Tons
    Publication Type:Installation
    Publication Date:2023-10-13
    compartment base floor hole. 8. Insert the TD-5 cord into the J10 connection on the RTRM board, ensuring that the cord is not pulled tight against any sheet metal edges that could cause damage to the cord. 9. Optional: If the RTOM board was purchased, which allows the ability to create the Supply
  • Media type icon

    SO-SVN040A-EN_10132023

    with only the Stop and Run Relays energized. During Starter Dry Run, the control monitors phase current and voltage; If a voltage signal greater than 5V is detected at the board edge of the starter module, or greater than 10% RLA current is detected, the test is terminated immediately and the Dry Run
  • Media type icon

    SO-SVN041A-EN_10132023

    Document Title:STRA - Wye Delta Starter Kit
    Publication Type:Installation
    Publication Date:2023-10-13
    the board edge of the starter module, or greater than 10% RLA current is detected, the test is terminated immediately and the Dry Run Failure diagnostic is generated. References: Service alert 148, CVHE-OM-C, CVHE-CLD-1a, CVHE-SB-32, CVHE-W-8A. SO-SVN041A-EN 19 Starter Dry Run Procedure - CH530
  • Media type icon

    SO-SVG011A-EN_10132023

    Document Title:Agility Drive Panel UPS Replacement
    Publication Type:Installation
    Publication Date:2023-10-13
    1XJ2 -1 1XJ2 -3 1XJ2 -2 120V AC MA XFO R C OM PU TER US E O NLY RE CE PTA CLE 2X10 US B HN G 227B 260B 211K 2X2- 5G ND 260A 2X6- 6 211S 211S HG N FIE LD S UP PLI ED 110 -120 VA CS ER VIC E P OW ER TO 1X J5 INS ET C INS ET C WF8 TO 1 K20 SE RV ICE TO OL LIN E 1 79 224A TO 1 XP 2-4 LIN E 1 55 226A TO 1
  • Media type icon

    SO-SVN043A-EN_10132023

    assure no abrasion is occurring from vibrations against chassis of cabinets, or other edges. 4. Ensure the drive interior and exterior is clear of any dust or debris. Fans, circuit boards, vents, etc. must be clean. Only use a vacuum for cleaning. Do NOT use compressed air. 5. Inspect the interior
  • Media type icon

    SO-SVN044A-EN_10132023

    Document Title:Adaptive Frequency Drive 3 (AFD3) Fan Kit (KIT18925)
    Publication Type:Installation
    Publication Date:2023-10-13
    lexan covers from each drive. 3. Remove the drive chassis sheet metal on the bottom side (output terminal side). There are three screws on the front lower edge and four screws on the bottom side. Figure 5. Removing drive chassis sheet 4. Install the replacement drive chassis sheet metal with fans. 5
  • Media type icon

    SO-SVN048A-EN_10132023

    against chassis of cabinets, or other edges. 4. Ensure the drive interior and exterior is clear of any dust or debris. Fans, circuit boards, vents, etc. must be clean. Only use a vacuum for cleaning. Do NOT use compressed air. 5. Inspect the interior of the drive for any signs of moisture entry or
  • Media type icon

    SO-SVN050A-EN_10132023

    Document Title:Field Installed Louvers and Coil Protection RTAC
    Publication Type:Installation
    Publication Date:2023-10-13
    clips (Figure 1) along the top edge of the coil box. Use 3 clips per panel. Important: The panels at the rear of the unit must be installed first. If the panels are not installed back to front fit up problems will occur. Figure 1. Clips Figure 2. Clips installed 2. Hang panel from fender clips and
  • Media type icon

    SO-SVU001A-EN_10132023

    wire cables and devices to assure no abrasion is occurring from vibrations against chassis of cabinets, or other edges. 5. Ensure the drive interior and exterior is clear of any dust or debris. Fans, circuit boards, vents etc. must be clean. Only use a vacuum for cleaning. Do NOT use compressed air