    BAS-PTS013B-EN_04072026

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for Sintesis™ Air-Cooled Chiller Model RTAF
    Publication Type:Points List
    Publication Date:2026-04-07
    Alarm BI-11086 34087 Comm Loss: Fan Board 2 Relay 2 - Ckt20 = Normal 1 = In Alarm BI-11087 34088 Comm Loss: Fan Board 2 Relay 3 - Ckt10 = Normal 1 = In Alarm BAS-PTS007B-EN Binary Input Diagnostics 18 Symbio™ 800 Integration Points List BACnet®/Modbus™Sintesis™ Model RTAF Date: 04/07/2026 Reference
  • Media type icon

    2309-7552J_02232021

    Document Title:RTHD Schematic, Wye-Delta Starter, Page 1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-02-23
    PUEDEPROVOCAR DAÑOS EN EL EQUIPO. AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONTPAS CONÇUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. UN MANQUEMENT À LA PROCÉDURECI-DESSUS PEUT ENTRAÎNER DES DOMMAGES À L'ÉQUIPEMENT. NOTICEUSE COPPER CONDUCTORS ONLY! UNIT TERMINALS ARE
  • Media type icon

    1213-4334E_04102023

    Document Title:SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-04-10
    CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES
  • Media type icon

    1213-4794B_06132024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, SINGLE CONDENSER FAN, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    OCASIONAR DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
  • Media type icon

    SYS-SLB036-EN_02072025

    Document Title:Thermal Battery Storage-Source Heat Pump Systems - Harnessing the fexibility of electrified ice heating
    Publication Type:Sales Brochure
    Publication Date:2025-02-07
    water temperature for a more resilient system solution. Make electri�ed heating possible in Heat your building even when temperatures drop below 0°F (-18°C). 8 7 6B 6A 5C 5B 5A 4C 4B 4A 3C 3B 3A 2B 2A 1B 1A 0B 0A “Cold”Climates Source: ANSI/ASHRAE Standard 169-2021. Climate Data for Building Design
  • Media type icon

    1213-5032B_07102024

    Document Title:PRECEDENT UNIT SCHEMATIC; SHEET 1 POWER, SINGLE COMPRESSOR, SINGLE VS CONDENSER FAN, STD SCCR, A CAB
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-07-10
    DAÑO AL EQUIPO. N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! LES BORNES DE L'UNITÉ NE SONT PAS CONÇUESPOUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS. L'UTILISATION DE TOUT AUTRE CONDUCTEUR PEUTENDOMMAGER L'ÉQUIPEMENT. PRECAUCIÓNATTENTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
  • Media type icon

    12134935_B_02282024

    Document Title:IPAK 2 COMPONENT LAYOUT 90-150T UNIT DEVICE LOCATIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-28
    SENSOR - SUCTION PRESSURE CIRCUIT #2 8672BT1 OUTDOOR AIR TEMPERATURE 8672E1 CRANKCASE HEATER #1 - COMPRESSOR 1A 8922E2 CRANKCASE HEATER #1 - COMPRESSOR 1B 8922E3 CRANKCASE HEATER - COMPRESSOR 1C 8922E4 CRANKCASE HEATER - COMPRESSOR 2A 8642E5 CRANKCASE HEATER - COMPRESSOR 2B 8642E8 CRANKCASE HEATER
  • Media type icon

    2311-6020D_11152024

    Document Title:Symbio 800 Control, W Frame, CGAM Refresh
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-15
    DIAGRAMSCHEMATIC WIRING POWER DISTRIBUTION AND COMPRESSOR POWER, CIRCUIT 1W FRAME CGAM REFRESH JESSICA YUAN 18 MAR 2022 6Q 1 1F5 1F6 17A 3M1 M COMPRESSOR 1ACIRCUIT 1 COMPRESSOR 1BCIRCUIT 1 COMPRESSOR 1CCIRCUIT 1 T1 T2 T3 10A 10A 11A 11A 12A 12A 7A 8A 9A 1A,C 1X1 2A,C 1B 2B 3B 1F1 1F2 1C 2C 1K1-AUX 21 22
  • Media type icon

    ODR-SVN003D-EN_04182026

    theindoor unit and linesets to 150 PSIG using dry nitrogen. Figure 20. Pressure check 2. Check for leaks by using a soapy solution at eachbrazed location.Note: Remove nitrogen pressure and repair any leaks before continuing. Figure 21. Check for leaks 18 ODR-SVN003D-EN Table 14. Nitrogen purge times Flow
  • Media type icon

    12134356_B_07192022

    Document Title:IPAK1 POWER SCHEMATIC 90-130T AIRFLOW, WITHOUT BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-07-19
    SUPPLY FAN VFD #1 256TB2 SUPPLY FAN VFD #2 326TB6 RELIEF FAN VFD 39 19A (O)18A (BR) 1A 1M 2A 3A 2M 3M 1A 2A 1M 2M 3A 3M 3L (Y) 3L 2L (O) 2L 1L (BR) 1L BR BR BR BRBR BRO O O OO OY Y Y YY Y 6XP89 6XP90 6XP114 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34