    SS-SVX091D-EN_02262026

    when the outdoor airtemperature is favorable. The cooling capability of the Operating Principles SS-SVX091D-EN 83 outdoor air is determined by comparing the Outdoor AirTemperature against the user adjustable Econ EnableMinimum Outdoor Air Temp Setpoint (60°F). There must bea valid Outdoor Air
  • Media type icon

    1213-4851B_09112024

    2 24 VAC IN COMPRESSOR 2 RUNCOMPRESSOR 2 UNLOADER/CCH NOT USED24 VAC-P OUT CIRCUIT 3 PROVING INCOMPRESSOR 3 24 VAC IN COMPRESSOR 3 RUNCOMPRESSOR 3 UNLOADER/CCH SOV1 OUT (24 VAC-S)GND-S SOV2 OUT (24 VAC-S)GND-S COMMONECM CONDENSER FAN CONTROL DISCHARGE AIR TEMP OUTDOOR AIRTEMP COIL TEMP 1 COIL TEMP
  • Media type icon

    18-HD29D3-4_05012008

    Document Title:Trane Installer's Guide XR402 Model TCONT402AN32DA - 3 Heat (Gas, Oil* or Elec) / 2 Cool / Heat Pump (Factory set for 2H/2C gas/cooling applications, BK Output enabled) Electronic Non-Programmable 3 - 16 Wire Hookup (2 for Outdoor Sensor) (2 for Optional Remote Indoor Sensor, 2 for Optional Humidistat)
    Publication Type:Installation
    Publication Date:2008-05-01
    Y2 CO OL ING -2n d VS MO DE -fa n BK H2 Hu mid ista t H1 Hu mid ista t Outdoor Temp OT1 Outdoor Temp OT2 RS2Remote Indoor Sensor RS1Remote Indoor Sensor Fan ModeFilter/OD $ 4 Pub. No. 18-HD29D3-4 Installer’s GuidePress Fan to return to the previous step. Use the Up and Down arrow buttons to select
  • Media type icon

    5071-2753B_10102021

    ! DAMAGE TO THE EQUIPMENT. N'UTILISER QUE DES CONDUCTEURS PAS CON荱ES POUR RECEVOIR D'AUTRES L'UTILISATION DE TOUT AUTRE CONDUCTEUR LES BORNES DE L'UNITÉ NE SONT TYPES DE CONDUCTEURS. EN CUIVRE! ATTENTION PEUT ENDOMMAGER L'蒕UIPEMENT. SI NO LO HACE, PUEDE OCASIONAR TILICE 贜ICAMENTE CONDUCTORES LAS
  • Media type icon

    5071-2755B_10102021

    ! DAMAGE TO THE EQUIPMENT. N'UTILISER QUE DES CONDUCTEURS PAS CON荱ES POUR RECEVOIR D'AUTRES L'UTILISATION DE TOUT AUTRE CONDUCTEUR LES BORNES DE L'UNITÉ NE SONT TYPES DE CONDUCTEURS. EN CUIVRE! ATTENTION PEUT ENDOMMAGER L'蒕UIPEMENT. SI NO LO HACE, PUEDE OCASIONAR TILICE 贜ICAMENTE CONDUCTORES LAS
  • Media type icon

    2311-1976C_03092022

    WITH FLOW SWITCHES. WHEN ORDERED THE OUTDOOR AIR TEMP SENSOR ELECTRONICS IS FACTORY MOUNTED INSIDE THE CONTROL PANEL AND THE IPC BUS ISFACTORY WIRED. THE SENSOR IS TO BE FIELD WIRED EXTERNALLY WITH THE SENSOR LEADS EXTENDED BACK TO THE CONTROLPANEL. THESE WIRES CAN BE SPLICED WITH TWO 14-18 AWG 600V
  • Media type icon

    MC-SVN002A-EN_04072021

    Document Title:Two-pipe Four-way Cassette
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-04-09
    proprietary Trane information January 2021 FWC0062NF0AL FWC0082NF0AL FWC0092NF0ALFWC0102NF0AL FWC0122NF0AL FWC0152NF0AL MC-SVN002A-EN irjeqv Stamp Two-pipe Four-way Cassette DC Fan Coil Unit 1. External Appearance ............................................................... 3 2. Features
  • Media type icon

    1213-2836C

    Document Title:INTELLIPAK DIAGRAM SCHEMATIC - ELECTRIC HEAT 30KW - 200V / 230V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2018-08-22
    B 17,18,19,473QA31 CONTACTOR - BACK-UP 13,14,453QA32 CONTACTOR - BACK-UP 17,18,473QB4 MANUAL DISCONNECT - ELEC HEAT 103S10 HIGH TEMP LIMIT - MANUAL RESET 433S11 HIGH TEMP LIMIT - AUTO RESET #1 423S12 HIGH TEMP LIMIT - AUTO RESET #2 423S13 HIGH TEMP LIMIT - AUTO RESET #3 42 3XD16 TERMINAL BLOCK
  • Media type icon

    18-GJ59D1-2_11012012

    Document Title:Installer's Guide - RS-485 Replacement Board Model: CNT06197.
    Publication Type:Installation
    Publication Date:2012-11-01
    BAYWACC08 w/*AM7A0C60, BAYWACC08 w/*AM7A0C60BAYWACC08 w/TAMGA0C60 ON ON OFF BAYWACC11SC1A w/*AM7A0C60 BAYWACC11SC1A w/*AM7A0C60BAYWACC11SC1A w/TAMGA0C60 ON ON ON * May be "A" or "T" HHCFault LED Description OFF No fault1 Internal communication error2 Water temp is at 38F or lower3 Water temp sensor
  • Media type icon

    2311-4166C_10112022

    Document Title:Vertical Unit Vent
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-10-11
    -2 AutoCAD SHX Text 24VAC J1-1 AutoCAD SHX Text COMM - J13-4 AutoCAD SHX Text COMM + J13-3 AutoCAD SHX Text TEMP SENSOR AIP1 J1-6 AutoCAD SHX Text 149 AutoCAD SHX Text 219 AutoCAD SHX Text 217 AutoCAD SHX Text 218 AutoCAD SHX Text 215 AutoCAD SHX Text 216 AutoCAD SHX Text 212 AutoCAD SHX Text 213