Search Results: TEMP-PRC013A-EN

Showing 551 - 560 of 7,116 results

Display results per page.
  • Media type icon

    AHU-SLB002-EN_04302020

    Document Title:Low Temp AHU / Rental Services
    Publication Type:Sales Brochure
    Publication Date:2020-04-30
    Low Temp AHU WatersideOur low-temp air handling units are specifically designed for cooler, freezer type applications where there is a requirement for air temperatures below 32°F. Multiple AHU ApplicationsIn order to prevent a decrease in airflow supply due to excessive frozen coils, the unit
  • Media type icon

    12132842B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 30KW - 480V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    CONTROLS 4513KF31 HEAT CONTROLS 4673QA25 CONTACTOR - HEAT CIRCUIT A 4343QA25 CONTACTOR - HEAT CIRCUIT A 4673QA31 CONTACTOR - BACK-UP 4343QA31 CONTACTOR - BACK-UP 4673QB4 MANUAL DISCONNECT - ELEC HEAT 4243S10 HIGH TEMP LIMIT - MANUAL RESET 4663S11 HIGH TEMP LIMIT - AUTO RESET #1 4653S12 HIGH TEMP
  • Media type icon

    22-1859-07_02012018

    SPECIFICATIONS 1MODELTYPERATINGS 2Input BTUH 3Capacity BTUH (ICS) 3AFUE (Upflow / Horizontal)Temp. rise (Min.-Max.) °F.BLOWER DRIVE 5Diameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts / Ph / HzFLACOMBUSTION FAN — TypeDrive - No. SpeedsMotor HP - RPMVolts / Ph / HzFLAFILTER
  • Media type icon

    12134933D_06062025

    FUSED SWITCH - CONVENIENCE OUTLET 7662T4 TRANSFORMER - CONVENIENCE OUTLET 7392T4 TRANSFORMER - CONVENIENCE OUTLET 7552XJ1 CONVENIENCE OUTLET 7642Y1 ANTENNA, WI-FI 7574BT2 SENSOR - SUPPLY AIR TEMP 7394BT4 SENSOR - CIRCUIT #1 EVAP SUCTION TEMP #1 7394BT6 SENSOR - CIRCUIT #2 EVAP SUCTION TEMP #1
  • Media type icon

    UN-SLB032-EN_12062023

    Document Title:Packaged and Split System Heat Pumps FAQs
    Publication Type:Sales Brochure
    Publication Date:2023-12-06
    and split system heat pumps, visit trane.com or contact your Trane Account Manager. 75 65 55 45 35 25 15 5 -5 -15 OD Coil Temp 12 Min Timer Starts 12 Min After Coil Temp Below 33F DefrostTerminate Temp Termination ofDefrost Cycle OD Air Defrost Permit Temp OD Air Temp OD Coil Defrost Permit TempIce
  • Media type icon

    GTNE-SVN002C-EN_08212020

    Document Title:Four-Inch Combustion Air Inlet Kit Tubular Gas-Fired Direct Spark Propeller Unit Heaters Category III Venting for Separated Combustion for 30,000 to 75,000 Btu/h
    Publication Type:Installation
    Publication Date:2020-08-21
    GTNE-SVN002B-EN (06 Jul 2015): Installation Instructions - Four-Inch Combustion Air Inlet Kit - Tubular Gas-Fired Direct Spark Propeller Unit Heaters - Unit Conversion and Category III Venting for Separated Combustion for 20,000 to 75,000 Btu/h Four-Inch Combustion Air Inlet KitTubular Gas-Fired
  • Media type icon

    12132844B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 30KW - 208V/240V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    -UP 4353QA31 CONTACTOR - BACK-UP 4673QA32 CONTACTOR - BACK-UP 4693QA32 CONTACTOR - BACK-UP 4383S10 HIGH TEMP LIMIT - MANUAL RESET 4663S11 HIGH TEMP LIMIT - AUTO RESET #1 4653S12 HIGH TEMP LIMIT - AUTO RESET #2 4653S13 HIGH TEMP LIMIT - AUTO RESET #3 4653XD5 TERMINAL BLOCK 4283XD16 TERM BLOCK - 115 VAC
  • Media type icon

    12132843B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 30KW - 208V/240V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    4353QA32 CONTACTOR - BACK-UP 4693S10 HIGH TEMP LIMIT - MANUAL RESET 4663S11 HIGH TEMP LIMIT - AUTO RESET #1 4653S12 HIGH TEMP LIMIT - AUTO RESET #2 4653S13 HIGH TEMP LIMIT - AUTO RESET #3 4653XD5 TERMINAL BLOCK 4253XD16 TERM BLOCK - 115 VAC 4653XD17 TERM BLOCK - 115 VAC COM 4663XD20 TERMINAL BLOCK
  • Media type icon

    ACC-SVN118H-EN_04272020

    Document Title:Head Pressure Control Kit Odyssey Split-System Cooling and Heat Pumps 6-25 Tons
    Publication Type:Installation
    Publication Date:2020-04-27
    , TWA061E/073E/076E/090E,TWA0604*D/0724*D/0764*D/0904*D/101/120/156/180/201/240 ©2020 ACC-SVN118H-EN IntroductionRead this manual thoroughly before operating orservicing this unit. Warnings, Cautions, and NoticesSafety advisories appear throughout this manual asrequired. Your personal safety and the
  • Media type icon

    BAS-SVP044C-EN_10122025

    Document Title:Trane® Mitsubishi Electric VRF Integration License for the Tracer® SC+ System Controller
    Publication Type:Integration Guide
    Publication Date:2025-10-12
    . Improperly installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 BAS-SVP044C-EN Integration