    MCD5-MAIR03-EN_11012004

    Document Title:Illusion Split System - Split System Air Conditioning (Concealed Type) 1-5 Ton - 50 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2004-11-01
    0.66 0.61 0.52 0.44 0.36* 0.27 0.1HIGH 0.72 0.68 0.61 0.53 0.49 0.43 0.35 0.24 0.18*- PerformanceData 15 Indoor Fan Performance Table Fan coil Airflow (CFM) versus. External Static Pressure (in.wg) O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 61 11.2 7.9
  • Media type icon

    57325333_A_10112023

    Document Title:Diagram; Unit Component Location, ACR, 2 Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-10-11
    - COMPRESSOR 2A 6BT1SENSOR; MOTOR WINDING TEMP 1 - COMP. 2A 6BT2SENSOR; MOTOR WINDING TEMP 2 - COMP. 2A 6BP3SENSOR; SUCTION - COMPRESSOR 2A 6QM3MOTOR; OIL RETURN VALVE - COMPRESSOR 2A 6QM1MOTOR; EXPANSION VALVE 1 CKT 2 6E3HEATER; OIL SEPARATOR - CKT 2 5E1HEATER; IMMERSION HEATER - COMP. 1A 6BP4SENSOR
  • Media type icon

    18-HE110D1-1A-EN_05012018

    Document Title:Envirowise Dehumidifier & Ventilation System Controller D30, D30R
    Publication Type:Installation
    Publication Date:2018-05-01
    INSTALLER’S & OWNER’S MANUALHVAC INSTALLER: PLEASE LEAVE MANUAL FOR HOMEOWNER Dehumidifi er & Ventilation System Controller D30D30R Part No. E4037893 18-HE110D1-1A-EN TS-994 Rev. 2 5/24/18 Table of Contents1. Specifi cations ............................................................ 22
  • Media type icon

    23116153_A_03272023

    Document Title:WSHP Schematic Diagram GE/EX/DX UC400-B E-Heat Ready ECM - Single Phase
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    62B1S1 HIGH PRESSURE CUTOUT 372B1S2 LOW PRESSURE CUTOUT 372CCH-1 CRANKCASE HEATER 32L1 REVERSING VALVE COIL 342V1 WATER ISOLATION VALVE 283B2 EVAP FAN MOTOR (ECM) 133RT6 DISCHARGE AIR TEMP 463S2 FROSTAT 323S3 CONDENSATE OVERFLOW 434RT2 ENTERING WATER TEMP SENSOR 314RT3 LEAVING WATER TEMP SENSOR 296V1
  • Media type icon

    23116154_A_03272023

    Document Title:WSHP Schematic Diagram GE/EX/DX UC400-B E-Heat Ready ECM - Three Phase
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    PRESSURE CUTOUT 372L1 REVERSING VALVE COIL 342V1 WATER ISOLATION VALVE 283B2 EVAP FAN MOTOR (ECM) 9,133RT6 DISCHARGE AIR TEMP 463S2 FROSTAT 323S3 CONDENSATE OVERFLOW 434RT2 ENTERING WATER TEMP SENSOR 314RT3 LEAVING WATER TEMP SENSOR 296V1 WATERSIDE ECONIMIZER VALVE 38WCI WCI MODULE 18 WARNING
  • Media type icon

    CG-PRC002E-EN_07012012

    Document Title:CGAD Liquid Chillers - Air-Cooled Scroll Compressor 20 to 150 Tons - Models- 50 and 60 Hz / Product Catalog / Sourced in Brazil
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2012-07-01
    Product Catalogue CG-PRC002E-ENJuly 2012 CGAD Liquid ChillersAir-CooledScroll Compressor20 to 150 Tons Models: 50 / 60 Hz CGAD020 CGAD040 CGAD070 CGAD100CGAD025 CGAD050 CGAD080 CGAD120CGAD030 CGAD060 CGAD090 CGAD150 2 CG-PRC002E-EN Introduction CGADAir-Cooled Liquid ChillersDesigned for great
  • Media type icon

    231158610001_08152021

    Document Title:UC400B CONTROLS w/ECM MOTOR, SINGLE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-15
    REVERSING VALVE COIL 342L2 HOT GAS REHEAT 382V1 WATER ISOLATION VALVE 283B2 EVAP FAN MOTOR (ECM) 133RT6 DISCHARGE AIR TEMP 463S2 FROSTAT 323S3 CONDENSATE OVERFLOW 434RT2 ENTERING WATER TEMP SENSOR 314RT3 LEAVING WATER TEMP SENSOR 296V1 WATERSIDE ECONIMIZER VALVE 38CCHR CRANK CASE HEATER RELAY 2,34WCI WCI
  • Media type icon

    23115862D_01052024

    Document Title:WSHP Schematic - GE/EX/DX 400-B ECM 3PH
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-01-05
    REVERSING VALVE COIL 342L2 HOT GAS REHEAT 382V1 WATER ISOLATION VALVE 283B2 EVAP FAN MOTOR (ECM) 9,133RT6 DISCHARGE AIR TEMP 463S2 FROSTAT 323S3 CONDENSATE OVERFLOW 434RT2 ENTERING WATER TEMP SENSOR 314RT3 LEAVING WATER TEMP SENSOR 296V1 WATERSIDE ECONIMIZER VALVE 38WCI WCI MODULE 18 WARNING DISCONNECT
  • Media type icon

    2309-4870H_02242022

    TEMP SENSOR ELECTRONICS IS FACTORY MOUNTED INSIDE THE CONTROL PANEL AND THE IPC BUS ISFACTORY WIRED. THE SENSOR IS TO BE FIELD WIRED EXTERNALLY WITH THE SENSOR LEADS EXTENDED BACK TO THE CONTROLPANEL. THESE WIRES CAN BE SPLICED WITH TWO 14-18 AWG 600V WIRES, WITH A MAXIMUM LENGTH OF 1000 FEET (305
  • Media type icon

    5071-2733B_10102021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Double Door
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-10-10
    SHX Text EN CUIVRE! AutoCAD SHX Text DISE袮DAS PARA ACEPTAR OTROS TIPOS AutoCAD SHX Text LAS TERMINALES DE LA UNIDAD NO EST罭 AutoCAD SHX Text TILICE 贜ICAMENTE CONDUCTORES AutoCAD SHX Text SI NO LO HACE, PUEDE OCASIONAR AutoCAD SHX Text 50712733-B AutoCAD SHX Text DA袿 AL EQUIPO. AutoCAD SHX Text DE