Search Results: 18-HE82D1-2B-EN

Showing 1,041 - 1,050 of 7,186 results

Display results per page.
  • Media type icon

    RT-PRC130B-EN_05162026

    Document Title:Foundation™ Packaged Rooftop Units Cooling and Gas/Electric 7.5 to 12.5 Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-05-16
    or Max Circuit Breaker Min Circuit Ampacity Max Fuse Size or Max Circuit Breaker 7.5 E/GDK090* 208-230 35 45 39 50 8.5 E/GDK102* 208-230 38 45 45 50 10 E/GDK120* 208-230 50 60 52 60 12.5 E/GDK150* 208-230 62 80 64 80 7.5 E/GDK090* 460 18 20 23 25 8.5 E/GDK102* 460 20 25 27 30 10 E/GDK120* 460 28 30
  • Media type icon

    PKGR-SVX008B-EN_10062025

    Document Title:Installation and Operations Manual - Single Packaged Cooling/Electric Heat, Choice, Convertible, 2 – 5 Ton, R-454B, 5TCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    RAIN SHIELD FLEXIBLE DUCT CONNECTORS OUTDOORAIR DISCHARGE SUPPORT PADFOUNDATION 3/4” VIBRATION ISOLATORS, USE7 ISOLATORS 18 PKGR-SVX008B-EN Figure 4. Converting horizontal to down airflow Lifting and Rigging WARNINGImproper Unit Lift!Failure to properly lift unit in a LEVEL position couldresult in
  • Media type icon

    AFDJ-PRC001B-EN_03172020

    AFDJ-PRC001-EN.book Remote-Mounted Medium Voltage Air-Cooled Adaptive Frequency™ Drive with Tracer AdaptiView™ Control March 2020 AFDJ-PRC001B-EN Product Catalog ©2020 Trane AFDJ-PRC001B-EN Introduction Improve efficiency and maximize profitability with a single solution for all your motor control
  • Media type icon

    ODR-SVN009B-EN_07242026

    Document Title:Integrated Variable or Multi-Speed Control Drive Replacement
    Publication Type:Installation
    Publication Date:2026-07-24
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Returning the Drive Board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table of Contents ODR-SVN009B-EN 7 General InformationImportant: These instructions do not cover all system variations or possible installation issues. For
  • Media type icon

    ACC-SVN208G-EN_08232024

    Document Title:Horizontal and Downflow Standard Economizer — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    18. Install block-off angle Figure 19. Apply gasket Economizer Filter Rack Gasket Figure 20. Mist eliminator servicing Mist EliminatorMist Eliminator Bracket ACC-SVN208G-EN 11 Installation Minimum Position SettingTo adjust the minimum position setting and check out the economizer, the power must be
  • Media type icon

    RT-SVX51N-EN_08232024

    UNIT 123 1/8” 5 15/16” 20 3/16” 18 5/16”(20 5/8” FOR LOW LEAK) 589 3/8”(5 3/8”FOR LOW LEAK) BAROMETRICRELIFE FAN 68 3/8” 86 15/16” 7 3/4” 13 5/8” BAROMETRICRELIFE ECONOMIZER ORMOTORIZED DAMPER HOOD Dimensional Data RT-SVX51N-EN 15 Figure 10. Cooling with optional electric heat — manual damper
  • Media type icon

    12134653_B_02202023

    Document Title:IPAK 2 CONTROLS SCHEMATIC 90-150T 90-150T VARIABLE SPEED REFRIGERATION SYSTEM #1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    (BK)413B(BK) 412B(BK) 412B(BK) 411B(BK) 411B(BK) 1XP47 1XP58 1XP59 408B(BK)407B(BK) 1XP192 NOTES: WIRING SHOWN FOR 90-105T UNITS. SEE INSET A FOR 120-150T UNITS. HOT GAS BYPASS P P P P M M2 LN M1 1234 1COMP 1A 2GND (N) 3COMP 1B 4GND (N) 1COMP 2A 2GND (N) 3COMP 2B 4GND (N) 1COMP 1C 2GND (N) 3COMP 2C
  • Media type icon

    BAS-SVX20K-EN_04152020

    Document Title:Tracer® UC400 Programmable Controller
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-15
    . • Analog outputs: check that no A/C voltage is present and that the load has no 24 Vac across itor 120 Vac. WWiirriinngg 18 BAS-SVX20K-EN Point Check DiagramThis section shows diagrams and describes methods to check device input/output points beforethe connection to the UC400 controller has been made
  • Media type icon

    RRU-SVX01F-EN_11012021

    Clearances Figure 8. Unit dimensional data 12.5-, 15-, and 20-ton high efficiency 18 RRU-SVX01E-EN Unit Weight/Rigging Rigging Refer to Figure 9 and Table 1 for typical unit operating weights rigging before proceeding. 3. Remove the shipping crate from around the unit. Do not remove the crating from the top
  • Media type icon

    PKGR-SVX006B-EN_10062025

    Document Title:Installation and Operations Manual - EarthWise™ Hybrid Dual Fuel Packaged System, Single Packaged Dual Fuel, Priority, Convertible, 2 - 5 Ton, 60 - 115 KBTU, R-454B, 5DCZ5
    Publication Type:Installation
    Publication Date:2025-10-06
    construction materials and must be evaluated byinstaller. Review Location and Recommendation Information 18 PKGR-SVX006B-EN Refrigerant Leak Detection SystemFor all tables contained in this section of the manual, therefrigerant charge is the total system charge which ismarked on the unit nameplate