Search Results: TEMP-PRC012A-EN

Showing 631 - 640 of 7,133 results

Display results per page.
  • Media type icon

    12132845B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 60KW - 208V/240V, 120KW & 150KW - 480V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    4723QB4 MANUAL DISCONNECT - ELEC HEAT 4283S10 HIGH TEMP LIMIT - MANUAL RESET 4663S11 HIGH TEMP LIMIT - AUTO RESET #1 4653S12 HIGH TEMP LIMIT - AUTO RESET #2 4653S13 HIGH TEMP LIMIT - AUTO RESET #3 4653XD5 TERMINAL BLOCK 4283XD5 TERMINAL BLOCK 4253XD16 TERM BLOCK - 115 VAC 4653XD17 TERM BLOC - 115 VAC
  • Media type icon

    BAS-SVX077U-EN_03312026

    Document Title:Tracer® SC+ System Controller with the Tracer® Synchrony User Interface
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-03-31
    Limit Setpoint Default AV Appendix C: Key Mapping and Enumerations for Unit Controllers BAS-SVX077U-EN 181 Table 22. Tracer UC400/Symbio 500 unit controller points: VAVAHU applications (continued) UC400/Symbio 500 point name UC400/Symbio500 point type Description Space Temp Setpoint Default AV Space
  • Media type icon

    18-CD30D1-20-EN_06162020

    Document Title:Installer's Guide Upflow/Horizontal and Downflow/ Horizontal, Gas-Fired, Direct Vent, Variable Speed Inducer, Modulating, Condensing, Communicating Furnaces *UHM and *DHM Models (*First letter may be A or T)
    Publication Type:Installation
    Publication Date:2020-06-16
    fully Communicating or 24 VAC modes, the furnace can support single or multi-stage heat pump, AC, or heating only applications. Combined with a communicating Comfort Control only, the furnace will support a single stage 24 VAC cooling outdoor unit only. 18-CD30D1-20-EN 18-CD30D1-20-EN Installer’s
  • Media type icon

    12132847B_12042024

    Document Title:SCHEMATIC - ELECTRIC HEAT WITH SCR MODULATING - 90KW - 208V/240V, 190KW - 480V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-04
    CONTACTOR - BACK-UP 4373QA32 CONTACTOR - BACK-UP 4693QA33 CONTACTOR - BACK-UP 4403QA33 CONTACTOR - BACK-UP 4703QA34 CONTACTOR - BACK-UP 4443QA34 CONTACTOR - BACK-UP 4723QA35 CONTACTOR - BACK-UP 4733QA35 CONTACTOR - BACK-UP 4473QB4 MANUAL DISCONNECT - ELEC HEAT 4273S10 HIGH TEMP LIMIT - MANUAL RESET
  • Media type icon

    16027700002075_07172020

    -PR O-A GAS- A RED P-MHI C GAS VAL GRAY BLAC K XP1XS1 XS2 XP2 XS3XP3 XS4XP4 IND XS5XP5 XS6XP6 Compressor Outdoor fan RT1 XS1-XS8 FAN_IN COMP A,COMP B RT2-A,RT2-B FAN_OUT A,FAN_OUT B Indoor fan Indoor room temp. sensor Connector High pressure switch High discharge temperature switch CODE TITLE XP1-XP8
  • Media type icon

    IAQR-SVX002B-EN_07092025

    Document Title:Dehumidifier – 5DHUM098/5DHUM120
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-07-09
    , adjusted or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. July 2025 IAQR-SVX002B-EN Dehumidifier – 5DHUM098/5DHUM120
  • Media type icon

    UH-SVX002B-EN_08112020

    Document Title:Convertible Venting Type Gas-fired Tubular Propeller Style Unit Heaters Model GN
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-08-11
    Convertible Venting Type Gas-fired Tubular Propeller Style Unit Heaters Model GN Installation, Operation and Maintenance August 2020 UH-SVX002B-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating
  • Media type icon

    DL-SVN003A-XX_11012018

    Document Title:Split-System Heat Pump
    Publication Type:Installation
    Publication Date:2018-11-01
    ceiling opening can be regulated within the range shown in following diagram; so center the main unit against the opening of ceiling, en-suring that the respective opposite sides on all sides of the clearance between them becomes identical. • Use M10 (3/8") suspension bolts.* Suspension bolts are to be
  • Media type icon

    SS-SVX11N-EN_06182022

    KOH/g if aburnout occurred. Start-Up SS-SVX11N-EN 111 Figure 74. System charging chart (all units) 250 300 350 400 450 500 550 600 650 700 70 80 90 100 110 120 130 140 150 Dis char ge Pres sure , psi g Liquid Line Temp at Outdoor Unit, °F RemoveCharge Add Charge 150’ lines150" lines Add Charge 50
  • Media type icon

    CG-PRC021-EN_02152011

    Document Title:Made in China 60 Hz - Product Catalog - Air-Cooled Scroll Chillers Model CGAM 20-130 Nominal Tons
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2011-02-15
    Air-Cooled Scroll Chillers Model CGAM 20-130 Nominal Tons60 Hertz Version February 2011 CG-PRC021-EN Product Catalog © 2011 Trane All rights reserved CG-PRC021-EN Introduction Design and manufacturing excellence makes Trane a leader in the air-cooled chiller market place. This tradition of using