Search Results: 2024

Showing 531 - 540 of 1,032 results

Display results per page.
  • Media type icon

    ACC-SVN226D-EN_09152024

    Document Title:Roof Curb Precedent™ Packaged Rooftop Units 12.5 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    September 2024 ACC-SVN226D-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    OAU-SLB006B-EN_02012024

    Document Title:Trane® Horizon® Outdoor Air Units - Dedicated Outdoor Air Solutions Water-Source Heat Pumps Air-Source Heat Pumps
    Publication Type:Sales Brochure
    Publication Date:2024-02-01
    . Peerless Performance Horizon DOAS Units are often paired with Axiom WSHP systems in multi-tenant buildings to provide fresh supply air for comfort system zones. Comfort Zone OAU-SLB006B-EN02/01/2024 Learn More at Trane.com/doas © Trane. All Rights Reserved. Trane – by Trane Technologies (NYSE: TT), a
  • Media type icon

    12134918_A_04052024

    Document Title:DIAGRAM; SCHEMATIC/COMPONENT LOCATION - ELECTRIC HEAT-36KW - 460V/575V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-04-05
    RIGHT SIDE OF THE SCHEMATIC DESIGNATE THE LOCATION OF CONTACTS BY THE LINE NUMBER. AN UNDERLINED NUMBER INDICATES A NORMALLY CLOSED CONTACT. AN OPEN ARROW BELOW THE LINE NUMBER POINTING UPWARD INDICATES A TIMED CONTACT WHICH BEGINS TIMING WHEN ENERGIZED. SEE UNIT NAMEPLATE FOR LINE VOLTAGE AND MAX. FUSE SIZE SEE UNIT NAMEPLATE FOR LINE VOLTAGE AND MAX. FUSE SIZE RELEASED 05/Apr/2024 11:51:40 GMT Sheet 1
  • Media type icon

    1213-4835B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, MOD GAS HEAT, 230V, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    PPM 116SHEET 3LINE 123BL RBK 1 230V208VCOM COM 115V XFMR2 PPF91 123 PPM91 123 1 2 TO HTB1SHEET 1LINE 42 2 123456789 123456789 10111213141516 1234 123456 1234 PPM14712 PPF511234 PPM511234 PPF1511234 PPF611234 PPM611234 PPF1611234 1234 123 1234 123 MODBUS-IDM1123 MODBUS-IDM2123 123 123 MODBUS-1E123 MODBUS-1F123 123 MODBUS-1C123 MODBUS-1A123 123 MODBUS-1123 123 RELEASED 12/Sep/2024 12:59:54 GMT Sheet 1
  • Media type icon

    1213-4305D_07312024

    Document Title:SCHEMATIC/COMPONENT LOCATION - ELECTRIC HEAT - 27 & 36 KW 460V/ 575V
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-07-31
    . THERMOSTAT DEVICES ARE EQUIPPED WITH AUTO-RESETTING THERMALLIMIT SWITCHES AND ONE-SHOT LIMIT FUSE. WIRES 134A, 135A, 136A, PRESENT ON UNITS WITH OPTIONALDISCONNECT/CIRCUIT BREAKER. 4. IF ANY OF THE ORIGINAL WIRING AS SUPPLIED WITH THE UNIT MUST BE REPLACED, USE ONLY APPLIANCE WIRING MATERIAL RATED AT 105° C OR EQUIVALENT. SEE UNIT NAMEPLATE FOR LINEVOLTAGE AND MAX. FUSE SIZE RELEASED 31/Jul/2024 14:23:08 GMT Sheet 1
  • Media type icon

    1213-4848B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, EFLEX, MOD GAS HEAT, 460V/575V, STD SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    10111213141516 1234 123456 1234 1234 123 1234 123 PPF511234 PPM511234 PPF611234 PPM611234 PPF1511234 PPF1611234 MODBUS-IDM1123 MODBUS-IDM2123 MODBUS-1E123 123 MODBUS-1F123 123 123 123 MODBUS-1C123 MODBUS-1A123 123 MODBUS-1123 RELEASED 12/Sep/2024 12:59:55 GMT Sheet 1
  • Media type icon

    12134934C_12032024

    Document Title:IPAK 1 COMPONENT LAYOUT 90-130T UNIT DEVICE LOCATIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-12-03
    SEE SHEET 14 FOR MAIN CONTROL BOX LAYOUT SEE SHEET 16 FOR VFD PANEL LAYOUTS SEE SHEET 17 FOR HEAT SECTION LAYOUTS 2M6 AND 2M9 ARE THE LOW AMBIENT CONTROLLED CONDENSER FAN MOTORS MAIN CONTROL BOX 2M6 1 2 1 1 2 3 4 5 6 4 3 5 6 RELEASED 03/Dec/2024 18:07:47 GMT Sheet 1
  • Media type icon

    ENGY-SLB051-EN_03102021

    Document Title:Sample Electricity Client Pricing Summary
    Publication Type:Sales Brochure
    Publication Date:2021-03-10
    : $0.00376 Supplier Product(s)“12-Months Jan 2021 - Jan 2022” “24-Months Jan 2021 - Jan 2023” “36-Months Jan 2021 - Jan 2024”Comments Supplier A All-Inclusive Fixed Price, No Pass-Throughs: $0.04221 $0.04029 $0.03928Credit: ApprovedPayment Days: Net 30 daysAdder Components: All-InTaxes: Not included in
  • Media type icon

    1213-4836B_09122024

    Document Title:SCHEMATIC; SHEET 2, POWER, DUAL INDOOR FAN, MOD GAS HEAT, 460V/575V, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-09-12
    MODBUS-1E123 MODBUS-IDM2123 MODBUS-1F123 123 PPF611234 PPM611234 PPF1611234 123 MODBUS-1C123 123 MODBUS-1A123 123 MODBUS-1123 RELEASED 12/Sep/2024 12:59:55 GMT Sheet 1
  • Media type icon

    ACC-SVN173F-EN_09152024

    Document Title:CO2 Sensing Kit Foundation™ Packaged Rooftop Units 3 to 5 & 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    CO2 Sensing KitFoundation™ Packaged Rooftop Units3 to 5 Tons15 to 25 Tons Installation Instructions September 2024 ACC-SVN173F-EN Model Numbers: Used With: BAYCO2K300*, ASYSTAT900* Foundation Wall Mounted SensorBAYCO2K301*, ASYSTAT901* Foundation Duct Mounted Sensor SAFETY WARNINGOnly qualified