Search Results: 18-CH94D1-1C-EN

Showing 1,701 - 1,710 of 7,187 results

Display results per page.
  • Media type icon

    MS-SVN061C-EN_06122020

    Document Title:Installer's Manual - Split System (R-410A) 23 Series Single Zone Inverter System 4TXK23/4MXW23
    Publication Type:Installation
    Publication Date:2020-06-22
    -SVN061C-EN WARNING This equipment is to be serviced by professionally trained personnel ONLY. Under NO circumstances should an unqualified person service it. This equipment contains refrigerant under PRESSURE and operates at HIGH VOLTAGE. Improperly installed, adjusted or altered equipment by an
  • Media type icon

    BAS-SVP066B-EN_04132024

    Document Title:BACnet® and Modbus™ Integration to Voyager™ 3 Packaged Rooftop Air-Conditioners with Symbio™ 700 Controls
    Publication Type:Integration Guide
    Publication Date:2024-04-13
    Figure 12. Communication wiring Protocol Configuration 18 BAS-SVP066B-EN BACnet Points ListObject Naming Conventions The communicated points for the Symbio™ controllers are generally named according to their function.While many of the points are read-only, others include both read and write capability
  • Media type icon

    MC-SLB005-EN_05202020

    Document Title:High efficiency inverter systems - 4MXW/4MYW 9-24 MBH-up to 18 SEER-60Hz
    Publication Type:Sales Brochure
    Publication Date:2020-05-20
    High Efficiency Inverter Systems4MXW/4MYW 9-24 MBH-up to 18 SEER-60Hz 50dB(A) Quiet office 40dB(A) Quiet reading room 30dB(A) Quiet language laboratory 20dB(A) Speak in low voice at 1.5m away *Indoor sound level of the 9 MBH systems measured at low speed 26dB(A) Trane Time(t) Trane ºC OthersRoom
  • Media type icon

    BAS-PTS017A-EN_11152024

    Diagnostics 18 Symbio™ 800 Integration Points ListBACnet®Series R® Model RTWD Date: 11/15/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Object StatesBI-11161 Diagnostic: AFD Failure to Arm or Start 2B 0 = Normal 1 = In Alarm BI-11162 Diagnostic: AFD Fault 1A 0 = Normal1 = In Alarm BI
  • Media type icon

    1213-3652C_10072020

    Document Title:FOUNDATION DIAGRAM SCHEMATIC, POWER - ELECTROMECHANICAL COOLING ONLY WITH VFD - 15-25T
    Publication Type:Wiring Diagram or Manual
    Publication Date:2020-10-07
    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 LEGENDDEVICE DESIGNATION DESCRIPTION LINENUMBER CC1 CONTACTOR - COMPRESSOR 1 8,12,13,14CC2 CONTACTOR - COMPRESSOR 2 16,17,18
  • Media type icon

    12134353_C_09012022

    Document Title:IPAK1 POWER SCHEMATIC 20-75T AIRFLOW, WITH BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    200AD 200AD 200AF 200AF 200AG 200AG 200CU 200CU 200AK 200AK 200AN 200AN(W) 200AZ 200AZ 200C(W) 200C(W) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 THIS DRAWING IS PROPRIETARYAND
  • Media type icon

    REFR-SLB006-EN_09182024

    Document Title:Refrigerant Transition Overview - Buildings need to do better for the planet. And they will.
    Publication Type:Sales Brochure
    Publication Date:2024-09-18
    /system/files/documents/2023-10/technology-transitions-final-rule-fact-sheet-2023.pdf https://www.federalregister.gov/documents/2023/12/26/2023-28500/phasedown-of-hydrofluorocarbons-technology-transitions-program-residential-and-light- commercial-air REFR-SLB006-EN 09/18/2024 Do we need to change the way
  • Media type icon

    22-1753-06_04012009

    filter • Easy access electrical controls and hook-up • 200/230 volt primary and 24 volt secondary transformer • Built-in indoor fan delay function for increased efficiency. No kit required. 22-1753-06 3 Contents Features and Benefits 2general Data 4Performance Data 9Electrical Data 10Dimensions 18 4
  • Media type icon

    HDWA-PRC004E-EN_06192026

    Document Title:Agility® Water-cooled Chillers With Symbio™ Controls
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-06-19
    June 2026 HDWA-PRC004E-EN Product CatalogAgility® Water-cooled ChillersWith Symbio™ Controls175 to 800 Tons (615 to 2813 kW), 60 Hz Model: HDWA HDTA ©2026 Trane HDWA-PRC004E-EN IntroductionCompact Size Without CompromiseCompact – The Agility® chiller portfolio provides an enhanced footprint that
  • Media type icon

    5071-2758A_01112021

    Document Title:CenTraVac® Schematic Energy Meter Option Medium Voltage Starter, Single Stage PT
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-01-11
    AUTRE CONDUCTEUR AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT AutoCAD SHX Text PEUT ENDOMMAGER L'蒕UIPEMENT. AutoCAD SHX Text TYPES DE CONDUCTEURS. AutoCAD SHX Text EN CUIVRE! AutoCAD SHX Text SI NO LO HACE, PUEDE OCASIONAR AutoCAD SHX Text TILICE 贜ICAMENTE CONDUCTORES AutoCAD SHX Text LAS