    GMND-SVX01C-EN_07112020

    Document Title:Gas Unit Heater Separated Combustion Indoor Gas-Fired Duct Furnace
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-07-11
    . Dimensions, standard units GMND-SVX01C-EN 9 Unit Dimensions and Weights Table 2. Performance data Unit Size InputOutput FLA @ 115V MCA @ 115V MIN Temp. Rise P.D. MAX Temp. Rise P.D.MAX MIN MBh (kW) MBh (kW) MBh (kW) cfm (m3/s)Deg. F (Deg. C)in. of H2O (kPa) cfm (m3/s)Deg. F (Deg. C)in. of H2O (kPa
  • Media type icon

    22-1802-03_04012009

    Document Title:Trane Product Data Upflow/Horizontal 80 percent 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner XV80i Models
    Publication Type:Product Data
    Publication Date:2009-04-01
    frequent cleaning in homes with high indoor relative humidity (greater than 65% RH). Consult your service professional about cleaning intervals. 8PUB. NO. 22-1802-03 PerformanceData SW7 SW8 0.1 0.3 0.5 0.7 0.9 CFM 583 590 625 622 620 Temp. Rise 50 49 46 46 47 Watts 60 87 126 157 192 CFM 635 687 701 695
  • Media type icon

    GUNE-SVX001C-EN_05042022

    Document Title:Tubular Indoor Gas Fired Duct Furnace
    Publication Type:Installation Operation and Maintenance
    Publication Date:2022-05-04
    GUNE-SVX001A-EN (16 Jun 2014): Installation, Operation, and Maintenance - Tubular Indoor Gas-Fired Duct Furnace Tubular Indoor Gas Fired Duct Furnace Installation, Operation, and Maintenance May 2022 GUNE-SVX001C-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment
  • Media type icon

    WSHP-SVG004A-EN_12072025

    Document Title:Water Source Heat Pump Axiom™ Variable Speed – Compressor Inverter
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-12-07
    -SVG004A-EN Troubleshooting GuideWater Source Heat Pump Axiom™ Variable Speed — Compressor Inverter Model Number: VSHK024-060VSVK024-060 ©2025 WSHP-SVG004A-EN IntroductionRead this manual thoroughly before operating or servicingthis unit. Warnings, Cautions, and NoticesSafety advisories appear throughout
  • Media type icon

    RT-SVX094C-EN_10312025

    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 RT-SVX094C-EN Installation, Operation, and MaintenanceFoundation™ Packaged
  • Media type icon

    BAS-SVN039C-EN_06192020

    Document Title:Air-Fi® Wireless Communications Sensor (WCS-SB/R)
    Publication Type:Installation
    Publication Date:2020-06-19
    ConfigurationInstructions Air-Fi® Wireless CommunicationsSensor (WCS-SB/R) Model Number: X13791004001 June 2020 BAS-SVN039C-EN WARNINGIndicates a potentially hazardous situation which,if not avoided, could result in death or seriousinjury. CAUTIONIndicates a potentially hazardous situation which,if not avoided, could
  • Media type icon

    PKGP-SVX010C-EN_08192023

    Document Title:Packaged Rooftop Air Conditioners Precedent™ Heat Pump Standard Efficiency 12.5 to 25 Tons — 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2023-08-19
    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. August 2023 PKGP-SVX010C-EN Installation, Operation, and MaintenancePackaged Rooftop
  • Media type icon

    A951X-SVX001-1D-EN_06052024

    Document Title:RunTru/Ameristar Installation, Operation, and Maintenance - Upflow/Horizontal and Downflow Gas-Fired, Direct/Non-Direct Vent, Single Stage Condensing Furnaces with High Efficiency Motor A951X
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-06-05
    FLANGE, PIPE,COUPLING AND METAL PANELWITH HI TEMP RTV SILICONE SEALANT CLEARANCE - 0" ACCEPTABLE FOR PVC VENT PIPE 1" ACCEPTABLE FOR TYPE 29-4C STAINLESS STEEL VENT PIPE FFuurrnnaaccee GGeenneerraall IInnssttaallllaattiioonn 42 A951X-SVX001-1D-EN When penetrating roof with PVC vent pipe, a flexible
  • Media type icon

    SO-SVN033A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel Double Door Pneumatic
    Publication Type:Installation
    Publication Date:2023-10-13
    AFD starter nodule on sub plate w/o power supply or LV PTs Assembly for unit mount UCP2 non-communicating AFDH 018504340100 AFD starter nodule on sub plate with power supplyw/o LV PTs Assembly for remote mount UCP2 non-communicating AFDH 018504370100 6 SO-SVN033A-EN General Information Temp sensor Low
  • Media type icon

    CVHE-CLD-1A_02012000

    Document Title:Refrigeration. Water-Cooled, Hermetic CenTraVac, Clear Language Display for UCP2 Control Panels. Models CVHE, CVHF and CVHG 50 and 60 Hz See CVRB-SUPL-1 5/1/96 for more information.
    Publication Type:Installation Operation and Maintenance
    Publication Date:2000-02-01
    ...................................................... 10 Chiller Operating Mode ..................................... 10Chiller Operating Mode ..................................... 12Active Chilled Water Setpoint/Evap LeavingWater Temp ..................................................... 12 Active Chilled Water Setpoint/Chilled