Search Results: AC-PRC005D-EN

Showing 651 - 660 of 7,151 results

Display results per page.
  • Media type icon

    1213-2583D_10292018

    Document Title:INTELLIPAK - CONTROLS SCHEMATIC, 20T-75T - REFRIGERATION SYSTEMS #1 - WITH VSC
    Publication Type:Wiring Diagram or Manual
    Publication Date:2018-10-29
    VIOLET GY GREY W WHITEO ORANGE Y YELLOW 1TA1POWER SUPPLY(CONDENSER) J1 J2 3 2 1J5 GND 27 V AC (B ) 27 V AC (A ) J4 +24 VDC GND COMM + COMM - J3 1 2 3 4 +24 VDC GND COMM + COMM - 1 2 3 4 +24 VDC GND COMM + COMM - 1 2 3 4 J11+24 VDC GND COMM + COMM - 1 2 3 4 1 2 3 4 1KF2COMPRESSOR CIRCUIT 1 6 5 4 3 2 1
  • Media type icon

    1213-2833F_09302019

    Document Title:INTELLIPAK - SCHEMATIC / LAYOUT; MODULATING GAS HEAT - 850 MBH ULTRA
    Publication Type:Wiring Diagram or Manual
    Publication Date:2019-09-30
    AC C OM NC GND 115V AC FLAM E RO D #1 FLAM E RO D #2 GAS MODULATION - FEEDBACK LIMIT SWITCH IN GAS MODULATION CONTROL COM MAIN GAS VALVE MAIN GAS VALVE COM SPLIT-MANIFOLD GAS VALVE COM SPLIT-MANIFOLD GAS VALVE 24VAC COM AIR PRESSURE SWITCH IN AIR PRESSURE SWITCH OUT GAS MODULATION PWR GAS
  • Media type icon

    12134996B_06132024

    Document Title:POWER SCHEMATIC, 20T-75T - AIRFLOW AND CONTROLS W/ VFD BYPASS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    INPUTS L1 L2 L3VOLTAGE INPUTS 1PG1 UL1 4TB1 GND L2 VL3 W 1S1L1 T1 1TF131TF14 1TF15 1XD4L1 L2 L3 T3T2T1 115VAC1T1 RED WHT GRN BRN ORG 460 V AC 120V2T4 BK W G 575 V AC COM R BR BL T1 T2 L1 L2 2S5 6M14 G 6M15 G 6M16 G L1L2L3 T1T2T3 4FC1 UL1 4TB2 GND L2 VL3 W L1L2L3 T1T2T3 4FC2 6T524V 120V 2QB1/2XD1
  • Media type icon

    DOAS-PRC001N-EN_10312025

    Document Title:CoolSense™ Chilled Water Sensible Cooling Terminal Units
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2025-10-31
    -EN 71 Moisture SensorThe moisture sensor is used to detect the presence ofcondensate in the drip pan located under the sensible coolingcoil, and to provide a relay output. The device operates on 24Volts AC and functions as a Normally Closed Sensor(contacts open upon the detection of moisture). DDC
  • Media type icon

    18-BC54D1-3_02012009

    Document Title:Installer's Guide Heat Pumps Models- 2TWX4 & 2TWX5
    Publication Type:Installation
    Publication Date:2009-02-01
    be set on a level support pad at leastas large as the unit base pan, such as a concrete slab.If this is not the application used please refer toapplication bulletin “XLi-APG**-EN”. (* denotes latestrevision number) 3. The support pad must NOT be in direct contact with anystructure. Unit must be
  • Media type icon

    AH-PRC010A-EN_01082020

    circuit is 24 volts AC, wired in accordance with NEC Class II requirements. Ensure the control circuit wire is not smaller than 18 AWG. All wiring is neatly wrapped and routed in bundles. Each wire ends with a AH-PRC010A-EN 39 Specifications service loop and be securely fastened by an approved method
  • Media type icon

    18-CD19D5-35-EN_02012019

    Document Title:Installer's Guide - Upflow/Horizontal and Downflow/Horizontal Gas-Fired Condensing Furnaces Models: TUC1, AUC1, TDC1, ADC1
    Publication Type:Installation
    Publication Date:2019-02-01
    -EN © 2019 Trane All Rights Reserved 18-CD19D5-35-EN Installer’s GuideSAFETY SECTION The following safety practices and precautions must be followed during the installation, servicing, and opera-tion of this furnace. 1. Use only with the type of gas approved for this fur- nace. Refer to the furnace
  • Media type icon

    CLCH-SVX010E-EN_08152024

    Performance Climate Changer™ Air HandlerModel TCFS and TCPACustom Air Handlers for Any Application Installation, Operation, and Maintenance August 2024 CLCH-SVX010E-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of
  • Media type icon

    2311-4274E_06272023

    Document Title:Horizontal Unit Vent
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-06-27
    Text 4 AutoCAD SHX Text 2 AutoCAD SHX Text COM AutoCAD SHX Text CSP AutoCAD SHX Text FAN SW AutoCAD SHX Text ZONE AutoCAD SHX Text 24V GND AutoCAD SHX Text 24V AC AutoCAD SHX Text ZONE TEMP AutoCAD SHX Text SETPOINT AutoCAD SHX Text SENSOR GND AutoCAD SHX Text J1-5 AutoCAD SHX Text J1-7 AutoCAD SHX
  • Media type icon

    18-HD72D1-11F-EN_02232024

    1-Stage Thermostat/AC with a 2-Stage Furnace, add jumper connection between W1 and W2 to enable full furnace heating capacity. NOTES: Note 3 Note 11 Note 7 Note 2 Note 7 Note 3 Note 3 Note 8 Note 10 Note 8 & 9 Note 6 Trane thermostats XL824. 824 Programmable Wi-Fi Comfort Control 18-HD72D1-11F-EN