Search Results: THER-IN-33C

Showing 3,221 - 3,230 of 3,327 results

Display results per page.
  • Media type icon

    231158500001_08152021

    Document Title:DELUXE CONTROLS HEAT PUMP w/HOT GAS REHEAT AND ECM MOTOR, THREE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-15
    LOCKOUT CONDENSATE LEVELCOMPRESSOR DISABLE 123 HUMIDSTAT 6 4 5 2 4 1 3 1 3 4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), STATE AND LOCAL REQUIREMENTS. ALL LOW VOLTAGE FIELD CONNECTIONS ARE CLASS 2. VERIFY TEST JUMPER IS NOT CONNECTED/REMOVED TO PREVENT CONTROL
  • Media type icon

    23116088_C_03272023

    Document Title:WSHP SCHEMATIC DIAGRAM DXV/DXH DELUXE CONTROL - HP W/ HGR ECM - SINGLE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    HUMIDSTAT 6 4 5 2 4 1 3 1 3 5 6 1 3 4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), STATE AND LOCAL REQUIREMENTS. ALL LOW VOLTAGE FIELD CONNECTIONS ARE CLASS 2. VERIFY TEST JUMPER IS NOT CONNECTED/REMOVED TO PREVENT CONTROL TIMING ERRORS. ISOLATED GENERAL ALARM CONTACTS
  • Media type icon

    12134548_C_04102023

    Document Title:PRECEDENT UNIT SCHEMATIC; SHEET 1 POWER, DUAL COMPRESSOR, WSHP STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-04-10
    ARE SHIPPED WITHTRANSFORMER WIRED IN THE 230V CONFIGURATION. FOR 208V OPERATIONMOVE WIRE TO THE 208V TAP ON ALL 3 CONTROL POWER TRANSFORMERS. INSET A 4 5 5 444 SHEET 4SHEET 3 SHEET 4 SHEET 3 SHEET 4 SHEET 3 SHEET 4 5 2 2 3 3 3 4 4 4 WIRE COLOR ABBREVIATION CODESCODE COLOR COLORCODE BK BLACK PINKPKBL BLUE REDRBR BROWN TURQUOISETQG GREEN PURPLEV,(PR) GY GREY WHITEWO ORANGE YELLOWY RELEASED 10/Apr/2023 17:04:35 GMT Sheet 1
  • Media type icon

    1213-5029B_10162024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, SINGLE VS CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-16
    PPF351 1 2 UNITS THAT ARE DUAL RATED FOR 208/230V ARE SHIPPED WITHTRANSFORMER WIRED IN THE 230V CONFIGURATION. FOR 208V OPERATIONMOVE WIRE TO THE 208V TAP ON ALL CONTROL POWER TRANSFORMERS. L1 L2 T2 T1 4 5 4 4 WIRE COLOR ABBREVIATION CODESCODE COLOR COLORCODE BK BLACK PINKPKBL BLUE REDRBR BROWN
  • Media type icon

    23116505B_03212025

    Document Title:DLX HP BLRLS EH, FS 1PH GE/EX
    Publication Type:Wiring Diagram or Manual
    Publication Date:2025-03-21
    LOCKOUT HPMANUAL LOCKOUT CONDENSATE LEVELCOMPRESSOR DISABLE COMNOR1R2 J1 ON/OFF GNDPWM 1TB2-1 1TB2-2 J4B- 4J4 B-3 BA 46 31 1K1 1S5 1234 123456 12341 23 12345 123 4. ALL FIELD WIRING MUST BE IN ACCORDANCE WITH THE NATIONAL ELECTRIC CODE (NEC), STATE AND LOCAL REQUIREMENTS. ALL LOW VOLTAGE FIELD
  • Media type icon

    2311-5509E_11022021

    Document Title:Ascend Model ACR, 150 to 300 tons, Schematic Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-11-02
    COULD RESULT IN DEATH OR SERIOUS INJURY. ! AVERTISSEMENTTENSION DANGEREUSE! COUPER TOUTES LES TENSIONS ET OUVRIRLES SECTIONNEURS À DISTANCE, PUIS SUIVRELES PROCÉDURES DE VERROUILLAGE ET DES ÉTIQUETTES AVANT TOUTE INTERVENTION.VÉRIFIER QUE TOUS LES CONDENSATEURS DES MOTEURS SONT DÉCHARGÉS. DANS LE
  • Media type icon

    2311-6020D_11152024

    Document Title:Symbio 800 Control, W Frame, CGAM Refresh
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-15
    . AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE! L'UTILISATION DE MATAUTRES QUE LE CUIVRE,PEUT ENDOMMAGER L'CELUI-CI N'AYANT PAS HOMOLOGUTYPES DE CONDUCTEURS. NOTICEUSE COPPER CONDUCTORS ONLY! FAILURE TO USE COPPER CONDUCTORSCOULD RESULT IN EQUIPMENT DAMAGEAS THE EQUIPMENT WAS NOT DESIGNEDOR QUALIFIED TO ACCEPT
  • Media type icon

    2309-4623T_05042022

    Document Title:RTAC Schematic, 4 Compressor Units, X-Line Starter
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-05-04
    SIZE. ONLY LUGS ARE PROVIDED FOR FIELD WIRING IN THE SINGLE SOURCE PANEL. WIRING FOR 460V UNIT SHOWN. SEE INSET "A" FOR CONTROL POWER TRANSFORMER WIRING FOR OTHER VOLTAGES. SINGLE SOURCE POWER OPTIONS ARE AVAILABLE WHEN VOLT = 400, 460 OR 575. DUAL SOURCE POWER IS PROVIDED WHEN VOLT = 200, 230 OR 380
  • Media type icon

    231158510001_08152021

    Document Title:DELUXE CONTROLS HEAT PUMP w/WATER SIED ECONOMIZER AND ECM MOTOR, THREE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-15
    OFF ANTI-SHORT CYCLEFLASHON OFF NORMAL / COMP ONON FLASH ON BURNOUT CONDITIONOFFONON ONON ON ON FLASHFLASH ON FLASHON ON ONFLASH ONFLASH ON OFF SOFT LOCKOUT LP MANUAL LOCKOUT LPSOFT LOCKOUT HP MANUAL LOCKOUT HPMANUAL LOCKOUT CONDENSATE LEVELCOMPRESSOR DISABLE 123 4. ALL FIELD WIRING MUST BE IN
  • Media type icon

    5071-2742A_01302021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Generic with Optional HGBP or FRCL
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-01-30
    POWER INCLUDING REMOTE DISCONNECTS AND FOLLOW LOCK OUT FAILURE TO DO THE ABOVE BEFORE SERVICING COULD RESULT IN DEATH OR SERIOUS INJURY. PODR虯 OCASIONAR LA MUERTE O SERIAS ADVERTENCIA DESCONECTE TODA LA ENERG虯 EL蒀TRICA, iVOLTAJE PELIGROSO! HAYAN DESCARGADO EL VOLTAJE ALMACENADO. PARA LAS UNIDADES