Search Results: 18-CH94D1-1C-EN

Showing 981 - 990 of 7,187 results

Display results per page.
  • Media type icon

    WSHP-PRC035-EN_04122024

    25.5 x 55 x 19.75 25.5 x 55 x 19.75 28 x 68 x 21.75 28 x 68 x 21.75 Compressor type Scroll Scroll Scroll Scroll Scroll Net weight (lbs.) 271 340 318 384 394 Ship weight (lbs.) 395 464 442 529 539 Filter size nominal (in.) 17 x 20 18 x 23 18 x 23 20 x 30 20 x 30 Water in/out size (FPT) 0.75 0.75
  • Media type icon

    PART-SVN271A-EN_05062025

    tube connectionsto the compressor. General Information 12 PART-SVN271A-EN Proceed with the following as described in the followingsections:• “Leak Detection,” p. 17• “Vacuum Testing and Evacuation,” p. 18• “Verification Before Start-Up,” p. 19 Electrical FailureReplace only the failed compressor in a
  • Media type icon

    BAS-PTS016A-EN_11152024

    Symbio™ 800 Integration Points ListLonTalk®Series R® Model RTHD Date:11/15/2024Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number.• Tables are sorted
  • Media type icon

    WSHP-PRC033C-EN_06082026

    Document Title:Water Source Heat Pump Axiom™ Horizontal/Vertical – GEH/GEV* 0.5 to 25 Tons – 50/60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-06-08
    x 2.6 17 x 18.75 x 2.6 18 x 21.75 x 2.6 20 x 28.25 x 2.6 Coil Surface Area (Sq. Ft.) 1.43 1.92 2.21 3.02 3.92 General Data 34 WSHP-PRC033C-EN Table 13. Models GEV/GEH 006-060 (0.5 to 5 tons) air-to-refrigerant coil (continued) Model GEV/GEH 006-012 015-018 024-030 036-042 048-060 Fins per Inch 14
  • Media type icon

    5071-2735B_10102021

    Document Title:CenTraVac® Schematic Symbio800 CVRF Panel Upgrade Classic Black
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-10-10
    Text EN CUIVRE! AutoCAD SHX Text DISE袮DAS PARA ACEPTAR OTROS TIPOS AutoCAD SHX Text LAS TERMINALES DE LA UNIDAD NO EST罭 AutoCAD SHX Text TILICE 贜ICAMENTE CONDUCTORES AutoCAD SHX Text SI NO LO HACE, PUEDE OCASIONAR AutoCAD SHX Text 50712735-B AutoCAD SHX Text DA袿 AL EQUIPO. AutoCAD SHX Text DE COBRE
  • Media type icon

    RT-SLB061-EN_11182024

    RT-SLB061-EN 11/18/2024© 2024 Trane. All Rights Reserved. Trane – by Trane Technologies (NYSE: TT), a global climate innovator – creates comfortable, energy efficient indoor environments through a broad portfolio of heating, ventilating and air conditioning systems and controls, services, parts and
  • Media type icon

    DLR-SVN001A-EN_05012025

    Document Title:Variable Speed Side Discharge HP 2 Ton R454B
    Publication Type:Installation
    Publication Date:2025-05-01
    ] Max. 500 [20] 300 [12] 300 [12] 300 [12] 500 [20] Max. 300 [12] 1000 [40] 1000 [40] 1000 [40] 1000 [40] 1000 [40] 1000 [40] mm [inch] 1000 [40] 150 [6] Fig. 2-6 Fig. 2-8 Fig. 2-9 Fig. 2-10 Fig. 2-12 Fig. 2-14 Fig. 2-15 Fig. 2-16 Fig. 2-17 Fig. 2-18 Fig. 2-7 Fig. 2-11 Fig. 2-13 100 [4] 300 [12] en
  • Media type icon

    RRMA-SVX01A-EN_09012002

    Document Title:Installation Operation Maintenance EnviroPump R11, R123 Patented Chiller Pressurization System Models- RRMA
    Publication Type:Installation Operation and Maintenance
    Publication Date:2002-09-01
    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Table of Contents RRMA-SVX01A-EN 3 GeneralInformation Specifications Electrical Power Requirements • 460/480 VAC, 50/60 Hz, 3-Phase, 20-Amperes Heater. • 120 VAC, 50/60 Hz, 1-Phase, 15-Amperes Controls, Liquid Pump and Vacuum Pump.Dimensions (approximate) • 40” high x 31” wide x 29” deep
  • Media type icon

    COR-SVN005B-EN_11302025

    Document Title:High Efficiency Horizontal, Flat “Cased” Coils, 5PXFH AZ Models
    Publication Type:Installation
    Publication Date:2025-11-30
    "To Outdoor" flag label should bespliced to field provided outdoor wire within the furnacecabinet. Wiring 18 COR-SVN005B-EN Field WiringFigure 11. 24V field wiring diagram for heating thermostat plus AC/HP COR-SVN005B-EN 19 Figure 12. AccuClean or CleanEffects air cleaner plus 24V vac furnace
  • Media type icon

    HCCA-PRC001-EN_03012004

    Document Title:Chilled Water Fan Coil Unit Maxxum Model-HCCA Size 10-24
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2004-03-01
    kW) Heater (Size 10~24)B = 1.5 kW(1.8 kW) Heater (Size 10~24)C = 2.0 kW(2.4 kW) Heater (Size 10~24)D = 2.5 kW(3.0 kW) Heater (Size 10~24)E = 3.0 kW(3.6 kW) Heater (Size 10~24)F = 3.5 kW(4.2 kW) Heater (Size 10~24)G = 4.0 kW(4.8 kW) Heater (Size 14~24)H = 5.0 kW(6.0 kW) Heater (Size 18~24)I = 6.0 kW