Search Results: ED*

Showing 941 - 950 of 1,448 results

Display results per page.
  • Media type icon

    ACC-SVN01R-EN_09152024

    Document Title:0 to 50% Manual Outside Air Damper Precedent™ Packaged Rooftop Units 3 to 12.5 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    screws. See Figure 5. 6. Apply gasket to flanges of side panels. Align the edge of the gasket with the outside edge of the side panel flanges. See Figure 6. 7. Install damper assembly onto the unit. Insert top center screws first, bottom screws into the unit base next, and remaining screws around the
  • Media type icon

    RT-SVX072E-EN_10122024

    restraint equipment thatwill not allow an individual to reach the unit edge.However such equipment will NOT prevent falling tothe ground, as they are NOT designed to withstandthe force of a falling individual. The fall restraint is located approximately 3 feet from theunit edge. Figure 122. Fall
  • Media type icon

    GOV-SLB022-EN_10102024

    Document Title:Making Sense of Federal Procurement Options
    Publication Type:Sales Brochure
    Publication Date:2024-10-10
    methods available within the Government, so you can make educated decisions for how best to support your purchasing needs. Procurement Methods: Government’s Path to PurchaseThe Federal Acquisition Regulations (FAR) is the rule book for Federal Government purchases. There is a wide array of options
  • Media type icon

    RT-PRC111B-EN_08232024

    .) cooling with optional electricheat (electric/electric) units only Tons Unit Model No.Weights (lb)(a) , (b) Corner Weights(c) Center of Gravity (in.) Shipping Net A B C D Length Width3 EDK036* 523 473 87 98 153 135 41 29 4 EDK048* 566 516 103 107 155 150 39 28 5 EDK060* 586 536 112 112 156 156 38
  • Media type icon

    1213-4825B_10222024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, SINGLE COMPRESSOR, SINGLE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    OUTCIRCUIT 2 HPC IN CIRCUIT 2 HPC OUTCOMPRESSOR 2 RUN IN COMPRESSOR 1 UNLOADER OUTGND-A GND-ACOMPRESSOR 2 UNLOADER OUT 24 V AC-A OUT GND- A 24 V AC-A OUT GND- A 24 V AC-A INGN D-A 24 V AC-P INNO T US ED 24 V AC-A OUT 24 V AC-A OUT NOT USED 24 V AC-P IN NOT USED NOT USED NOT USED CIRC UIT 1 PRO VING
  • Media type icon

    1213-4826B_10222024

    Document Title:SCHEMATIC; SHEET 4, CONTROLS, ADAPTER BOARD UNIT CONTROLS, SINGLE COMPRESSOR, SINGLE FAN
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-22
    -ACOMPRESSOR 2 UNLOADER OUT 24 V AC-A OUT GND- A 24 V AC-A OUT GND- A 24 V AC-A INGN D-A 24 V AC-P INNO T US ED 24 V AC-A OUT 24 V AC-A OUT NOT USED 24 V AC-P IN NOT USED NOT USED NOT USED CIRC UIT 1 PRO VING OUT COMP RESS OR 1 ENAB LE IN COMP RESS OR 1 UNLO ADER IN CIRC UIT 2 PRO VING OUT COMP RESS
  • Media type icon

    SO-SVN063A-EN_11162024

    abrasion is occurring from vibrations against chassis of cabinets, or other edges. 4. Confirm the drive interior and exterior is clear of any dust or debris. Fans, circuit boards, vents, etc. must be clean. Only use a vacuum for cleaning. Do NOT use compressed air. 5. Inspect the interior of the drive
  • Media type icon

    BAS-PTS024A-EN_11082024

    Compressor 1B115 nvoStartsRunTmD UNVT_starts_runtime Starts and Run Time – Compressor Ddefined at element ♥SNVT_count_f Starts 1 Starts Compressor 2A SNVT_time_f Run Time 360 sec Running Time Compressor 2A116 nvoStartsRunTmE UNVT_starts_runtime Starts and Run Time – Compressor Edefined at element ♥
  • Media type icon

    BAS-PTS023A-EN_11082024

    Document Title:Symbio™ 800 Integration Points List BACnet®/Modbus™ for Series R® Air- Cooled Chiller Model RTAC
    Publication Type:Points List
    Publication Date:2024-11-08
    by the building automation system (BAS). When used, these points are written internally to arbitration logic. This defines the interaction with hardwired points, editable software configuration points and the relinquish default value/state. Refer to the Appendix for additional information
  • Media type icon

    CLCH-SLB041-EN_06072024

    Document Title:Performance Climate Changer® with Factory-Mounted Symbio® 500 Controls
    Publication Type:Sales Brochure
    Publication Date:2024-06-07
    protecting the casing from potential damage from on-site controls mounting Adds no additional time to the construction of your air handler. Your order proceeds just as rapidly as units without pre-mounted controls Two simple connections.Equipment-to-controls connectivity is simpli�ed down to two power and