Search Results: TEMP-PRC013A-EN

Showing 331 - 340 of 7,116 results

Display results per page.
  • Media type icon

    BAS-SVX082E-EN_11152025

    Document Title:E50 Series Compact Power and Energy Meters BACnet (E50H2-T2) for use with split-core and solid-core CT's
    Publication Type:Installation
    Publication Date:2025-11-15
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. November 2025 BAS-SVX082E-EN Installation, Operation, and
  • Media type icon

    RT-PRC105E-EN_02292024

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Cooling and Electric Heat High Efficiency 6 to 25 Tons — 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2024-02-29
    in the performancesection. General Data RT-PRC105E-EN 21 Gross Cooling CapacitiesTable 5. Gross cooling capacities — 6 tons CFMEnt DB(°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F)61 67 73 61 67 73 61 67 73 MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh SHC MBh
  • Media type icon

    18-HE137D1-1A-EN_11272024

    Document Title:Installer’s Guide- Down Discharge Economizer and Rain Hood, BAYECON105A, BAYECON106A, BAYRLAY004B
    Publication Type:Installation
    Publication Date:2024-11-29
    Installer’s Guide November 2024 18-HE137D1-1A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilat-ing, and air-conditioning equipment can be hazardous and requires specific knowledge and training
  • Media type icon

    DLR-SVN006B-EN_02252026

    Document Title:Side Discharge Heat Pump
    Publication Type:Installation
    Publication Date:2026-02-25
    . Troubleshooting DLR-SVN006B-EN 35 Pressure CurvesCooling performance can be checked when theoutdoor temp is above 65° F.To check cooling performance, select the proper indoorcfm, allow pressures to stabilize. Measure indoor wet bulbtemperature, outdoor temperature, discharge and suctionpressures.On the
  • Media type icon

    PKGR-PSD007B-EN_09102025

    71 73 Performance Heating(c) Input BTUH-1st Stage 72000 72000 92000 92000 Input BTUH-2nd Stage 90000 90000 115000 115000 AFUE 81 81 81 81 Temp rise-Min/Max (°F) 30 / 60 30 / 60 40 /70 30 / 60 Product Specifications PKGR-PSD007B-EN 7 Table 3. Models – 5YCZ5042A1090A, 5YCZ5048A1090A, 5YCZ5048A1115A
  • Media type icon

    23116740_C_09022025

    - CONDENSATE OVERFLOW COIL 511PB1 BLOCK - POWER 61S4 SWITCH - UNIT DISCONNECT 11S5 SWITCH - FAN STATUS CONTACTS 561S5 SWITCH - FAN STATUS COIL 111T1 TRANSFORMER - CONTROL POWER 131U1 MODULE - S400B CONTROLLER 391U2 MODULE - HEX I/O 312B1 MOTOR - COMPRESSOR 162DTL SWITCH - DISCHARGE LINE TEMP 62HPC1 SWITCH
  • Media type icon

    23116741_C_09022025

    OVERFLOW CONTACTS 371PB1 BLOCK - POWER 61S4 SWITCH - UNIT DISCONNECT 11S5 SWITCH - FAN STATUS COIL 121S5 SWITCH - FAN STATUS CONTACTS 561T1 TRANSFORMER - CONTROL POWER 131U1 MODULE - S400B CONTROLLER 401U2 MODULE - HEX I/O 312B1 MOTOR - COMPRESSOR 162DTL SWITCH - DISCHARGE LINE TEMP 62HPC1 SWITCH
  • Media type icon

    BAS-SVP060A-EN_10082022

    installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2022 BAS-SVP060A-EN Integration
  • Media type icon

    4619-4479B_10112022

    Document Title:Vertical Unit Ventilators
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-10-11
    VOLTAJE ALMACENADO. AutoCAD SHX Text DESCONECTE TODA LA ENERGÍA ELÉCTRICA, AutoCAD SHX Text FAILURE TO DO THE ABOVE COULD RESULT IN AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text N'UTILISER QUE DES CONDUCTEURS EN CUIVRE! AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT PAS
  • Media type icon

    BAS-PTS006A-EN_11152024

    Document Title:Symbio™ 700 Integration Points List LonTalk® for Odyssey™
    Publication Type:Points List
    Publication Date:2024-11-15
    Symbio™ 700 Integration Points ListLonTalk®Odyssey™ Date: 11/15/2024Reference Document: BAS-SVP086*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted by name and