    3518-7218A_03152020

    Document Title:Forceflo Thermostat
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    \\shahns07\Air_Side_Projects\14_PCC_VAVE\115_Low cost ECM and T-Stat\03_Design\Drawing\Pending\Schematic for SC900V\CAD\3518721 RELEASED 18/Dec/2019 12:22:54 GMT
  • Media type icon

    3518-7217A_03152020

    \\shahns07\Air_Side_Projects\14_PCC_VAVE\115_Low cost ECM and T-Stat\03_Design\Drawing\Pending\Schematic for SC900V\CAD\3518721 RELEASED 18/Dec/2019 12:22:55 GMT
  • Media type icon

    APP-PRC006B-EN_02202024

    14ºF ∆T condenser water ASHRAE GreenGuide10 • 12-20°F ΔT chilled water• 12-18°F ΔT condenser water CoolTools™ Chilled Water Plant Design and Specification Guide, 200011 • 15-18°F ΔT chilled water Kelly and Chan, Optimizing Chilled Water Plants, HPAC Engineering, 199912 • 18°F ΔT chilled water• 14°F
  • Media type icon

    ACC-SVN82G-EN_04212020

    Document Title:Discharge Air Sensing Kit
    Publication Type:Installation
    Publication Date:2020-04-21
    periods for discharge of capacitors. Verify with an appropriate voltmeter that all capacitors have discharged. For additional information regarding the safe discharge of capacitors, see PROD-SVB06A-EN Figure 1. C cabinet exploded view 1. Disconnect all power to the unit.2. Remove the supply fan access
  • Media type icon

    2311-4621A_03152020

    Document Title:HUV Trane Furnished Controls
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    : ANGLES =  HOLE DIA = + - CONFORMS TO ASME Y14.5M - 1994 SHEET OF REV  FINISH TRANE 2311-4621 A 1 1 SCHEMATIC; HUV TRANE FURNISHED CONTROLS 277 VOLT, 1 PH, 2-WIRE ELECTRIC HEAT (6 EL) UNIT SIZE 1000-2000 SPAINHOUR 7-APR-2017 .06 .03 .015 .005 .005 1 RELEASED 11/Apr/2017 18:35:01 GMT
  • Media type icon

    2311-4618A_03152020

    Document Title:HUV Trane Furnished Controls
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-03-15
    : ANGLES =  HOLE DIA = + - CONFORMS TO ASME Y14.5M - 1994 SHEET OF REV  FINISH TRANE 2311-4618 A 1 1 SCHEMATIC; HUV TRANE FURNISHED CONTROLS 277 VOLT, 1 PH, 2-WIRE ELECTRIC HEAT (4 EL) UNIT SIZE 1250-2000 SPAINHOUR 7-APR-2017 .06 .03 .015 .005 .005 1 RELEASED 11/Apr/2017 18:34:59 GMT
  • Media type icon

    1213-4304B_03302022

    LADESCARGA DEL CONDENSADOR. EL NO REALIZAR LO ANTERIORMENTEINDICADO, PODRÍA OCASIONAR LA MUERTEO SERIAS LESIONES PERSONALES. (Y)(O) (BR) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58
  • Media type icon

    1213-4306C_08162022

    BOX 10HTB4 TERM BLOCK-ELECTRIC HEAT 5HTR 1A HEATER-ELECTRIC HEAT 12HTR 1B HEATER-ELECTRIC HEAT 15HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS HAVE
  • Media type icon

    1213-4311C_08162022

    BOX 10HTB4 TERM BLOCK-ELECTRIC HEAT 5HTR 1A HEATER-ELECTRIC HEAT 12HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS HAVE DISCHARGEDSTORED VOLTAGE. UNITS WITHVARIABLE
  • Media type icon

    PART-SVN138B-EN_05152020

    Document Title:Location of Parts Compressor Motor Change Out Kit: KIT16312, Model Number: PCV / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-15
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Number:PCV May 2020 PART-SVN138B-EN