Search Results: TEMP-SVX005C-EN

Showing 101 - 110 of 7,117 results

Display results per page.
  • Media type icon

    COIL-PRC002M-EN_12012025

    220 5/8in. —— Coil Applications 10 COIL-PRC002M-EN Table3. Heatin gandcoolingwater coils (con tinued) Coil CoilType CoilD rawing Features Row sFinn edWidth FinSp acing perF oot Finn edLeng thTube Material Max.Std. Operatin gCon ditio ns(a) Tube dia (inch) App lication Press PSI Temp °FHeat Coo l P4
  • Media type icon

    18-AC131D1-1A-EN_04232024

    Document Title:Trane Installation and Operation Manual - Condensing Units - 5TTA3036 - 060
    Publication Type:Installation
    Publication Date:2024-04-23
    temperature is above 55º F. LIFT STEP 1 - Use the refrigerant line total length and lift measurements from Section 5.3. Total Line Length = __________ Ft. Vertical Change (Lift) = __________ Ft. 14.2 Subcooling Charging in Cooling (Above 55º F Outdoor Temp.) 18-AC131D1-1A-EN 13 Design Subcooling Value
  • Media type icon

    TEMP-SVN009A-EN_05122024

    Document Title:Trane Rental Services
    Publication Type:Installation
    Publication Date:2024-05-12
    Switch Fan Selector Switch Start-Up Instructions Trane Rental ServicesRSHX00**F4 Voyager™ May 2024 TEMP-SVN009A-EN TEMP-SVN009A-EN 12 May 2024 (NEW) 13.If needed, disable outdoor damper by turning the Economizer Enable switch to Disable. If leaving Economizer enabled, adjust outdoor damper minimum
  • Media type icon

    TEMP-SLB003-EN_06042025

    Document Title:Trane Rental Services Cold Storage - Precision Temperature Controlled Cold Storage Solutions
    Publication Type:Sales Brochure
    Publication Date:2025-06-04
    TEMP-SLB003-EN_06042025.indd Trane Rental Services Cold Storage units are designed to create and maintain ultra-low temperatures as low as -94°F (-70°C), showcasing the advanced technology that ensures the protection of the most sensitive and valuable cargoes. These units are based on Thermo King’s
  • Media type icon

    TEMP-SLB004-EN_06042025

    Document Title:Trane Rental Services Process Cooling Air-Cooled Industrial Chillers with Scroll Compressors - Nominal Cooling Capacity 3-40 Tons
    Publication Type:Sales Brochure
    Publication Date:2025-06-04
    TEMP-SLB004-EN_06042025.indd Many manufacturing and industrial sites require process cooling to remove heat which increases efficiency of production process and operational effectiveness of equipment. Trane has a line of temporary industrial chillers to support our customers ever changing needs
  • Media type icon

    TEMP-SLB008-EN_01122026

    Document Title:Liquid Load Bank Rentals
    Publication Type:Sales Brochure
    Publication Date:2026-01-12
    BUTTERFLY VALVE FORKLIFT POCKETS & HEAVY-DUTY CASTERS Trane Rental Services offers 24/7 technical support, quotes, availability checks, and emergency dispatch— plus weekend, holiday, and after-hours shipments. 800.755.5115 © 2026 Trane. All Rights Reserved | TEMP-SLB008-EN | 01/12/2026 All trademarks
  • Media type icon

    BAS-PTS038B-EN_09262025

    Document Title:Symbio™ 500 Integration Point List BACnet® Self-Contaned (SWUD*)
    Publication Type:Points List
    Publication Date:2025-09-26
    Reference Document: BAS-SVP087*-EN Object IdentifierObject Name Description Configuration Dependency Read/ WriteUnits Low Limit High Limit AI-1 Space Temperature LocalIndicates the space temperature value from a sensor wired to the controller Unit Controls = Space Control or VAV with Space temp
  • Media type icon

    RT-SVN045A-EN_07152021

    Installation Guide0 to 100% Low Leak Economizer –HorizontalFoundation™ Packaged Cooling and Gas/Electric 7.5 to 12.5 Tons MMooddeell NNuummbbeerrss:: BAYECON356*UUsseedd WWiitthh:: EBC 090-150, GBC 090-150 ©2021 RT-SVN045A-EN IntroductionRead this manual thoroughly before operating orservicing this
  • Media type icon

    UV-PRC003V-EN_06092023

    0.9580 0.97 0.89 Table 15. Airflow through coil JUnit Model 0750Rated cfm 748 38 UV-PRC003V-EN Performance Data Table 16. VUV 075, hydronic heating coils A (1-row / 12 fpi), B (2-row / 12 fpi), C (2-row / 16 fpi) Coil Entering Air Temp, Dry Bulb (°F)Entering Water Temp (°F) Flow Rate (gpm)2 4 6 Total
  • Media type icon

    BAS-PTS031A-EN_12062024

    Document Title:Symbio™ 800 Integration Points List BACnet® for RTAC (CH530)
    Publication Type:Points List
    Publication Date:2024-12-06
    Symbio™ 800 Integration Points ListBACnet®RTAC (CH530) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and