Search Results: THER-IN-33C

Showing 3,231 - 3,240 of 3,327 results

Display results per page.
  • Media type icon

    4366-8511A_08082014

    Document Title:Precedent Wiring Diagram; Ultra High Efficiency eFlex Precedent Power Diagram - YZC048E4, YZC060E4, Variable Speed Compressor
    Publication Type:Wiring Diagram or Manual
    Publication Date:2014-08-08
    1OAH/OAE 1 1EXF 11 OUT 2-10VDC IN 2-10VDC 6P91. 152A(RD)2. 153A(PR) 6P101. 154A(PR)2. 155A(BU) 6P121. 156A(RD)2. 157A(PR) 6P131. 146A(PR)2. 147A(BU) TO POWEREXHAUST 147A(BU) W28(BU) +- --++ RAS 155A(BU) 154A(PR)+- OHS 157A(PR)156A(RD) RHS 153A(PR)152A(RD) +- 1 ZONE SENSOR 12345678910 2345678910 7
  • Media type icon

    1213-5016B_09112024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, DUAL CONDENSER FAN, EFLEX, 230V/460V, STD SCCR (1phase, 1C)
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-11
    WIRED IN THE 203V CONFIGURATION. FOR 208V OPERATION MOVE WIRE TO THE 208V TAP ON ALL 3 CONTROL POWER TRANSFORMERS. WIRES 128A, 129A, 130A PRESENT ON UNITS WITH OPTIONAL ELECTRIC HEAT.WIRES 131A, 132A, 133A PRESENT ON UNITS WITH OPTIONALDISCONNECT/CIRCUIT BREAKER. 2. SOLID LINES INDICATE WIRING PROVIDED
  • Media type icon

    231158510001_08152021

    Document Title:DELUXE CONTROLS HEAT PUMP w/WATER SIED ECONOMIZER AND ECM MOTOR, THREE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-15
    OFF ANTI-SHORT CYCLEFLASHON OFF NORMAL / COMP ONON FLASH ON BURNOUT CONDITIONOFFONON ONON ON ON FLASHFLASH ON FLASHON ON ONFLASH ONFLASH ON OFF SOFT LOCKOUT LP MANUAL LOCKOUT LPSOFT LOCKOUT HP MANUAL LOCKOUT HPMANUAL LOCKOUT CONDENSATE LEVELCOMPRESSOR DISABLE 123 4. ALL FIELD WIRING MUST BE IN
  • Media type icon

    5071-2742A_01302021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Generic with Optional HGBP or FRCL
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-01-30
    POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. PODR虯 OCASIONAR LA MUERTE O SERIAS ADVERTENCIA DESCONECTE TODA LA ENERG虯 EL蒀TRICA, iVOLTAJE PELIGROSO! HAYAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES
  • Media type icon

    1213-4334B_02022022

    Document Title:Precedent™ SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, DUAL CONDENSER FAN, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-02-02
    THAT ARE DUAL RATED FOR 208/230V ARE SHIPPED WITHTRANSFORMER WIRED IN THE 230V CONFIGURATION. FOR 208V OPERATIONMOVE WIRE TO THE 208V TAP ON ALL 3 CONTROL POWER TRANSFORMERS. INSET A 4 5 5 444 SHEET 4SHEET 3 SHEET 4 SHEET 3 SHEET 4 SHEET 3 SHEET 4 5 2 2 3 3 3 4 4 4 5 5 5 6 6 6 WIRE COLOR ABBREVIATION
  • Media type icon

    1213-4335B_03302022

    Document Title:Precedent™ SCHEMATIC; SHEET 1, POWER, DUAL COMPRESSOR, SINGLE CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-03-30
    POINTING UPWARD BELOW THE LINE NUMBER INDICATES A TIMED CONTACT WHICH BEGINS TIMING WHEN ENERGIZEDTNS3 PRESENT ON UNITS WITH OPITONAL HOT GAS RE HEAT ONLY. SEE INSETA FOR 3 TRANSFORMER WIRING CONFIGURATIONUNITS THAT ARE DUAL RATED FOR 208/230V ARE SHIPPED WITHTRANSFORMER WIRED IN THE 230V
  • Media type icon

    1213-4719_A_02142023

    Document Title:Schematic; Sheet 1, Power, Dual Compressor, Single Condenser Fan, Std SCCR, with Supply VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-14
    WIRING CONFIGURATIONUNITS THAT ARE DUAL RATED FOR 208/230V ARE SHIPPED WITHTRANSFORMER WIRED IN THE 230V CONFIGURATION. FOR 208V OPERATIONMOVE WIRE TO THE 208V TAP ON ALL 3 CONTROL POWER TRANSFORMERS. INSET A 1 2 1 2 2 2 1 2 2 3 3 3 4 4 4 5 5 5 WIRE COLOR ABBREVIATION CODESCODE COLOR COLORCODE BK BLACK PINKPKBL BLUE REDRBR BROWN TURQUOISETQG GREEN PURPLEV,(PR) GY GREY WHITEWO ORANGE YELLOWY RELEASED 14/Feb/2023 14:57:27 GMT Sheet 1
  • Media type icon

    23116498B_03212025

    Document Title:DLX HP BLRLS EH, LDS 3PH GE/EX
    Publication Type:Wiring Diagram or Manual
    Publication Date:2025-03-21
    J4LB-3 J4LC-4 J4LB-4 1MR 1S5 1S5 123456 123456 1 1 2 2 34 12341 23 12345 123456 123 4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), STATE AND LOCAL REQUIREMENTS. ALL LOW VOLTAGE FIELD CONNECTIONS ARE CLASS 2. VERIFY TEST JUMPER IS NOT CONNECTED/REMOVED TO PREVENT
  • Media type icon

    2311-5509E_11022021

    Document Title:Ascend Model ACR, 150 to 300 tons, Schematic Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-11-02
    COULD RESULT IN DEATH OR SERIOUS INJURY. ! AVERTISSEMENTTENSION DANGEREUSE! COUPER TOUTES LES TENSIONS ET OUVRIRLES SECTIONNEURS À DISTANCE, PUIS SUIVRELES PROCÉDURES DE VERROUILLAGE ET DES ÉTIQUETTES AVANT TOUTE INTERVENTION.VÉRIFIER QUE TOUS LES CONDENSATEURS DES MOTEURS SONT DÉCHARGÉS. DANS LE
  • Media type icon

    1213-0801B_11082016

    Document Title:Small Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-11-08
    SIZEL1 L2 L3 WHEN OPTIONAL ELECTRIC HEAT IS INSTALLED, LINE VOLTAGE ISCONNECTED TO HTB2 IN THE ELECTRIC HEAT CONTROL PANEL. 28C(R) 29B(BL) 3P(BK) FOR 380V/415V WIRING CONNECTIONS, SEE INSET D. INSET "D" - OPTIONAL 400V TRANSFORMER 100A(R)100B(R) 3P(BK) ,3P(BK) ,3P(BK) ,3P(BK) 1K(R) 2K(BL) 2K(BL)1K(R