Search Results: 18-CH83D1-1B-EN

Showing 1,801 - 1,810 of 7,142 results

Display results per page.
  • Media type icon

    22-1772-03_04012009

    Document Title:Trane Split System Heat Pump Product and Performace Data XR13 2TWR3018-060 - 1 1/2-5 Tons
    Publication Type:Product Data
    Publication Date:2009-04-01
    XR 132TWR3018-060 1½ – 5 Tons Split SystemHeat Pump Product& Performance Data PUB. NO. 22-1772-03 SSP-PRC0??-EN © 2009 Trane 2 22-1772-03 Features andBenefits • Climatuff® compressor • Efficiency up to 14.00 SEER and8.50 HSPF • All aluminum Spine Fin™ coil • DuraTuff™ base, fast complete drain
  • Media type icon

    5071-2802A_08162021

    Document Title:CenTraVac® Schematic HDWA to Symbio 800 Upgrade CDUB
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-08-16
    AutoCAD SHX Text OTHER TYPES OF CONDUCTORS. AutoCAD SHX Text UNIT TERMINALS ARE NOT DESIGNED TO ACCEPT AutoCAD SHX Text PEUT ENDOMMAGER L'蒕UIPEMENT. AutoCAD SHX Text EN CUIVRE! AutoCAD SHX Text TYPES DE CONDUCTEURS. AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT AutoCAD SHX Text L'UTILISATION DE TOUT
  • Media type icon

    KIT05356_08012006

    Document Title:KIT05356 KIT; <150 PSIG WATER PRESSURE TRANSDUCER
    Publication Type:Installation
    Publication Date:2006-08-01
    KIT05356 KIT; <150 PSIG WATER PRESSURE TRANSDUCER COMPONENT Description Item Proc In Date Out Date Qty UOMX13310404010 CLIP; RELAY HOLD DOWN STK RAW 11/25/1998 2 EACHX09090295010 STRAINER, .25 NPS, WIRE MESH STK RAW 11/25/1998 4 EACHX16041000010 NIPPLE; .25 NPS X .88 BLK .25-18 NPT STL SCH 40 STK
  • Media type icon

    BAS-SVP060A-EN_10082022

    ) CO2 Maximum Setpoint AV111 Space CO2 Low Limit PPM 200 to 2,000 ModulatingOutdoor AirDamper Units(Economizer) CO2 Minimum Setpoint Object and Diagnostic Data Points 18 BAS-SVP060A-EN Table 3. Analog values (continued)ObjectType Object Name Units of Measure Min /Max When the PointExists Description
  • Media type icon

    KIT02330_08012006

    Document Title:KIT02330 KIT; GASKET & O-RING, 3 & 4 CYL MODEL M, NONASBESTOS ASBESTOS
    Publication Type:Installation
    Publication Date:2006-08-01
    KIT02330 KIT; GASKET & O-RING, 3 & 4 CYL MODEL M, NON-ASBESTOS COMPONENT Description Item Proc In Date Out Date Qty UOMX23040439010 GASKET; .031 X 2.75 X 2.12, CHLOROPRENE (NON-ASBESTOS) W/ANTI-STICK COATING ONE STK RAW 10/18/1999 1 EACHX23100012000 GASKET;CHECK VALVE STK RAW 12/23/1992 2
  • Media type icon

    5071-0523D_06062021

    Document Title:CenTraVac® Schematic AdaptiView Panel Upgrade with Subpanel Customer Supplied Starters Wye-Delta
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-06-06
    L'UTILISATION DE TOUT AUTRE CONDUCTEUR AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT AutoCAD SHX Text PEUT ENDOMMAGER L'蒕UIPEMENT. AutoCAD SHX Text TYPES DE CONDUCTEURS. AutoCAD SHX Text EN CUIVRE! AutoCAD SHX Text SI NO LO HACE, PUEDE OCASIONAR AutoCAD SHX Text TILICE 贜ICAMENTE CONDUCTORES AutoCAD SHX
  • Media type icon

    2311-5360C_09292021

    SUPPLIED CONTROL CIRCUIT WIRING MUST BE COPPER CONDUCTORS ONLY AND HAVE A MINIMUMINSULATION RATING OF 300V. EXCEPT AS NOTED, ALL CUSTOMER WIRING CONNECTIONS ARE MADE TO CIRCUIT BOARDMOUNTED BOX LUGS WITH A WIRE RANGE OF 14 TO 18 AWG. 12 CONTACT RATINGS AND REQUIREMENTS:UNIT PROVIDED DRY CONTACTS FOR THE
  • Media type icon

    BAS-SVP061C-EN_01102026

    Document Title:Symbio™ 400–B/500 Programmable Controller For Water Source Heat Pump
    Publication Type:Integration Guide
    Publication Date:2026-01-10
    ) WatersideEconomizing Units If the entering water temperature is the configuredenable setpoint, then economizing is possible.Economizing is not disabled until the watertemperature is 5°F above the setpoint. Factory defaultis 50°F. 18 BAS-SVP061C-EN Table 3. Analog values (continued)ObjectType Object
  • Media type icon

    1213-4813A_02142024

    Document Title:SCHEMATIC/COMPONENT LOCATION - ELECTRIC HEAT - 6 & 12 & 18 & 23 KW 208/240V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-14
    19HTB1 TERM BLOCK-CONTROL BOX 10HTB4 TERM BLOCK- TBUE 7HTB4 TERM BLOCK-ELECTRIC HEAT 5HTR 1A HEATER-ELECTRIC HEAT 12HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS
  • Media type icon

    1213-4814A_02142024

    Document Title:SCHEMATIC/COMPONENT LOCATION - ELECTRIC HEAT - 6 & 12 & 18 & 23 KW 460V/575V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-14
    19HTB1 TERM BLOCK-CONTROL BOX 10HTB4 TERM BLOCK-ELECTRIC HEAT 5HTB4 TERM BLOCK- TBUE 7HTR 1A HEATER-ELECTRIC HEAT 12HTR 2A HEATER-ELECTRIC HEAT 18 WARNING DISCONNECT ALL ELECTRIC POWERINCLUDING REMOTE DISCONNECTSAND FOLLOW LOCK OUT AND TAGPROCEDURES BEFORE SERVICING.INSURE THAT ALL MOTORCAPACITORS