Search Results: 18-CH94D1-1C-EN

Showing 981 - 990 of 7,187 results

Display results per page.
  • Media type icon

    AHR-SVX007C-EN_03112026

    Document Title:Variable Speed Air Handlers, Convertible 2 to 5 Ton
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-03-11
    . 18 and Table 6, p. 18. AHR-SVX007C-EN 15 Figure 3. Link communicating low voltage connectiondiagrams Table 2. Wire colors R Red DH White DL Green B Blue Notes:• * — Accessory terminals are dry contact outputs only.• + R connection to the outdoor unit is required only in applications utilizing an
  • Media type icon

    RT-SVX51N-EN_08232024

    UNIT 123 1/8” 5 15/16” 20 3/16” 18 5/16”(20 5/8” FOR LOW LEAK) 589 3/8”(5 3/8”FOR LOW LEAK) BAROMETRICRELIFE FAN 68 3/8” 86 15/16” 7 3/4” 13 5/8” BAROMETRICRELIFE ECONOMIZER ORMOTORIZED DAMPER HOOD Dimensional Data RT-SVX51N-EN 15 Figure 10. Cooling with optional electric heat — manual damper
  • Media type icon

    12134386_B_09012022

    Document Title:COMPONENT LAYOUT; 90-130T MAIN C-BOX / AUX C-BOX
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    - COMPRESSOR 1B 8151QA9 CONTACTOR - COMPRESSOR 2A 8151QA10 CONTACTOR - COMPRESSOR 2B 8151QA11 CONTACTOR - CONDENSER FAN 1A 7851QA12 CONTACTOR - CONDENSER FAN 1B 7851QA13 CONTACTOR - CONDENSER FAN 1C / 1D 7851QA14 CONTACTOR - CONDENSER FAN 2A 7851QA15 CONTACTOR - CONDENSER FAN 2B 7851QA16 CONTACTOR
  • Media type icon

    MS-SVN047B-EN_12152015

    Document Title:Split System (R-410A) Inverter Unit 16 to 18 SEER 9,000 to 24,000 BTU/Hr - 50/60 Hz / Installation Manual
    Publication Type:Installation
    Publication Date:2015-12-15
    wiring installation and grounding as described in the National Electrical Codes (NEC) and your local/state electrical codes. All field wiring must be performed by qualified personnel. Failure to comply with these requirements could result in death or serious injury. . 18 MS-SVN047B-EN Wiring Diagrams
  • Media type icon

    ODR-PSD039A-EN_12132025

    ODR-PSD039A-EN_12132025 December 2025 ODR-PSD039A-EN Air Conditioner with WeatherGuard™5TTX6018A1000A5TTX6024A1000A5TTX6030A1000A/B5TTX6036A1000A/B5TTX6042A1000A/B5TTX6048A1000A/B5TTX6060A1000A/B Note: Graphics in this document are for representation only.Actual model may differ in appearance
  • Media type icon

    BAS-SVX092D-EN_01102026

    Document Title:Symbio™ 400–B/500 Programmable Controllers Water Source Heat Pump (WSHP)
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-01-10
    BO9 Outdoor Air Damper Typical Applications and Terminations 18 BAS-SVX092D-EN Table 6. Factory programmed terminations for single compressor control for Trane EX/DX units (continued) Inputs/Outputs/Communication Symbio 400–B/500 ControllerTerminations Factory Programmed Assumed Terminations Analog
  • Media type icon

    PART-SVN116A-EN_06012009

    Document Title:Variable Frequency Drive Conversion to TR200 IntelliPak™ and Voyager™ III only
    Publication Type:Installation
    Publication Date:2009-06-01
    CONNECTOR CBL VFD-6VFD-6 KEYPADSUPPLY VFD-2VFD-2SUPPLYSUPPLY PP24PP24 PP22PP22SUPPLY VFD-9VFD-9SUPPLY TNS8TNS8 410A 205C412A206C TB1TB1 TB2TB296 TB 1K42 13 w/o Bypass 18 PART-SVN116A-EN Installation of TR200 VFD and Components Connect the high voltage control wiring cable on supply fan VFD labeled
  • Media type icon

    BAS-PTS008A-EN_11152024

    Symbio™ 800 Integration Points List LonTalk®Agility™ Water-cooled Chillers Date: 11/15/2024 Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number
  • Media type icon

    RSP-PRC013-EN_10012001

    Document Title:Prefabricated Roof Accessories For All Systems
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2001-10-01
    Prefabricated RoofAccessories For AllSystems RSP-PRC013-EN 2 RSP-PRC013-EN© 2001 American Standard Inc. All rights reserved. Good roofing practice allows penetration movement independent of the roof. This requires a flexible seal at the penetration andproper attachment to the roof. With the
  • Media type icon

    WSHP-PRC033C-EN_06082026

    Document Title:Water Source Heat Pump Axiom™ Horizontal/Vertical – GEH/GEV* 0.5 to 25 Tons – 50/60 Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-06-08
    x 2.6 17 x 18.75 x 2.6 18 x 21.75 x 2.6 20 x 28.25 x 2.6 Coil Surface Area (Sq. Ft.) 1.43 1.92 2.21 3.02 3.92 General Data 34 WSHP-PRC033C-EN Table 13. Models GEV/GEH 006-060 (0.5 to 5 tons) air-to-refrigerant coil (continued) Model GEV/GEH 006-012 015-018 024-030 036-042 048-060 Fins per Inch 14