Search Results: TEMP-PRC013A-EN

Showing 1,411 - 1,420 of 7,117 results

Display results per page.
  • Media type icon

    DLR-SVN003A-EN_05012025

    Document Title:Variable Speed Side Discharge HP 2-4 Ton R454B
    Publication Type:Installation
    Publication Date:2025-05-01
    DLR-SVN003A-EN 5HCL9024A1000A5HCL9036A1000A5HCL9048A1000A5HCL6024A1000A5HCL6036A1000A5HCL6048A1000A Variable Speed Side DischargeHP 2-4 Ton R454B Installer’s Guide Note: “Graphics in this document are for representation only. Actual model may differ in appearance.” May 2025 SAFETY WARNINGOnly
  • Media type icon

    SO-SVN021A-EN_08312023

    Document Title:Location of Parts for Commercial Self-Contained R'Newal Service Program
    Publication Type:Installation
    Publication Date:2023-08-31
    SO-SVN021-EN.book August 2023 SO-SVN021A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly
  • Media type icon

    SO-SVN025A-EN_08312023

    Document Title:Brushless DC Motor Upgrade for UniTrane Fan-Coil and Force-Flo Air Conditioners
    Publication Type:Installation
    Publication Date:2023-08-31
    SO-SVN025-EN.book Brushless DC Motor Upgradefor UniTrane™ Fan-Coil andForce-Flo™ Air Conditioners Installation Instructions August 2023 SO-SVN025A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating
  • Media type icon

    22-1666-09_05012015

    Document Title:Trane Product Data Upflow/Horizontal Right or Left Induced Draft Gas Furnace XB80 Models TUE1
    Publication Type:Product Data
    Publication Date:2015-05-01
    ) .......................................................................................................BAYFLTR206 [ ] 6 Pub. No. 22-1666-09 PRODUCT SPECIFICATIONS 1MODEL TYPE RATINGS 2Input BTUHCapacity BTUH (ICS) 3AFUE (ICS)Temp. rise (Min.-Max.) °F. BLOWER DRIVEDiameter - Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor
  • Media type icon

    18-HE71D1-8B-EN_05272024

    Document Title:Installers Guide, Crankcase Heater, Models BAYCCHT101, BAYCCHT102, BAYCCHT404, BAYCCHT103, BAYCCHT405
    Publication Type:Installation
    Publication Date:2024-05-31
    Installer’s Guide 1 MODEL: 18-HE71D1-8B-EN Crankcase Heater ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. HAZARDOUS
  • Media type icon

    PART-SVN86C-EN_08182020

    Document Title:Replacement of VariTrane™ and VariTrac™ Control Modules
    Publication Type:Installation
    Publication Date:2020-08-18
    by an unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. © 2020 Trane Models: VariTraneVariTracBRD04939 August 2020 PART-SVN86C-EN Installation
  • Media type icon

    1213-4721_A_02142023

    Document Title:Schematic; Sheet 2, Power, Single Indoor Fan, 2-Stage Gas Heat, 230V, with Supply VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-14
    -NEG(R) TXD-POS(BK) BLACKRED BROWN BROWN DRAIN SPL-16 SPL-17 SPL-18GND(BR) DRAIN BLACK BROWNRED 123 FD IP L1 L2 L3 IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON
  • Media type icon

    1213-4722_A_02142023

    Document Title:Schematic; Sheet 2, Power, Single Indoor Fan, 2-Stage Gas Heat, 460V, with Supply VFD
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-14
    ) SD(BL) RES(R) S1(R)S2(R) SPL-15 S-IN(R) PPF85 123 PPF185 123 BKR MODBUS 3A123 RXD-NEG(R) RXD-POS(BK) TXD-NEG(R) TXD-POS(BK) BLACKRED BROWN BROWN DRAIN SPL-16 SPL-17 SPL-18GND (BR) BLACK BROWNRED 123 FD IP L1 L2 L3 IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN
  • Media type icon

    1213-4828B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, 2-STAGE GAS HEAT, 230V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    SPL-1SPL-2SPL-3 SPL-6SPL-7SPL-8 SEE POWER EXHAUST SCHEMATIC NOTES: IGN 24 VAC OUTADDRESS 1 L1 (IN) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC
  • Media type icon

    1213-4986B_10222024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, 2 STAGE GAS HEAT, 460V STD SCCR, FORWARD CURVE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    ) GROUND COMMONGAS VALVE STAGE 1 FLAME ROD TEMP LIMIT IN ROLLOUT SWITCH IN PRESSURE SWITCH IN L1 (OUT)LOW SPEED (OUT)HIGH SPEED (OUT) MODBUS +MODBUS -COMMON 24 VAC INCOMMON 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT 24 VAC OUT ADDRESS 2 ADDRESS 3 ADDRESS 4 L2 (IN) GAS VALVE STAGE 2