Search Results: 18-CH83D1-1B-EN

Showing 1,631 - 1,640 of 7,142 results

Display results per page.
  • Media type icon

    2309-4869G_02242022

    PLATED CONTACTS ARE RECOMMENDED. 16 18 20 21 25 26 12. 13. 15. THE POWER WIRING LUG SIZE PROVIDED ON THE VARIOUS FLOW SWITCH & INTERLOCK CONTACTS MUST BE ACCEPTABLE FOR USE IN27 THE FIELD PROVIDED INDICATORS MAY BE RELAYS, LIGHTS OR AUDIBLE DEVICES. BE CONNECTED TO EITHER OR BOTH OF THE NORMALLY OPEN
  • Media type icon

    2311-0023C_03092022

    DUTY, OR 1/3 HP, 7.2 FLA AT 120 VOLTS , CUSTOMER SUPPLIED CONTACTS FOR ALL CLASS 2 CONNECTIONS MUST BE SILVER OR GOLD PLATED CONTACTS ARE RECOMMENDED. 16 18 20 21 25 26 12. 13. 15. FLOW SWITCH & INTERLOCK CONTACTS MUST BE ACCEPTABLE FOR USE IN27 THE FIELD PROVIDED INDICATORS MAY BE RELAYS, LIGHTS OR
  • Media type icon

    BAS-SVX27B-EN_11012009

    Document Title:APOGEE Communications Protocol Operating Instructions - TR200
    Publication Type:Installation Operation and Maintenance
    Publication Date:2009-11-01
    Rev. 2009-01-06130R0454 MG12O102 *MG12O102* APOGEE® CommunicationsProtocol Operating Instructions November 2009 TR200 A BAS-SVX27B-EN Trane has a policy of continous product and product data improvement and reserves the right tochange design and specifications without notice. www.trane.com For more
  • Media type icon

    MS-SVN052E-EN_05032017

    Document Title:U-Match DC Inverter System R-410A Up To 16 SEER Outdoor Unit - Cooling Only and Heat Pump 24,000 to 60,000 BTU/h - 60Hz / IOM
    Publication Type:Installation
    Publication Date:2017-05-03
    : GRILL APPEARANCE MAY VARY DISCHARGE AIR: ALLOW 60” (1.5m)MINIMUM CLEARANCE INCOMING AIR DAMPER WITHVENTS: ALLOW 18” (0.45m)MINIMUMCLEARANCE W SUCTION LINECONNECTION LIQUID LINECONNECTION SERVICE CONNECTOR SERVICE ACCESSALLOW 24”MINIMUM CLEARANCE MS-SVN052E-EN 7 Unit Installation Unit Installation
  • Media type icon

    TEMP-SVN012A-EN_04262025

    value setting. • Depending on the fan selection switch position on the control cabinet door fan mode is VFD or BYPASS (soft start). Modes of Operation 18 TEMP-SVN012A-EN Mode Sequence of Operation LEAD/FOLLOW • Units ship with a yellow communication cable (field-installed). The cable has two, five
  • Media type icon

    RT-SVX087D-EN_01172026

    Document Title:IntelliPak 2 Commercial Rooftop Air Conditioners
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-01-17
    Bypass andPiezometerM = Low CFM Return with VFD with Bypass andPiezometerN = Std CFM Return with VFD without Bypass andPiezometerP = Low CFM Return with VFD without Bypass andPiezometer 8 RT-SVX087D-EN Digit 18 — Relief/Return Fan Motor Selection 0 = NoneD = 7.5 HpE = 10 HpF = 15 HpG = 20 HpH = 25
  • Media type icon

    PRGG-SVX002C-EN_04112026

    monitors thistemperature. Sequence of Operations 18 PRGG-SVX002C-EN When sufficient non-condensables have accumulated inthe purge tank to decrease the compressor suctiontemperature below the pump-out initiate value, a pump-outcycle begins. The cycle is terminated when the compressorsuction temperature
  • Media type icon

    EDU-SLB073-EN_05182026

    Document Title:Data Center Product and Offering Line Card - Turning Thermal Management Strategies Into Growth Strategies
    Publication Type:Sales Brochure
    Publication Date:2026-05-18
    heat-intensive AI factories while optimizing floor space. Features include integrated ATS with supercapacitor, 25-micron filtration, up to 1,350 kW cooling capacity in a compact 900 mm footprint, and front and back service access. © 2026 Trane. All Rights Reserved | EDU-SLB073-EN | 05/18/2026 All
  • Media type icon

    DL-SVN013A-EN_12012018

    Document Title:Split-type Air Conditioners Installation Manual
    Publication Type:Installation
    Publication Date:2018-12-01
    �� 1-18/32 ��� ���� 46 C46 175 @66 ��� ���� JA6 JJ6 349~ 371 ��� ��� 8G56 / 85 �� ��� ���� '�� � ���� �� ������ 9(: ������ ��������������� ���� 9� ���������� ���� ���� �� � ���� ��� ���� ������� ��� ������ #��� ��� I��� �������� 9(: (� �� ��/�� ����� ���� � ��������� 9 : &��� � ���� ����� �� ��� 9E
  • Media type icon

    TEMP-PRC009A-EN_04152025

    Document Title:Trane Rental Services - Temporary Water-Cooled Chillers
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-04-15
    Type Star/Wye-Delta LRAY 624 A Table 21. Dimensions and weights Labels ValueLength 20 ft. Width 7 ft. 6 in. Height 9 ft. 6 in. Shipping Weight 19,000 lbs Operating Weight 21,513 lbs 18 TEMP-PRC009A-EN 225 to 1000 Tons CVHF Lifting Device Crane Table 22. Installed/Operating clearances Labels