Search Results: TEMP-SVX005C-EN

Showing 311 - 320 of 7,119 results

Display results per page.
  • Media type icon

    1213-1532B_11082016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-11-08
    CONTROL BOX 11 HTB2 TERMINAL BLOCK - ELECTRIC HEAT 4,7 HTRA HEATER 15 HTRB HEATER 19 TCO1 TEMP CUTOUT 17 TCO2 TEMP CUTOUT 18 TRANE FILE NUMBER: DRAWING NUMBER: SHEET: REV 12131529 12131532 1OF1 BTHIS DRAWING IS PROPRIETARY AND SHALL NOT BE COPIED OR ITS CONTENTS DISCLOSED TO OUTSIDE PARTIES WITHOUT THE
  • Media type icon

    BAS-PTS004A-EN_09182024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for IntelliPak™
    Publication Type:Points List
    Publication Date:2024-09-18
    Symbio™ 800 Integration Points ListLonTalk®IntelliPak™ Date: 09/18/2024Firmware Release: 62000663-4-10-0002Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable
  • Media type icon

    RT-SVX45F-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology, Electric/Electric 3 to 10 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    nuts to the two (2) field supplied wires that were connected to terminals 1 and 2 on J6. RT-SVX45F-EN 49 Troubleshooting Table 8. Fault detection and diagnostic codes Primary Fault Codes Information Code Failures Mixed Air Temp Sensor Fail Outdoor Temp Sensor Fail Economizer Actuator Fault RTEM Comm
  • Media type icon

    BAS-PTS002A-EN_11082024

    Symbio™ 700 Integration Points ListLonTalk®Precedent® and Axiom™ Rooftop WSHP Date:11/08/2024Firmware Release: V7.00.0011 Reference Document: BAS-SVP086*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by
  • Media type icon

    WSHP-SVX024B-EN_12012025

    Document Title:Water Source Heat Pump Axiom™ Variable Speed – VSH/VSV
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-01
    anti-freeze solution having a freezing point20°F lower than the minimum expected enteringtemperature. 50 WSHP-SVX024B-EN Table 34. Operating pressures in cooling/heating - VSH Model No. Cooling Heating EnteringWater Temp (°F) Water Flow(GPM) SuctionPressure,PSIG DischargePressure(PSIG) Water TempRise
  • Media type icon

    OAU-SVX01L-EN_06262023

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Discharge Air Temp. Reset for Single Zone VAV 85 Supply Fan Tracking for Exhaust Fan (Field En-abled) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Hot Water Reheat . . . . . . . . . . . . . . . . . . . 85 Expanded Fallback
  • Media type icon

    BAS-PTS003C-EN_12172025

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for IntelliPak™
    Publication Type:Points List
    Publication Date:2025-12-17
    Units Write °F 40 to 110 0 Holding 40015 AV-10149Daytime Warmup Setpoint BAS Defines the space temp below which daytime warmup will be enabled Heat Present and Discharge Temperature Control Write °F 50 to 87 0 Holding 40017 BAS-PTS003C-EN Analog Values 34 Symbio™ 800 Integration Points List BACnet®
  • Media type icon

    RT-SVX37C-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™- Electric/Electric 5 – 10 Tons – 50 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    Discharge AirSensing Tube14 8 Novar Return Air Sensor (NOVAR 2024)15,29 9 Novar Zone Temp Sensor (NOVAR 3051)18,29 A Condensate Drain Pan OverflowSwitch B Clogged Filter Switch14 andCondensate Drain Pan OverflowSwitch RT-SVX37C-EN 5 Model Number Descriptions C Fan Failure Switch14 and CondensateDrain Pan
  • Media type icon

    ACC-SVN311A-EN_09152024

    0-100% Low Leak Economizer -Downflow/HorizontalFoundation™ Packaged Rooftop Units15 to 25 Tons Installation Instructions September 2024 ACC-SVN311A-EN Model Numbers: Used With: BAYECON358* E/GDK180-300 DownflowBAYECON359* E/GDK180-300 Horizontal Flow SAFETY WARNINGOnly qualified personnel should
  • Media type icon

    UH-SVN001B-EN_04242020

    Document Title:Horizontal/Vertical Combustion Air Inlet Kit Category III Venting for Separated Combustion Tubular Gas Fired Unit Heaters Five-Inch Kit for 100,000 to 250,000 Btu/h Units Six-Inch Kit for 300,000 to 400,000 Btu/h Units
    Publication Type:Installation
    Publication Date:2020-04-24
    Heaters - Five-Inch Kit for 100,000 to 250,000 Btu/h Units; Six-Inch Kit for 300,000 to 400,000 Btu/h Units • (1) Part No. 11H03R03612-002: Tube of High Temp Silicone Sealant • (3) Part No. 11H03R09571-006: Gasket, O-ring, 6-in. Figure 4. Kit contents (drawing D8980B) 1 4 3 2 1 4 3 2 6 UH-SVN001B-EN