Search Results: RT- SVX079*-EN*

Showing 381 - 390 of 419 results

Display results per page.
  • Media type icon

    18-EB39D1-1D-EN_01182024

    Document Title:Installation and Operations Manual - Single Packaged Cooling/Electric Heat, 13.4 SEER2 Convertible, 2 – 5 Ton, 4TCC4*E
    Publication Type:Installation
    Publication Date:2024-01-19
  • Media type icon

    12-1144-03_04012003

    Document Title:16 SEER PACKAGE GAS / ELECTRIC TWO STAGE CONVERTIBLE MODELS YCZ036,050,060F1/3/4 3, 4, 5 TON
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2003-04-01
  • Media type icon

    PKG-PRC001-EN_04012004

    Document Title:Diamond Self Contained -Central Self-Contained Air Conditioner 20 to 40 TR - Air or Water Remote Condenser CRCE/CRCB 60Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2004-04-01
    power inlet7 Refrigeration connections (single position) I (LENGHT WITH FINS)J (HE IGH T W ITH FIN S) MA CH INE FR ON TAL PA RT 26 PKG-PRC001-EN Dimensions CRCE Table 24 - Dimensions CRCE Dimension 050 075 100 125 150 A 922 1146 1420 1640 1640 B 1373 1474 1525 1600 1829 C 560 560 560 560 560 D 341
  • Media type icon

    SO-SVN048A-EN_10132023

    Document Title:AFDR Retrofit Air-cooled Adaptive Frequency Drive™ For Use with RTHD Chillers
    Publication Type:Installation
    Publication Date:2023-10-13
    . Component locations con dens er oil s ump s e p a r t o ra e p a r t oas r evap orat or com pres sor ga s p ump TR V RT HD Val ve L oca tio n 17 18 12 34 5 6 7 89 10 11 12 1314 1516 19 20 22 33 3435 31 38 EX Vve nt li ne o i l c o o l e r 24 25 26 2728 30 3640 41 42 43 4748 23 49 com po nen ts in
  • Media type icon

    YCY-IOM-1E_06212005

    Document Title:Single Package Gas/Electric 14 SEER Convertible 2 - 5 Ton
    Publication Type:Installation Operation and Maintenance
    Publication Date:2005-06-21
  • Media type icon

    SS-SVX014D-EN_03092025

    Document Title:Split System Air Conditioners Odyssey™ with Symbio™ Controls Cooling Condenser, R-454B 6 to 25 Tons
    Publication Type:Installation Operation and Maintenance
    Publication Date:2025-03-09
    regarding the propermicrochannel coil cleaning procedure, refer to RT-SVB83*-EN Due to the soft material and thin walls of the MCHE coils,the traditional field maintenance method recommended forRound Tube Plate Fin (RTPF) coils does not apply tomicrochannel coils. Moreover, chemical cleaners are a
  • Media type icon

    VAV-SVX08ABEN_12132024

    Document Title:VariTrane™ Variable Air Volume (VAV) Terminal Air Units - Shutoff, Fan Powered, and CoolSense™ Sensible Cooling
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-12-13
    = Electric HeatW = Hot Water Heat Digit 4 — Development Sequence F = Low Height Units Digit 5, 6 — Primary Air Valve 05 = 5" inlet (350 cfm)06 = 6" inlet (500 cfm)08 = 8" inlet (900 cfm)10 = 10" inlet (1400 cfm)RT = 8" × 14" inlet (1800 cfm) Digit 7, 8 — Secondary Air Valve Used 00 = N/A Digit 9 — Fan A
  • Media type icon

    YCX-IOM-2C_10012003

    Document Title:Single Package Gas Electric 12 SEER Convertible 2 - 5 Ton. YCX024G1L-M, YCX030G1L-M, YCX042G1,3-M, YCX048G1,3,4-H, YCX036G1,3-L-M, YCX036G1,3,4-H, YCX060G1,3,4-M. BAYLIFT002A LIFTING LUG KIT
    Publication Type:Installation Operation and Maintenance
    Publication Date:2003-10-01
  • Media type icon

    SO-SVN036B-EN_12132024

    Document Title:CVRF - Symbio™ 800 Chiller Controller Retrofit Replacement Panel UCP2
    Publication Type:Installation
    Publication Date:2024-12-13
    1K8 2 3 2 1 1X1-15 1X1-16 1F9 1F8 LT RT 1C1 34 1K8 Installation 32 SO-SVN036B-EN 120 Vac Refrigerant Pump Style Oil Pump Installation1. Remove start capacitor from oil pump motor junction box and discard. This will not be used in this application.2. Install new wire of same gauge as existing from
  • Media type icon

    SO-SVN035A-EN_10132023

    Document Title:CVRF - Symbio™ Chiller Controller Retrofit Replacement Panel UCP1
    Publication Type:Installation
    Publication Date:2023-10-13
    12C 1X1-14 21C 2M 23B 24B 123 124 23A 24A22A (6-1/4 A) (6-1/4 A) LTRT 1K8 2 3 2 1 1X1-15 1X1-16 1F9 1F8 LT RT 1C1 34 1K8 SO-SVN035A-EN 29 Installation Installation of Oil Pump MotorWiring and TerminalsThe CVRF installation will relocate the oil pump relay to the control panel. Follow the below steps