Search Results: TEMP-PRC012A-EN

Showing 181 - 190 of 7,122 results

Display results per page.
  • Media type icon

    ODR-SVX016B-EN_04172026

    Document Title:Condensing Units
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    . Stabilize the system by operating for a minimum of 20minutes whenever charge is removed or added beforeaccurate measurements can be made. ODR-SVX016B-EN 23 4. Measure the liquid line temperature and pressure at theoutdoor unit’s service valve.Measured Liquid Line Temp = __________ º FLiquid Gage
  • Media type icon

    SO-SVU001A-EN_10132023

    AFD Surge Capacity Increase 1 Tracer TU Status View: Motor Average Line Current Starter Average Phase Voltage Starter Load Power Factor Motor Winding #1 temp Motor Winding #2 temp Motor Winding #3 temp SO-SVU001A-EN 51 Start-Up Test Log Water-Cooled CenTraVac Chiller with CH530/CH531 Control and
  • Media type icon

    PKGP-PRC019D-EN_09302023

    Heating Performance High Temp Btuh Rating 136000 164000 224000 250000 System Power (kW) / COP 11.99 / 3.30 14.39 / 3.30 20.51 / 3.20 22.16 / 3.20 Low Temp Btuh Rating 63500 76000 119000 137000 General Data PKGP-PRC019D-EN 21 Table 6. General data — 12.5 to 25 tons — standard efficiency (DSJ
  • Media type icon

    SS-SVX007B-EN_08022023

    Reference Read/Write Description 22 SS-SVX007B-EN Object Data Points List 9 Night Heat Cool Read 10 Startup Delay Completed Read 11 Cooling Enabled Read 12 CV Mode Active Read 13 VAV Mode Active Read 14 Thermosat Mode Active Read 15 Low OA Temp Cutout Read 16 Compressor 1A Command CV Read 17 Compressor
  • Media type icon

    PKGR-PSD009B-EN_09102025

    September 2025 PKGR-PSD009B-EN EarthWise™ Hybrid Dual Fuel Packaged SystemSingle Packaged Dual Fuel, Priority, Convertible5DCZ5024A1060A5DCZ5030A1070A5DCZ5036A1070A5DCZ5042A1090A5DCZ5048A1090A5DCZ5060A1115A Note: Graphics in this document are for representation only.Actual model may differ in
  • Media type icon

    ACC-SVN173F-EN_09152024

    Document Title:CO2 Sensing Kit Foundation™ Packaged Rooftop Units 3 to 5 & 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    CO2 Sensing KitFoundation™ Packaged Rooftop Units3 to 5 Tons15 to 25 Tons Installation Instructions September 2024 ACC-SVN173F-EN Model Numbers: Used With: BAYCO2K300*, ASYSTAT900* Foundation Wall Mounted SensorBAYCO2K301*, ASYSTAT901* Foundation Duct Mounted Sensor SAFETY WARNINGOnly qualified
  • Media type icon

    RT-PRC078H-EN_12032022

    table notes.2. MBh = Total gross capacity3. SHC = Sensible heat capacity RT-PRC078H-EN 19 Table 4. Gross cooling capacities 4 tons - E/GBC048A3,4,W,K CFM EntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F
  • Media type icon

    RT-PRC128A-EN_01122025

    sea level. General Data 18 RT-PRC128A-EN Performance DataGross Cooling CapacitiesTable 5. Gross cooling capacities 7.5 tons CFMEntDB (°F) Ambient Temperature (°F) Ambient Temperature (°F) Ambient Temperature (°F) 85 95 105Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp (°F) Entering Wet Bulb Temp
  • Media type icon

    FNR-PSD015A-EN_07012025

    Upflow/Downflow/Horizontal Gas-Fired, 1–Stage Non-Condensing Induced Draft Furnaces with High Efficiency Motor July 2025 FNR-PSD015A-EN A801X040BM2SDBA801X060BM4SDBA801X080BM4SDBA801X080CM5SDBA801X100CM5SDBA801X120DM5SDB Notes: • Graphics in this document are for representationonly. Actual model
  • Media type icon

    SS-PRC052C-EN_03142026

    Document Title:Split System Air Conditioners Odyssey™ with Symbio™ Controls R–410A Dry Charge, Heat Pump Condenser 6, 7.5, 10, 15 and 20 Tons, 60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-03-14
    (F) Capacity Curve - Condensing Unit Only 65F75F85F95F105F115F125F COM PRES SOR HIG H S UCT ION LIM IT ID C OIL FRO ST L IMIT Performance Data 36 SS-PRC052C-EN Table 20. Gross cooling capacities (MBH) 6 tons TWA0724*D condensing unit only (IP) Outdoor Temp(°F) Saturation Suction Temperature (°F) 30