Search Results: TEMP-PRC013A-EN

Showing 201 - 210 of 7,172 results

Display results per page.
  • Media type icon

    UV-PRC006D-EN_06192026

    Document Title:Vertical Classroom Unit Ventilator
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-06-19
    34 UV-PRC006D-EN Table 9. VUV 075, cooling coil E, 3-row/16 fpi (continued) EnteringWet BulbTemp (°F) EnteringDry BulbTemp (°F) EnteringWater Temp (°F) Flow Rate (gpm) 2 4 6 10 TotalCapacity(MBh) SensibleCapacity(MBh) T (°F)Total Capacity(MBh) SensibleCapacity(MBh) T (°F)Total Capacity(MBh
  • Media type icon

    ODR-SVN006C-EN_06262026

    Document Title:Link Variable Speed Heat Pumps and Air Conditioners
    Publication Type:Installation
    Publication Date:2026-06-26
    184 187 190 194 197 200 203 65 200 203 206 210 213 217 220 70 217 220 223 227 230 234 238 75 234 238 241 245 249 252 256 80 252 256 260 264 268 272 276 85 272 276 280 284 288 292 297 Unit Location Considerations ODR-SVN006C-EN 11 Table 11. Refrigerant chart (continued) Liquid Temp (°°F) Design
  • Media type icon

    SS-PRC052C-EN_03142026

    Document Title:Split System Air Conditioners Odyssey™ with Symbio™ Controls R–410A Dry Charge, Heat Pump Condenser 6, 7.5, 10, 15 and 20 Tons, 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-03-14
    (F) Capacity Curve - Condensing Unit Only 65F75F85F95F105F115F125F COM PRES SOR HIG H S UCT ION LIM IT ID C OIL FRO ST L IMIT Performance Data 36 SS-PRC052C-EN Table 20. Gross cooling capacities (MBH) 6 tons TWA0724*D condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30
  • Media type icon

    ODR-SVN004C-EN_06262026

    Document Title:Link Variable Speed Heat Pumps and Air Conditioners
    Publication Type:Installation
    Publication Date:2026-06-26
    Subcooling values, use Bubble Temp chart. If referencing Superheat, use Dew Point chart. Unit Location Considerations ODR-SVN004C-EN 11 Refrigerant PropertiesTable 11. Refrigerant properties Pgauge (psig) Superheat DewTable (°°F) Subcooling BubbleTable (°°F) 30 -12 -14 35 -7 -9 40 -2 -4 45 2 0 50 6 4 55 10
  • Media type icon

    PRGF-SVX001C-EN_04112026

    integrity. Check ambient conditions. Check heater operation. 30 PRGF-SVX001C-EN Table 6. Troubleshooting a purge system (continued) Diagnostic or Problem Cause Solution Carbon Regeneration Temp LimitExceeded (latching diagnostic) The carbon tank temperatureexceeded 120% of the regenerationtemperature
  • Media type icon

    ACC-SVN303A-EN_09152024

    Document Title:0 to 100% Downflow Dry Bulb Economizer Foundation™ Packaged Cooling and Gas/Electric 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    Sensor Differential Dry Bulb OA Temp < RA Temp - Economizer Dry Bulb Enable Offset - Economizer Dry Bulb Disable Return Air Offset Outdoor Air Temperature Sensor Return Air Temperature Sensor Figure 24. Fresh air options module location Fresh Air Module Access 12 ACC-SVN303A-EN Notes ACC-SVN303A-EN
  • Media type icon

    RT-PRC125A-EN_09152024

    -PRC125A-EN 27 Table 10. Gross cooling capacities 25 tons — E/GDK300A3,4,W CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) 61 67 73 61 67 73 61 67 73MBh SHC MBh SHC
  • Media type icon

    RSP-PRC019-EN_07012008

    Document Title:Shell and Tube Evaporators and Condensers from ServiceFirst
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2008-07-01
    factor.c) 85°F entering water temperature.d) 160°F entering refrig temp, 105°F saturated condensing temperature. PerformanceData 10 RSP-PRC019-EN DimensionalData Dimensional Data – InchesServiceFirstItemNumber ACME A J KRH RH w/HT LH LH w/Ht Model Number (O.A.L.) B C D E F G H (O.D.F.) (O.D.F.) L M
  • Media type icon

    RT-PRC023AY-EN_12202022

    capacity3. SHC = Sensible heat capacity 40 RT-PRC023AY-EN Table 11. Gross cooling capacities 4 tons standard efficiency — three phase T/YSC048G3,4,W CFMEnt DB(°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    RT-PRC060N-EN_12032022

    airflow table notes.2. MBh = Total gross capacity3. SHC = Sensible heat capacity Performance Data RT-PRC060N-EN 21 Table 5. Gross cooling capacities 20 tons - E/GCC240A3,4,W CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F