Search Results: 18-CH37D1-3A-EN

Showing 1,321 - 1,330 of 7,117 results

Display results per page.
  • Media type icon

    1213-4963B_09102024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, DUAL COMPRESSOR, SINGLE FAN, VS OUTDOOR FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-10
    & SYMBOL LEGEND TABLES.) OPTIONAL MULTIZONE VAVOPTIONAL HOT GAS REHEAT OPTIONAL HOT GAS REHEAT OR OPTIONS OPTIONAL GAS HEAT OPTIONAL HOTGAS REHEAT CONNECT CUSTOMER SUPPLIED DEVICE TO VHR-TB FOR VENTILATION HEAT OPERATION.VHR RELAY IS ACTIVE WHEN UNIT IS IN HEAT MODE.ELECTRICAL RATING FOR VHR CONTACTS: 3A
  • Media type icon

    1213-4826B_10222024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, SINGLE COMPRESSOR, SINGLE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    IN HEAT MODE. ELECTRICALRATING FOR VHR CONTACTS: 3A @ 277V OPTIONAL HOT GAS REHEAT OR OPTIONS THATREQUIRE CUSTOMER PROVIDED WIRING. P20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18P15 1 2 P191234 P181234 P5 1 2 3 4 5 6 7 8 9 10 11 12P3 1 2 3 4 PPM81123456789 101112 BK/R BK/R BR/B K BR/BK Y/BK Y/BK
  • Media type icon

    BAS-PTS019A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for Air-Cooled Chiller Model CGAM
    Publication Type:Points List
    Publication Date:2024-11-15
    Building Command 0 = Normal1 = In Alarm BAS-PTS019A-ENBinary Input Diagnostics 18 Symbio™ 800 Integration Points ListBACnet®CGAM Date:11/15/2024Reference Document: BAS-SVP083*-EN Object Identifier Diagnostic Name Object States BI - 11156 Comm Loss: Run Command Compressor 1A 0 = Normal1 = In Alarm BI
  • Media type icon

    TEMP-SVX006A-EN_09152024

    \TCCAfans.ran 0.0 2.5 5.0 7.5 10.0 12.5 15.0 0 5000 10000 15000 20000 25000 AHU-10k - Supply Fan [4]-1Comefri ATZAF 20-20 DWDI Class II Centrifugal Air Foil Fan To tal S tatic Pre ssu re ( in H 2O ) Airflow (cfm) RSAU0025F1 AHU TEMP-SVX006A-EN 17 Figure 12. RSAU0025F1 submittal RSAU0025F1 AHU 18 TEMP
  • Media type icon

    RLC-SVX09T-EN_10312025

    ) • Dry nitrogen (20 psig max permachine as needed) Pre-Installation 18 RLC-SVX09T-EN Unit Dimensions and WeightsUnit DimensionsFigure 1. RTWD 80 to 140 tons, 60 Hz 10 9 13 14 15 2 1 3 411 5 6 8 7 12 12 A G H C D E F N RM B J L K N J S E( 3 pass evap ) 2 pass evap 3 pass evap ( 3 pass evap ) (3 pass
  • Media type icon

    PART-SVN149B-EN_05152020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16328, Model Numbers: CVHE / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-15
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Number:CVHE May 2020 PART-SVN149B-EN
  • Media type icon

    PART-SVN151B-EN_05152020

    Document Title:Location of Parts - Motor Change Out Kit, KIT16330, Model Numbers: CVHE / Installation Instructions
    Publication Type:Installation
    Publication Date:2020-05-15
    , adjusted or altered equipment by an unqualified person could result indeath or serious injury. When working on the equipment, observe all precautions inthe literature and on the tags, stickers, and labels that are attached to theequipment. © 2020 Trane Model Numbers:CVHE May 2020 PART-SVN151B-EN
  • Media type icon

    18-HE139D1-1A-EN_11272024

    Document Title:Installer's Guide -Horizontal Economizer and Rain Hood: BAYECON205A, BAYECON206A and BAYRLAY004B
    Publication Type:Installation
    Publication Date:2024-11-29
    voltage supply through wire leads. The economizer is fully accessible through an access panel. Use care when inserting the economizer in the return air compartment, to prevent damaging the foil faced insulation. 18-HE139D1-1A-EN Installer’s Guide ALL phases of this installation must comply with NATIONAL
  • Media type icon

    TF-SVX007B-EN_10312025

    /Heat Pump Description 10 TF-SVX007B-EN General DataTable 2. General data - Thermafit™ MWC chillerCapacity (Tons) 15 20 25 30 40 50 60 80 General Unit Number of IndependentRefrigeration Circuits Dual Dual Dual Dual Dual Dual Dual Dual R-454B Refrigerant Charge(lbs/module) 12 14 16 18 30 36 44 52 R
  • Media type icon

    IAQR-SVX002B-EN_07092025

    Document Title:Dehumidifier – 5DHUM098/5DHUM120
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-09
    HVAC Accessory Connect the accessory to theDMPR (or COM) and 24Vterminals Note: 18 gauge wire needed between the Dehumidifier and the externalcontrol. Controls 16 IAQR-SVX002B-EN Air FiltrationThe dehumidifier is equipped with a MERV-13(Dimensions: 1.75 inches x 14.00 inches x 17.50 inches)filter. The