Search Results: TEMP-PRC012A-EN

Showing 711 - 720 of 7,133 results

Display results per page.
  • Media type icon

    SS-SVX014E-EN_03142026

    cleaning of the coil with thepressure washer aimed perpendicular to the face of the coilduring cleaning. Optimum clearance between the sprayernozzle and the microchannel coil is 1-inch to 3-inch. SS-SVX014E-EN 37 Maintenance LogDate Ambient Temp. (°F) Evaporator Enterin gAir Com pressor Superheat(°F
  • Media type icon

    SS-SVX016D-EN_03142026

    training. Improperly installed, adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. March 2026 SS-SVX016D-EN
  • Media type icon

    BAS-SVX58D-EN_08302020

    Document Title:TR150 and TR170
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-08-30
    TR150 and TR170 Quick Guide August 2020 BAS-SVX58D-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training
  • Media type icon

    BAS-SVX54B-EN_08302020

    Document Title:TR200 New D-Frame, 110-400 kW
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-08-30
    Brake IGBT X X 244 Heatsink temp X X X 245 Heatsink sensor X X 246 Pwr.card supply X X 247 Pwr.card temp X X 248 Illegal PS config X X 250 New spare parts X TR200 D-Frame Operating Instructions Warnings and Alarms BAS-SVX54B-EN 59 No. Description Warning Alarm/Trip Alarm/Trip lock Parameter
  • Media type icon

    12134370_B_09012022

    Document Title:CONTROLS SCHEMATIC; 90-130T REF SYSTEM #2
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    - COMPRESSOR 2A 3772E10 CRANKCASE HEATER #2 - COMPRESSOR 2B 3702KF36 MODULE - COMPRESSOR 2A PROTECTION 3692KF37 MODULE - COMPRESSOR 2B PROTECTION 3682S3 SWITCH - HIGH PRESSURE CUTOUT 3692S25 SWITCH - CCH TEMP, COMP 2A 3772S26 SWITCH - CCH TEMP, COMP 2B 371 2XP702XP70 1XP137 BLACK BLACK 1XP137 1XP137 1XP139
  • Media type icon

    1213-4989B_09242024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, LOW NOX GAS HEAT, 230V STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-24
    TERM BLOCK-INDOOR FAN 69IDM1 INDOOR MOTOR 1 75IGN MODULE-IGNITION CONTROL 97IP PROBE-IGNITION CONTROL 107LDS SENSOR-LEAK DETECTION 64PMB PRE-MIX BLOWER 97PS SWITCH-PRESSURE 111TCO1 SWITCH-THERMAL CUT-OUT 1 102TCO2 SWITCH-THERMAL CUT-OUT 2 105TNS4 TRANSFORMER - GAS HEAT 97VTL SWITCH - VESTIBULE TEMP
  • Media type icon

    12134363_B_09012022

    Document Title:IPAK 1 CONTROLS SCHEMATIC 20-75T CUSTOMER CONNECTIONS #1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2022-09-01
    EQUIPMENT STOP 24VDC24VDC24VDC J1 J11 ZONE SENSE J15 J4 J3 J2 J5 1KF10 GND (N) GND (N) GND (N) GND (N) GND (N) GND (N) SPACE HUMIDITY CHANGEOVER MODE INPUT ZONE TEMP HEAT SP COOL SP 24VDC24VDC24VDC J1 J11 ZONE CONTROL J15 J4 J3 J2 J5 901B(BK) 901B(BK) 902B(BK) 902B(BK) 900D(BK) 900D(BK) 903B(BK) 903B
  • Media type icon

    SYS-SLB039-EN_06272024

    Document Title:High Temperature Heat Pump Systems - Plugging HVAC innovation into new or existing buildings
    Publication Type:Sales Brochure
    Publication Date:2024-06-27
    applications. Contact your Trane Account Manager to learn more. Heating Distribution 150°F – 200°F (66°C – 93°C) Medium Temp Heat Source 60°F – 90°F (16°C – 32°C) Low Temp Heat Source 25°F – 60°F (4°C – 16°C) Heating Distribution Up to 200°F (93°C) RTWD Up to 180°F (82°C) CVHH Heat Source/Cooling Load 25°F – 60°F (4°C – 16°C) Heating Distribution Up to 200°F (93°C) RTWD Up to 180°F (82°C) CVHH
  • Media type icon

    1213-4994C_10232024

    Document Title:SCHEMATIC; SHEET 2, POWER, SINGLE INDOOR FAN, LOW NOX GAS HEAT, 460V HIGH SC
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-10-23
    - VESTIBULE TEMP LIMIT 92 GYGY YBR O/G O/G GYGY P8 P12 P10 1AB 2AB(O) 3AB(Y) PPF105 P11PPM166BKBKR ROO PPF167 BL BLBK PPF91 P7 BLBL PPF92 137A (BR) 137A 138A (O) 138A 139A (Y) 139A 140A(G/Y) PPM8912 BR (BR) BR O (O) O 141A(BR)142A(O)143A(Y) 144A(G/Y) BKR BR DRAI N FU36L2 T2 FU35L1 T1 PS TCO1 TCO2 FR
  • Media type icon

    22-1919-1D-EN_06112020

    Product Data22 Series Split System (R-410A)Multi-Zone, Inverter System 18,000 to 42,000 BTU/Hr 22-1919-1D-EN Multi-Zone Outdoor UnitHeat Pump 4TXM2218A12N 4TXM2221A13N 4TXM2224A14N 4TXM2230A15N 4TXM2236A15N 4TXM2242A15N 4TXM6536A1040, , 4TXM6524A1030, 4TXM6530A1040 4TXM6542A1050 2 3 It's Hard to