Search Results: AC-SVX003D-EN

Showing 51 - 60 of 7,121 results

Display results per page.
  • Media type icon

    18-HD70D1-2_08012011

    Document Title:Installation Guide Modulating Zone Dampers
    Publication Type:Installation
    Publication Date:2011-08-01
    MANUALGEARRELEASE !Class2Supply CLOSED OPEN COM PO PC EwC Exc elle nce With out C ompr imis e CO NTR OS I MA -ND 4 24 V AC 50/ 60H z1. 5VA 1W 18 in -lb (2 Nm )35 s MA NU AL GE AR RE LEA SE !C lass 2S uppl y CLO SE D OP EN 2 18-HD70D1-2 Verify damper model. Verify damper size and net free area. Using the
  • Media type icon

    ODR-SVX028A-EN_03202026

    connect BK.Notes: • BK dehumidification reduces indoor airflowwhen active. • AC models do not require O at the outdoor.• Use wire nuts for all pigtail connections and cap all unused wires. Electrical 18 ODR-SVX028A-EN Mitigation Board Guidelines• The approved ID/OD combination will provide sufficient
  • Media type icon

    ODR-SVX013B-EN_04172026

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    control, cut BK jumper on the AFC and connect BK fromcomfort control to BK of the air handler. ODR-SVX013B-EN 17 Figure 23. AC with furnace and variable speed furnace With Furnace Thermostat Evaporator Coil MCBOutdoor UnitFurnace R G B R G B B R G B/C Y W1 W2 24 VAC HOT FAN 24 VAC Common COOL HEATING BK
  • Media type icon

    RTHC-SVN02C-EN_05012003

    Document Title:Installation RTHC Condenser Water Regulating Valve Option
    Publication Type:Installation
    Publication Date:2003-05-01
    applications but are field adjustable if required. Refer to Figure 3. Figure 3 Valve Actuator 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 OPEN STOP CLOSE DIRECTACTION REVERSEACTION + - -+INPUT AC xxx V OUTPUT + + + + + + 1 2 3 1 2 3 ZeroSpan Sensitivity 6 RTHC-SVN02C-EN
  • Media type icon

    RTHC-SVN02C-EN_05012003

    Document Title:Installation RTHC Condenser Water Regulating Valve Option
    Publication Type:Installation
    Publication Date:2003-05-01
    applications but are field adjustable if required. Refer to Figure 3. Figure 3 Valve Actuator 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 OPEN STOP CLOSE DIRECTACTION REVERSEACTION + - -+INPUT AC xxx V OUTPUT + + + + + + 1 2 3 1 2 3 ZeroSpan Sensitivity 6 RTHC-SVN02C-EN
  • Media type icon

    ODR-SVX002C-EN_04172026

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    dehumidification reduces indoor airflowwhen active. • AC models do not require O at the outdoor.• Use wire nuts for all pigtail connections and cap all unused wires. Electrical 18 ODR-SVX002C-EN Mitigation Board Guidelines• The approved ID/OD combination will provide sufficient safe ventilation in
  • Media type icon

    BAS-SVN040B-EN_05012020

    )conduit (for AC wiring) 2.25 in (56 mm)14.75 in (373 mm) Knockout for .75 in (19 mm) conduit Knockout for 50 in(13 mm) conduit 3.125 in (80 mm) 16.5 in)))mm(418 mmmm) 5.5 in(140 mm) 13.25 in (337 mm) BAS-SVN040B-EN 11 Installation Location and Mounting Guidelines Location The location should meet
  • Media type icon

    18-AC95D1-5C-EN_11052020

    Document Title:Installer's Guide - Condensing Units - 4TTX8
    Publication Type:Installation
    Publication Date:2020-11-05
    18-AC95D1-5C-EN ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. Condensing Units These instructions do not cover all
  • Media type icon

    BAS-SVN232B-EN_09092022

    BAS-SVN232A-EN (Jun 2022) Important Environmental Concerns Important Responsible Refrigerant Practices Copyright Trademarks Ordering Numbers Storage/Operating Specifications Agency Compliance Dimensions/Mounting/Removing the Controller Wiring Requirements Transformer Recommendations Wiring AC Power Startup and Power Check Input/Output Wiring Tug Test for Terminal Connectors BACnet MS/TP Link Wiring BACnet IP Wiring Factory Defaults
  • Media type icon

    RT-PRC104A-EN_04292022

    Document Title:Get Ready for the Future - Overview of Upcoming Regulatory Changes
    Publication Type:Sales Brochure
    Publication Date:2022-04-29
    Rights Reserved.All trademarks referenced in this document are the trademarks of their respective owners. RT-PRC104A-EN 04/29/2022 New Commercial Minimum Efficiency StandardsThe new 2023 system cooling efficiency minimums are increasing on commercial units above 65K BTU by approximately 15%. The