    ACC-SVN204F-EN_08232024

    Document Title:Barometric Relief Damper - Foundation™ Units With Low Leak Economizer 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    . Remove panels Remove Panel 2. Build the barometric hood assembly as shown in Figure 4:a. Attach 18 to 20 and 21 using two screws each side.b. Place 17 resting on the bottom flanges of 20 and 21.c. Apply gasket 22 to hood assembly aligning with four edges of the assembly.d. Apply foil tape to cover
  • Media type icon

    ACC-SVN205E-EN_08232024

    Document Title:0 to 100% Low Leak Economizer — Horizontal Foundation™ Packaged Cooling and Gas/Electric 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    screws. Figure 3. 3. Install economizer onto unit. Align edge of both sides of the economizer panel flange with LH and RH side post as shown in Figure 4. Economizer should rest on return base pan as shown. WARNINGHazardous Service Procedures!Failure to follow all precautions in this manual and on the
  • Media type icon

    ACC-SVN207D-EN_08232024

    Document Title:Electric Heat — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    3. Air temperature rise across electric heaters (°F) kW Stages 3 Tons940 CFMEB*036A*ED*036A* 4 Tons1280 CFMEB*048A*ED*048A* 5 Tons1640 CFMEB*060A*ED*060A* 4.7 1 12.38 9.29 7.43 7.5 1 19.76 14.82 11.85 10 1 26.34 19.76 15.81 14.4 1 37.93 28.45 22.76 20 2 – 39.51 31.61 25 2 – – 39.51 Notes: 1. For
  • Media type icon

    ACC-SVN251B-EN_08232024

    Document Title:Crankcase Heater — Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    ties. Care must be taken to ensure the leads do not come in contact with the compressor discharge line, with any moving parts or any sharp edges. 8. Re-install the control and compressor access panel.9. Re-apply power to the unit. Note: Refer Figure 3 for crankcase heater wiring diagram. Figure 2
  • Media type icon

    ACC-SVN174F-EN_08232024

    Document Title:Evaporator Defrost Control Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    . Where local regulations are more stringent than these policies, those regulations supersede these policies. • Non-Trane personnel should always follow local regulations. General InformationThe evaporator defrost control (EDC or Frostat™) is installed in the evaporator (Indoor) coil face area. Its
  • Media type icon

    ACC-SVN185D-EN_08232024

    Document Title:Evaporator Defrost Control Foundation™ Packaged Rooftop Units 3 to 5 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    local representative. General Information• The evaporator defrost control (EDC or Frostat™) is installed in the evaporator (Indoor) coil face area. • The EDC should cycle the compressor when the evaporator frosts under low outdoor ambient cooling conditions or low airflow applications. • The EDC
  • Media type icon

    ACC-SVN168G-EN_08232024

    Document Title:Oversized Motor Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-08-23
    motor securing bolts to 144 to 151 inch pounds (16.3 to 17.1 N-m). Do not attempt to install lead wires until after the motor has been mounted in place. 12.Check alignment of blower sheave and motor sheave using a straight edge, and adjust if necessary. Torque the motor sheave set screw and the fan
  • Media type icon

    RT-PRC125A-EN_09152024

    Net A B C D Length Width 15 EDK180A 2216 1891 629 513 337 413 55 34 17.5 EDK210A 2221 1896 630 514 338 414 55 34 20 EDK240A 2227 1902 628 495 343 435 54 36 25 EDK300A 2263 1938 640 505 350 444 54 36 (a) Weights are approximate. Horizontal and downflow unit and corner weights may vary slightly.(b
  • Media type icon

    RT-PRC127A-EN_09152024

    Disconnect Switch(c) Table 2. 15 to 25 tons packaged rooftop performance data (gas or electric heat)Nominal Size (Ton) 15 17.5 20 25 EDK180 GDK180 EDK210 GDK210 EDK240 GDK240 EDK300 GDK300Cooling Performance(a) (a) Units are AHRI Certified to AHRI Standard 340-360 (I-P). Rating conditions are 95°F
  • Media type icon

    ACC-SVN303A-EN_09152024

    Document Title:0 to 100% Downflow Dry Bulb Economizer Foundation™ Packaged Cooling and Gas/Electric 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    assembly (Carrier configuration) 1 3 Return air damper assembly 1 4 Connecting rod assembly (Trane option) 1 5 Block-off 1 6 Plastic bag of miscellaneous parts: 1 Screws – Edge protector 2 Installation Instructions 1 Table 2. Factory installed component parts list Qty Description 1 Block-off 1 Plastic