Search Results: TEMP-PRC013A-EN

Showing 471 - 480 of 7,116 results

Display results per page.
  • Media type icon

    1213-2587C_10072018

    AIR TEMP4M12 SUPPLY FAN MOTOR #14M13 SUPPLY FAN MOTOR #25BT4 SENSOR - CKT #1 EVAP SUCTION TEMP #15BT5 SENSOR - CKT #1 EVAP SUCTION TEMP #25BT6 SENSOR - CKT #2 EVAP SUCTION TEMP #15BT7 SENSOR - CKT #2 EVAP SUCTION TEMP #25BT8 SENSOR - MIXED AIR TEMPERATURE5BT9 SENSOR - LEAVING EVAP AIR TEMP COIL #1
  • Media type icon

    BAS-SVN212C-EN_11242021

    Document Title:Symbio 210 Programmable VAV Controller
    Publication Type:Installation
    Publication Date:2021-11-24
    Symbio 210 Programmable Controller Installation, Operation, and Maintenance manual (BAS-SVX084-EN). Storage and Operating Specifications Storage Temperature: -67°F to 203°F (-55°C to 95°C) Humidity: 5% to 95% (non-condensing) Operating Temperature: -40°F to 122°F (-40°C to 50°C) Humidity: 5% to 95
  • Media type icon

    WSHP-PRC040B-EN_01122026

    Water Source Heat Pump Axiom™ Water-to-Water – EXW January 2026 WSHP-PRC040B-EN Product CatalogWater Source Heat PumpAxiom™Water-to-Water – EXW5 to 20 Tons – 60 Hz ©2026 Trane WSHP-PRC040B-EN IntroductionSimilar to a small reverse cycle chiller, a water-to-water heat pump contains a source-side
  • Media type icon

    SO-SVN032A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel Single Door Pneumatic
    Publication Type:Installation
    Publication Date:2023-10-13
    UCP2 non-communicating AFDH 018504370100 6 SO-SVN032A-EN General Information Temp sensor Low range temperature sensor SEN02133 Triac Dual triac output BRD04876 TWTI Triple winding temperature input MOD02462 Symbio™ controller MOD02979 WIFI WiFi Mobile App MOD03122 Air-Fi® Air-Fi® BACnet® via Zigbee®
  • Media type icon

    BAS-SVX083D-EN_04222021

    Document Title:Enercept FLEX Compact Power and Energy Meter Uni-directional, Bi-directional for BACnet/Modbus
    Publication Type:Installation
    Publication Date:2021-04-22
    (I/O communications, CT): 24 AWG to 16 AWG (0.2...1.5 mm2)Optional Bracket, Rail Mounted: T35 (35 mm) DIN Rail per EN50022Optional Bracket, Rail Mounted: #10 or MS screws, 2.953 in (75 mm), center-to-center Operating Conditions: Operating Temp: -30°C to 70°C (-22°F to 158°F) [Limited to 131°F (55
  • Media type icon

    22-1871-09-EN_06092020

    Product Data Split System (R-410A)Multi-Zone, Inverter System 18,000 to 42,000 BTU/Hr 22-1871-09-EN Multi-Zone Outdoor UnitHeat Pump 4TXM6518A1 4TXM6524A1 4TXM6530A1 4TXM6536A1 4TXM6542A1 4TXM6518A1020 4TXM6536A1040, , 4TXM6524A1030, 4TXM6530A1040 4TXM6542A1050 2 It's Hard to Stop a Trane
  • Media type icon

    OAU-SVX008B-EN_03092025

    OAU-SVX008-EN.book Horizon™ Outdoor Air UnitHorizon R-454B Refrigerant with v12 Controls Installation, Operation, and Maintenance March 2025 OAU-SVX008B-EN Models: OABD, OABE, OABF, OADG, OAND, OANE, OANF, OANGImportant: Proper completion of the tasks outlined in this Installation, Operation, and
  • Media type icon

    RT-SVX23R-EN_09222022

    and 2. 5. Connect the sensor (OAS) using two wire nuts to the two (2) field supplied wires that were connected to terminals 1 and 2 on J6. 62 RT-SVX23R-EN Troubleshooting Table 21. Fault detection and diagnostic codes Failures Primary Fault Codes Information Code Mixed Air Temp Sensor Fail Outdoor
  • Media type icon

    RT-SVX39C-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ — Heat Pump 5 – 10 Tons – 50 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    Temp Sensor 9 Flashes: RAM Fault 10 Flashes: ROM Fault 11 Flashes: EEPROM F 40 RT-SVX39C-EN RT-SVX39C-EN 41 Wiring Diagrams Note: Wiring diagrams can be accessed using e-Library by entering the diagram number in the literature order number search field or by contacting technical support. Table 10
  • Media type icon

    12135011B_06132024

    AIR TEMP4M12 SUPPLY FAN MOTOR #14M13 SUPPLY FAN MOTOR #25BT4 SENSOR - CKT #1 EVAP SUCTION TEMP #15BT5 SENSOR - CKT #1 EVAP SUCTION TEMP #25BT6 SENSOR - CKT #2 EVAP SUCTION TEMP #15BT7 SENSOR - CKT #2 EVAP SUCTION TEMP #25BT8 SENSOR - MIXED AIR TEMPERATURE5BT9 SENSOR - LEAVING EVAP AIR TEMP COIL #1