Search Results: TEMP-SVX005C-EN

Showing 71 - 80 of 7,117 results

Display results per page.
  • Media type icon

    ODR-SVX002A-EN_04062025

    Document Title:RunTru/Ameristar Installation and Operation Manual – Condensing Units A5AC4018A - 060A
    Publication Type:Installation
    Publication Date:2025-04-06
    Suction Gauge Pressure = __________ PSIG 16 ODR-SVX002A-EN Indoor Wet Bulb Temp (F) Outdoor Dry Bulb Temp.(F) 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 55 7 9 10 11 12 14 15 17 18 20 21 23 24 26 27 29 30 60 5 7 8 9 10 12 13 15 16 18 19 21 22 24 25 27 28 30 31
  • Media type icon

    BAS-PTS016A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for Series R® Model RTHD
    Publication Type:Points List
    Publication Date:2024-11-15
    Symbio™ 800 Integration Points ListLonTalk®Series R® Model RTHD Date:11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted
  • Media type icon

    MCX6-PRC804-EN_11011998

    Document Title:Stylus Mini-Split System Air Conditioning, 1 - 5 Tons Convertible Models, 60 Hz. Models- MCX512E1, MCX518E1, MCX524E1, MCX536E1, MCX042E1, MCX048E1, MCX060E1
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:1998-11-01
    Rating Conditions of 80/67 & 95 FGROSS CAPACITY: 14.8 MBHAIRFLOW: 400 CFMSYSTEM POWER: 1779 WATTSNOM. SYSTEM AMPS: 8.2 AMPS English Units 21MCX6-PRC804-EN PerformanceDataCooling TTB012C100A WITH MCX512E1AT 680 CMH GROSS CAPACITY IN KILOWATTSO.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR.D.B
  • Media type icon

    ODR-SVX004C-EN_09192025

    5682 0.38 105.00 40.56 5079 0.35 110.00 43.33 4548 0.31 ODR-SVX004C-EN 25 Table 13. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079 0.28 120.00 48.89 3665 0.26 125.00 51.67 3298 0.23 130.00 54.44 2972 0.21 135.00 57.22 2683 0.19Example
  • Media type icon

    BAS-PTS031A-EN_12062024

    Document Title:Symbio™ 800 Integration Points List BACnet® for RTAC (CH530)
    Publication Type:Points List
    Publication Date:2024-12-06
    Symbio™ 800 Integration Points ListBACnet®RTAC (CH530) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and
  • Media type icon

    BAS-SVN028L-EN_08062022

    Document Title:Trane® Commercial Touch Screen Programmable Zone Sensor for ReliaTel™, UC400 and Symbio™ 400/700/800 Controls
    Publication Type:Installation
    Publication Date:2022-08-06
    wired to HVAC equipment. Important: Configure the Temp Sensor parameter as needed. See 2/4 Configuration menu for details. BAS-SVN028L-EN 7 Zone Sensor Wiring ReliaTel™ SystemsThe zone sensor and the BCI-R form a two-node BACnet MS/TP network. Wire the system as shown in the schematic below while
  • Media type icon

    BAS-SVP085B-EN_11152024

    Document Title:BACnet® and Modbus ™ Integration
    Publication Type:Integration Guide
    Publication Date:2024-11-15
    . If the Heat Cool Mode Status is Cool then the Symbio™ 700 controller will use the Space Temp Cooling Setpoint Status.7. If the Heat Cool Mode Status is Heat then the Symbio™ 700 controller will use the Space Temp Heating Setpoint Status. Appendix A: Arbitrations 24 BAS-SVP085B-EN Space Temperature
  • Media type icon

    BAS-SVP047B-EN_09092023

    Document Title:BACnet® and Modbus™ Integration to Agility™ Water-Cooled Chillers with Symbio™ Controls
    Publication Type:Integration Guide
    Publication Date:2023-09-09
    Water Pressure 0 = Normal1 = In Alarm BI-11067 Diagnostic: Evaporator Leaving Water Temp Sensor 0 = Normal1 = In Alarm BACnet Points List BAS-SVP047B-EN 21 Table 4. Binary input diagnostics (continued) Object Identifier Object Name Object States BI-11068 Diagnostic: Evaporator Water Flow
  • Media type icon

    88-A5AC5001-1B-EN_10172024

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-10-17
    operating conditions (indoor/outdoor temperatures) are not in range to verify with the subcooling charging method. 88-A5AC5001-1B-EN 14.4 Weigh-In Method for Charging Indoor Wet Bulb Temp (F) Outdoor Dry Bulb Temp.(F) 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 55
  • Media type icon

    MCX5-PRC804-EN_11011998

    Document Title:Stylus Mini-Split System Air Conditioning, 1 - 5 Tons Convertible Models, 50 Hz. Models- MCX512EB, MCX518EB, MCX524EB, MCX536EB, MCX042EB, MCX048EB, MCX060EB (Indoor Units)
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:1998-11-01
    MCX5-PRC804-EN PerformanceDataCooling TTB515CA WITH MCX518EBAT 475 CFM GROSS CAPACITY IN BTU/H x 1000O.D. I.D. TOTAL SENS. CAP. AT ENTERING D.B. TEMP. COMPR. DEWD.B. W.B. CAP. 72 74 76 78 80 KW DEW PT. 59 13.4 12.0 12.9 13.6* 14.0* 14.3* 1.01 48.685 63 14.6 10.2 11.1 12.1 13.0 14.0 1.05 52.3 67 15.8