Search Results: 18-CH37D1-3A-EN

Showing 1,061 - 1,070 of 7,119 results

Display results per page.
  • Media type icon

    1213-3272B_12162019

    DEVICE DESIGNATION DEVICE LOCATION DESCRIPTIONEDC 1B SWITCH-DEFROST CONTROLIDM 1A MOTOR-INDOOR FANRB 2B RELAY BOARD TNS3 1A TRANSFORMER 24VACOM 3A OPTIONS MODULEF 2A FAN CONTACTOR CONDUCTOR NUMBER BASE COLOR TRACER COLOR1 BLACK2 RED3 BLUE4 ORANGE5 YELLOW6 BROWN7 RED BLACK8 BLUE BLACK9 ORANGE BLACK
  • Media type icon

    IAQR-SVX001B-EN_07092025

    Document Title:Dehumidifier – 5DHUM70
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-09
    voltage control must be used with the dehumidifier. Terminal Block ControlOperationCON 24VAC power transformer neutral side FAN Fan control 24V Transformer high side DEHU Dehumidification (fan andcompressor) control 18 IAQR-SVX001B-EN Float External low voltage float switch orwater sensor (use normally
  • Media type icon

    RLC-PRC071A-EN_02132026

    Management Equipment. • UL94-5V, Flammability. • FCC CFR Title 47, Part 15.109: Class A Limit, (30 MHz—4 GHz). • CE EMC Directive 2004/108/EC. Controls 18 RLC-PRC071A-EN Electrical DataElectrical Data TablesTable 1. Electrical data Unit Size Rated Voltage Unit WiringMotor DataSingle Point Power – 1
  • Media type icon

    ACC-SVN303A-EN_09152024

    Document Title:0 to 100% Downflow Dry Bulb Economizer Foundation™ Packaged Cooling and Gas/Electric 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    . Figure 16. Remove duct cover Figure 17. Remove block-off Figure 18. Remove connecting rods Figure 19. Switch return air assembly from Trane to Carrier 10 ACC-SVN303A-EN Installation 7. Attach return duct cover (7) to Trane return air inlet. See Figure 21. 8. If barometric or power exhaust is not
  • Media type icon

    SS-SVN017D-EN_03142026

    capacitance between conductor and shield: < 200 pF/m• Foil or braided shield is acceptable• Wire diameter: 22 to 18 AWG SS-SVN017D-EN 17 Condenser and Air Handler PairingsTable 8. Model number descriptions TWE Air Handler with Symbio Digit 15 — Controls 1 = Constant VolumeC = 2–SpeedD = Single Zone VAV
  • Media type icon

    ARTC-SVX007B-EN_08152024

    separators, and oil filters). 18 ARTC-SVX007B-EN Operating ProceduresOperator InterfaceThermafit™ TACW modular water-cooled units arecomplete chillers that can work on their own or workcollaboratively, in banks of up to 8 units. Chiller PanelsThere are two different electrical panels used in the
  • Media type icon

    18-4045-01_03012018

    Document Title:Trane Supply 2018 Spring Stock Up Catalog - $35.00 per Package of 10 - SOLD IN PACKAGES OF 10
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2018-03-01
    SPRING STOCK-UP20 18 RIGHT PARTS.RIGHT NOW.RIGHT PARTS.RIGHT NOW. 2018_spring_stockup_coverTS.indd 1 1/29/2018 4:11:25 PM
  • Media type icon

    18-HB13D7-7_06012009

    Document Title:Installer's Guide Supplementary 1400 Series Electric Heaters for Air Handler Installations.
    Publication Type:Installation
    Publication Date:2009-06-01
    control box. 18-HB13D7-7 HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICINGWARNING: 05/09 Page 2 INSTALLER'S GUIDE 18-HB13D7-7 BAYHTR -- HEATER DATA HeaterModel No. Numberof CircuitsPhase 240 VOLT 208 VOLT Capacity HeaterAmps per Circuit Capacity Heater Amps per CircuitKW BTUH KW BTUH BAYHTR1405
  • Media type icon

    18-CH88D1-1_02262021

    Document Title:Installer's Guide KIT17922
    Publication Type:Installation
    Publication Date:2021-03-02
    TO 0 VOLTS. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Sharp Edge Hazard. Be careful of sharp edges on equipment or any cuts made on sheet metal while installing or servicing. Personal injury may result. 18-CH88D1-1 CAUTIONThe IFC is polarity sensitive
  • Media type icon

    18-CH89D1-1_02262021

    Document Title:Installer's Guide KIT17923
    Publication Type:Installation
    Publication Date:2021-03-02
    DISCHARGE TO 0 VOLTS. FAILURE TO FOLLOW THIS WARNING COULD RESULT IN PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. CAUTIONSharp Edge Hazard. Be careful of sharp edges on equipment or any cuts made on sheet metal while installing or servicing. Personal injury may result. 18-CH89D1-1 CAUTIONThe IFC is