Search Results: TEMP-PRC013A-EN

Showing 81 - 90 of 7,121 results

Display results per page.
  • Media type icon

    BAS-PTS033A-EN_12062024

    RTHD (CH530) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Description Units Configuration Dependency Analog Input, 44 Evaporator Entering Water Temp Temperature of the water entering the evaporator. Temperature Analog Input, 45 Evaporator Leaving Water Temp
  • Media type icon

    18-GJ21D1-2B-EN_08212024

    , STATE AND LOCAL CODES 18-GJ21D1-2B-EN Models:BAYWA1705SC1AABAYWA2107SC1AABAYWA2308SC1AA Table of ContentsSection 1. Safety Considerations ...... 2Section 2. General Information .......... 3Section 3. Hydronic Coil Assembly .. 4Section 4. Install Hydronic Coil ......... 5Section 5. Piping
  • Media type icon

    FNR-PSD009C-EN_02272026

    Document Title:Upflow/Horizontal Left/Right, Dedicated Downflow Two Stage Condensing Gas Fired Furnace
    Publication Type:Product and Submittal Data
    Publication Date:2026-02-27
    -PSD009C-EN Airflow TablesTable 4. Heating airflow performance - model S9V2B040U3VS Furnace Heating Airflow (CFM), Power (Watts), and Temp. Rise (°F) vs. External Static Pressure with Filter (iwc) Airflow Setting Heating Stage Target AirflowExternal Static Pressure (In. W. C.) 0.1 0.3 0.5 0.7 0.9 650 1st
  • Media type icon

    PKGP-SVX19A-EN_05052023

    unqualified person could result in death or serious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. Mayo 2023 PKGP-SVX19A-EN Confidential and proprietary Trane information Installation
  • Media type icon

    ODR-SVX011B-EN_04172026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    outside of the unit with apermanent marker. System Charge Adjustment 26 ODR-SVX011B-EN a. Charge added at Factory = ___________ lb/ozb. Charge added at install = ___________ lb/ozc. Total System Charge (a + b) = ___________ lb/oz Subcooling Charging Below 55ºF Outdoor Temp. (In HeatingOnly)The
  • Media type icon

    ODR-SVX010B-EN_04172026

    Document Title:Heat Pumps
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-04-17
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. April 2026 ODR-SVX010B-EN Heat
  • Media type icon

    BAS-SVN028L-EN_08062022

    Document Title:Trane® Commercial Touch Screen Programmable Zone Sensor for ReliaTel™, UC400 and Symbio™ 400/700/800 Controls
    Publication Type:Installation
    Publication Date:2022-08-06
    wired to HVAC equipment. Important: Configure the Temp Sensor parameter as needed. See 2/4 Configuration menu for details. BAS-SVN028L-EN 7 Zone Sensor Wiring ReliaTel™ SystemsThe zone sensor and the BCI-R form a two-node BACnet MS/TP network. Wire the system as shown in the schematic below while
  • Media type icon

    BAS-SVP047B-EN_09092023

    Document Title:BACnet® and Modbus™ Integration to Agility™ Water-Cooled Chillers with Symbio™ Controls
    Publication Type:Integration Guide
    Publication Date:2023-09-09
    Water Pressure 0 = Normal1 = In Alarm BI-11067 Diagnostic: Evaporator Leaving Water Temp Sensor 0 = Normal1 = In Alarm BACnet Points List BAS-SVP047B-EN 21 Table 4. Binary input diagnostics (continued) Object Identifier Object Name Object States BI-11068 Diagnostic: Evaporator Water Flow
  • Media type icon

    BAS-PTS010A-EN_11152024

    Document Title:Symbio™ 800 Integration Points List LonTalk® for CenTraVac™ Simplex/Duplex Water-cooled Chillers with Symbio™ Controls
    Publication Type:Points List
    Publication Date:2024-11-15
    /2024Reference Document: BAS-SVP084*-EN Profile Index Network Variable Name Variable Type Variable Description Recv HrtBt Point Name 24 nviChillerEnable SNVT_switchRequest Start/Stop Chillerx BAS Chiller Auto Stop Command 25 nviCoolSetpt SNVT_temp_pDesired Temp of Lvg Chilled Wtrx BAS Chilled Water
  • Media type icon

    BAS-PTS035A-EN_12062024

    Symbio™ 800 Integration Points List BACnet®RTWD (CH530) Date: 12/6/2024 Reference Document: BAS-SVP083*-EN Object IdentifierObject Name Description Units Configuration Dependency 1 Active Cool/Heat Setpoint Temperature Active chiller water or hot water setpoint. Temperature 2 Active Current Limit