Search Results: 2023

Showing 391 - 400 of 965 results

Display results per page.
  • Media type icon

    1213-4798B_06132024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, WSHP, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    DATE:REVISED BY:APPROVED BY:CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV YASHRAJ.N.MD. MACVICAR 17-NOV-2023- - 17-MAY-2024A. WAELDE D. MACVICARCREO SCHEMATICS 12134798 B1 PRECEDENTUNIT SCHEMATIC; SHEET 1POWER, SINGLE COMPRESSOR, WSHP, HIGH SCCR TRANE ® 1A 1A(BR) 2A 2A(O) (O) 3A(Y) 3A AUX-C
  • Media type icon

    1213-4797B_06132024

    Document Title:SCHEMATIC; SHEET 1, POWER, SINGLE COMPRESSOR, SINGLE CONDENSER FAN, HIGH SCCR
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-06-13
    TO OUTSIDE PARTIES WITHOUT THEWRITTEN CONSENT OF TRANE. DESIGNER:ENGINEER:TRANE © DATE:REPLACES: SIMILAR TO: REVISION DATE:REVISED BY:APPROVED BY:CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV YASHRAJ.N.MD. MACVICAR 21-NOV-2023- - 16-MAY-2024A. WAELDE D. MACVICARCREO SCHEMATICS 12134797
  • Media type icon

    12134653_B_02202023

    Document Title:IPAK 2 CONTROLS SCHEMATIC 90-150T 90-150T VARIABLE SPEED REFRIGERATION SYSTEM #1
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    120SHEET 21XD21-1 LINE 57SHEET 1 1XJ18 LINE 252SHEET 5 1TA2 LINE 226SHEET 4 1KF1 LINE 116SHEET 21XD22-1 LINE 424SHEET 8 1KF5 RELEASED 20/Feb/2023 20:02:27 GMT Sheet 1
  • Media type icon

    12134683_B_02202023

    Document Title:COMPONENT LAYOUT; 90-150T UNIT DEVICE LOCATIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-02-20
    SECTIONRETURN SECTION JUNCTIONBOX JUNCTIONBOXBOX HEAT JUNCTIONHEAT CONTROL BOXSUPPLY & COMPRESSORVFD PANELS RETURN/RELIEFVFD & RETURNCONTROL BOX FRESH AIR SECTION WITH ENERGY RECOVERY WHEEL CONTROL BOX NOTES:ALL DEVICES SHOWN, SEE SCHEMATICFOR OPTIONAL DEVICES USAGE. RELEASED 20/Feb/2023 20:04:00 GMT Sheet 1
  • Media type icon

    12134899_C_04172024

    Document Title:IPAK 2 CONTROLS SCHEMATIC 90-150T UNIT CONTROLS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-04-17
    USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV T. PEEDJ. PLUMMER 11/1/2023 04/10/2024 A. WAELDE J. PLUMMERCREO SCHEMATICS 12134899 COF4 17 IPAK 2CONTROLS SCHEMATIC 90-150TUNIT CONTROLS TRANE ® 1KF1UNIT CONTROLS MODULE 1 2 3 4 1 2 - + - + +- +- +24VDC +-VDC+24 USBSERVICE PORT (UCM) BACNET/MODBUS
  • Media type icon

    12134935_B_02282024

    Document Title:IPAK 2 COMPONENT LAYOUT 90-150T UNIT DEVICE LOCATIONS
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-02-28
    DEVICE LOCATIONS T.PEEDJ. PLUMMER 11/30/2023 CREO SCHEMATICS 12134935 BOF15 19 IPAK 2TRANE ® 2M1 2M2 2M3 2M27 2M5 2M4 4M12 6M14 6M27 2M112C 2M9 2M10 2M8 2M7 2M6 2M24 2M11 2M10 2M9 2M21 2E12 2S23 2KF42 2E11 2E5 2KF37 2E4 2KF36 2M8 2M6 2M7 2E8 2S22 2KF35 2E1 2E2 2KF28 2E3 2KF41 2QM18 2QM9 2QM7 2QM5 2S5
  • Media type icon

    12134864B_11212024

    Document Title:INTELLICORE RA SCHEMATIC 20-60T POWER
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-21
    MOTOR 1C 972M9 CONDENSER FAN MOTOR 2A 902M10 CONDENSER FAN MOTOR 2B 932M11 CONDENSER FAN MOTOR 2C 97 DESIGNER: ENGINEER: TRANE © DATE: REPLACES: SIMILAR TO: REVISION DATE: REVISED BY: APPROVED BY: CAD SYSTEM USED: MASTER NUMBER: DRAWING NUMBER: SHEET: REV C.SCHOTT S. MCKINLEY 25-SEP-2023 14-AUG-2024
  • Media type icon

    23116153_A_03272023

    Document Title:WSHP Schematic Diagram GE/EX/DX UC400-B E-Heat Ready ECM - Single Phase
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    SECTION4 WATER COIL SECTION5 RETURN AND FRESH AIR SECTION6 FIELD INSTALLED DEVICE 1234 1234567891011121314 123456 123456 123 12 12 123 123 12 12 123456 12345 PP 1232 4 J2C-1J2C-2 J2L-1J2L-2 1234 12 2 4 12 123456 123456 1234 1 2 3 4 1234 1 2 3 4 1234 12 1TB2-11TB2-2 TO DUCT HEATERRUN INPUT 24VAC 70C CCHR 1K1 1SR 1S5 3S2 2B1S1 2B1S2 1K4 3S3 T1 T2 T3 L1 L2 L3 1S4 RELEASED 27/Mar/2023 21:57:28 GMT Sheet 1
  • Media type icon

    23116154_A_03272023

    Document Title:WSHP Schematic Diagram GE/EX/DX UC400-B E-Heat Ready ECM - Three Phase
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    123456 123456 123 12 12 123 123 12 12 123456 12345 PP 1232 4 J2C-1J2C-2 J2L-1J2L-2 1234 12 2 4 12 123456 123456 1234 1 2 3 4 1234 1 2 3 4 1234 12 4P-G4P-L4P-N GND J6B-3J6B-6 4P-C5P-1 J6B-1 J6B-4 1TB2-2 1TB2-1 70C TO DUCT HEATERRUN INPUT 24VAC 1K1 T1 T1 L3 L1 L2 T3 1S4 1S5 1SR 1K4 3S3 2B1S1 2B1S2 3S2 RELEASED 27/Mar/2023 21:57:29 GMT Sheet 1
  • Media type icon

    23116088_C_03272023

    Document Title:WSHP SCHEMATIC DIAGRAM DXV/DXH DELUXE CONTROL - HP W/ HGR ECM - SINGLE PHASE
    Publication Type:Wiring Diagram or Manual
    Publication Date:2023-03-27
    TRANE CO. 3. NUMBERS ALONG THE RIGHT SIDE OF THE SCHEMATIC DESIGNATE THE LOCATION OF CONTACTS BY THE LINE NUMBER. AN UNDERLINED NUMBER INDICATES A NORMALLY CLOSED CONTACT. AN OPEN ARROW BELOW THE LINE NUMBER POINTING UPWARD INDICATES A TIMED CONTACT WHICH BEGINS TIMING WHEN ENERGIZED. RELEASED 27/Mar/2023 21:57:29 GMT Sheet 1