Search Results: 18-HD83D1-5B-EN

Showing 2,131 - 2,140 of 7,117 results

Display results per page.
  • Media type icon

    IB-SVX147D-EN_08072020

    Document Title:Ice Bank Energy Storage Operation and Maintenance Manual
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-08-07
    Ice Bank® Energy Storage Operation and Maintenance Manual August 2020 IB-SVX147D-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires
  • Media type icon

    EDU-SLB078-EN_07112025

    Document Title:Higher Education Investment Initiatives- Financing, Funding, and Procurement Strategies
    Publication Type:Sales Brochure
    Publication Date:2025-07-11
    Exempt Lease Purchase (TELP) Traditional Financing & Third-Party Ownership Models Learn More https://www.trane.com/commercial/north-america/us/en/energy-services/financing-implementation/performance-contracts.html https://www.trane.com/commercial/north-america/us/en/energy-services/financing
  • Media type icon

    EDU-SLB045-EN_07112025

    Document Title:Energy Strategies for Campus Challenges
    Publication Type:Sales Brochure
    Publication Date:2025-07-11
    your financing and contracting options to determine the best way to achieve your institutional goals. https://www.trane.com/commercial/north-america/us/en/energy-services/financing-implementation.html https://www.trane.com/commercial/north-america/us/en/energy-services/financing-implementation.html
  • Media type icon

    1213-4305B_03302022

    BOX 10HTB4 TERM BLOCK-ELECTRIC HEAT 5HTR 1A HEATER-ELECTRIC HEAT 12HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS HAVE DISCHARGEDSTORED VOLTAGE. UNITS WITHVARIABLE
  • Media type icon

    SRV-SLB278-EN_04042024

    Document Title:Rental Services for Data Centers - Temporary Cooling Solutions for Mission-Critical Needs
    Publication Type:Sales Brochure
    Publication Date:2024-04-04
    , including: • Equipment lead times limiting speed to market • Planned maintenance, expansion or emergencies threatening uptime • Additional cooling power required to maintain peak operation and ensure redundancy https://www.trane.com/commercial/north-america/us/en/services/rentals.html https
  • Media type icon

    KIT06500_08012006

    Document Title:KIT06500 KIT; REFRIGERANT CYLINDER
    Publication Type:Installation
    Publication Date:2006-08-01
    KIT06500 KIT; REFRIGERANT CYLINDER COMPONENT Description Item Proc In Date Out Date Qty UOMX39001480010 LABEL; REFRIGERANT SAMPLE STK RAW 12/10/1999 1 EACHX18100818010 BOX; RETURN - 4"x 4"x 18" STK RAW 12/10/1999 1 EACHX45130275010 TAPE; .50 WIDE TEFLON X 1296" STK RAW 12/21/1999 4 InchX24040392010
  • Media type icon

    KIT08357_08012006

    Document Title:KIT08357 KIT; E8 VALVE KIT, TOP OVERHAUL, INCLUDES GASKETS
    Publication Type:Installation
    Publication Date:2006-08-01
    8GKT02721 GASKET-DISTRIBUTOR PLATE (NON-ASBESTOS) R-123 COMPATIBLE LAKJK 1RNG00093 RING; RETAINING, .75 ID, SELF-LOCKING .017 THK, EXTERNAL, SPRING STL 1VAL01091 VALVE; RING,SUCTION 8GKT02767 GASKET;SUCTION COVER (NON-ASBESTOS) R-123 COMPATIBLE LAKJK 1NUT00970 NUT; LOCK, HEX, .63-18 (1 CTN = 10 PCS
  • Media type icon

    CGWA-W-20_02011981

    Document Title:Liquid Chiller - Reciprocating Water-Cooled Cold Generator - Models CGWA0800RB/RC, CGWA100RB/RC, CGWA120RB/RC - B, C Design, Dual Model R Compressors
    Publication Type:Wiring Diagram or Manual
    Publication Date:1981-02-01
    C:\Trane#16\0004.tif image 1 of 36 image 2 of 36 image 3 of 36 image 4 of 36 image 5 of 36 image 6 of 36 image 7 of 36 image 8 of 36 image 9 of 36 image 10 of 36 image 11 of 36 image 12 of 36 image 13 of 36 image 14 of 36 image 15 of 36 image 16 of 36 image 17 of 36 image 18 of 36 image 19 of 36
  • Media type icon

    1213-2576_10292018

    Document Title:INTELLIPAK - POWER SCHEMATIC, 20T-30T - REFRIGERATION WITH COMPRESSOR VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2018-10-29
    - - - - - - - - - REFRIGERATION SYSTEMS WITH VARIABLE SPEED COMPRESSOR- - -- - - - - -- - - - - - - - - 12132576 CL. D'ALBANI K. EDWARDS 10/23/18 REFRIGERATION SYSTEMSWITH COMPRESSOR VFD - - -- - - - - - 04/11/18 R. ROBINSON D. CONDIE LEGENDDEVICE DESIGNATION DESCRIPTION LINENUMBER 1F10 FUSEBLOCK - COND FAN 921F14 FUSEBLOCK
  • Media type icon

    MC-SLB037-EN_06162020

    Document Title:High efficiency inverter systems - 4MXW/4MYW 9-24 MBH-up to 15 SEER-60Hz
    Publication Type:Sales Brochure
    Publication Date:2020-06-16
    High Efficiency Inverter Systems4MXW/4MYW 9-24 MBH- up to 15 SEER-60Hz Trane Ductless Systems— Reliable and efficient solutions 8 10 13 16 18 22SEER Ener gy S avin gs (% ) 64%56%50%38%20% 0 Time(t) Trane Others SetpointRoom ( )°C Time(t) Trane Others SetpointRoom ( )°C 1°C0.5°C Time(t) Trane Others