    12132846B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 90KW - 480V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    CONTACTOR - HEAT CIRCUIT B 4393QA27 CONTACTOR - HEAT CIRCUIT C 4433QA27 CONTACTOR - HEAT CIRCUIT C 4703QA31 CONTACTOR - BACK-UP 4673QA31 CONTACTOR - BACK-UP 4363QA32 CONTACTOR - BACK-UP 4393QA32 CONTACTOR - BACK-UP 4693QA33 CONTACTOR - BACK-UP 4433QA33 CONTACTOR - BACK-UP 4703S10 HIGH TEMP LIMIT
  • Media type icon

    ACC-SVN269E-EN_03302026

    Document Title:LP Conversion Kit Precedent™ Packaged Rooftop Units
    Publication Type:Installation
    Publication Date:2026-03-30
    ACC-SVN26E-EN LP Conversion Kit SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipmentcan be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    1213-2981C_02282020

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 74CC1 COMPRESSOR CONTACTOR 1 90CC1 (AUX2) CC1 AUX 2 NO 81CC2 COMPRESSOR CONTACTOR 2 92CC2 (AUX2) CC2 AUX 2 NO 83CUS1 COMPRESSOR 1 UNLOADING SOLENOID 116CUS2 COMPRESSOR 2 UNLOADING SOLENOID 116DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE TEMP
  • Media type icon

    1213-2979C_02282020

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 74CC1 COMPRESSOR CONTACTOR 1 90CC1 (AUX2) CC1 AUX 2 NO 81CC2 COMPRESSOR CONTACTOR 2 92CC2 (AUX2) CC2 AUX 2 NO 82DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE TEMP LIMIT 2 98HPC1 HIGH PRESSURE CUTOUT 1 100HPC2 HIGH PRESSURE CUTOUT 2 96LPC1 LOW
  • Media type icon

    PKGR-SVX004D-EN_04182026

    Document Title:Installation and Operations Manual - Single Packaged Gas/Electric, Choice, Convertible, 2 - 5 Ton, R-454B, 5YCC4
    Publication Type:Installation
    Publication Date:2026-04-18
    -EN Single Packaged Gas/ElectricChoice, Convertible, 2 to 5 Ton, R
  • Media type icon

    18-HD45D1-7_04012016

    Document Title:Installation and User Guide Touchscreen Comfort Control TCONT624AS42DA
    Publication Type:Installation
    Publication Date:2016-04-01
    terminals)- None- Replaces internal sensor- Average with internal sensorOutdoor Temp Sensor (connect to the ODT terminals)- None- OutdoorCaution: Do not run sensor wires in the same bundle with HVAC wires. Keep away from high voltage wiring to avoid interference. Remote Tempurature Sensor Connections and
  • Media type icon

    1213-4768A_07192023

    Document Title:ODYSSEY SCHEMATIC CONTROLS, COOLING CONDENSER DUAL COMPRESSOR (FIXED & MANIFOLDED) DUAL FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-07-19
    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 27 CC1 COMPRESSOR CONTACTOR 1 29CC1 (AUX2) CC1 AUX2 NO 20 CC2 COMPRESSOR CONTACTOR 2 31CC2 (AUX2) CC2 AUX2 NO 21 DTL1 DISCHARGE LINE TEMP LIMIT 1 41DTL2 DISCHARGE LINE TEMP LIMIT 2 37HPC1 HIGH PRESSURE CUTOUT 1 39HPC2 HIGH PRESSURE CUTOUT 2 35LCI LONTALK
  • Media type icon

    1213-2978C_02282020

    REF DES DESCRIPTION LINE NOCC1 COMPRESSOR CONTACTOR 1 90CC1 (AUX2) CC1 AUX 2 NO 81CC2 COMPRESSOR CONTACTOR 2 92CC2 (AUX2) CC2 AUX 2 NO 82DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE TEMP LIMIT 2 98HPC1 HIGH PRESSURE CUTOUT 1 100HPC2 HIGH PRESSURE CUTOUT 2 96LPC1 LOW PRESSURE CUTOUT 1
  • Media type icon

    1213-2980B_12112019

    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 74 CC1 (AUX2) CC1 AUX 2 NO 81CC2 (AUX 2) CC2 AUX 2 NO 83 CC1 COMPRESSOR CONTACTOR 1 89CC2 COMPRESSOR CONTACTOR 2 92 CUS1 COMPRESSOR 1 UNLOADING SOLENOID 116CUS2 COMPRESSOR 2 UNLOADING SOLENOID 116DTL1 DISCHARGE LINE TEMP LIMIT 1 102DTL2 DISCHARGE LINE
  • Media type icon

    12134771_A_08092023

    Document Title:Control Schematic (Wiring Diagram) for units with Single compressor and Single Fan
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-08-09
    REF DES DESCRIPTION LINE NOAB ADAPTER BOARD 27 CC1 COMPRESSOR CONTACTOR 1 29CC1 (AUX2) CC1 AUX2 NO 20 CTS1 COIL TEMP SENSOR 1 27DTL1 DISCHARGE LINE TEMP LIMIT 1 41HPC1 HIGH PRESSURE CUTOUT 1 39LCI LONTALK COMMUNICATION INTERFACE 5 LPC1 LOW PRESSURE CUTOUT 1 33OAS OUTDOOR AIR SENSOR 25OFC1 OUTDOOR