Search Results: TEMP-SLB008-EN

Showing 301 - 310 of 7,186 results

Display results per page.
  • Media type icon

    SS-PRC048C-EN_03142026

    Document Title:Split System Air Conditioners Odyssey™ with Symbio™ Controls Cooling Condenser, 6 to 25 Tons, 60Hz Air Handler, 5 to 25 Tons, 60Hz
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2026-03-14
    °F125°F CO MP RE SS OR HIG H S UC TIO N L IMIT ID C OIL FR OS T L IMIT Performance Data 46 SS-PRC048C-EN Table 30. Gross cooling capacities (MBh) 6 tons TTA072K*D condensing unit only (IP) Outdoor Temp(°F) Saturated Suction Temperature (°F)30 35 40 45 50 55 65Head Press (psig) 247.0 251.2 255.5 260.0
  • Media type icon

    PKGR-SVX003C-EN_10062025

    Document Title:Single Packaged Heat Pump, Choice, Convertible, 2 - 5 Ton, R-454B, 5WCC4
    Publication Type:Installation
    Publication Date:2025-10-06
    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. October 2025 PKGR-SVX003C-EN Single Packaged Heat PumpChoice, Convertible, 2 to 5 Ton, R
  • Media type icon

    BAS-SVP043B-EN_11242021

    Document Title:Symbio® 210 Programmable Controller For Variable-Air-Volume (VAV) Boxes / Integration Guide
    Publication Type:Integration Guide
    Publication Date:2021-06-15
    BAS-SVP043-EN.book Symbio® 210 Programmable ControllerFor Variable-Air-Volume (VAV) Boxes Integration Guide June 2021 BAS-SVP043A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air
  • Media type icon

    OAU-SVX006E-EN_06182021

    ) -  90 OAU-SVX006E-EN Startup Form Refrigeration Startup Test Procedures Important: Cooling startup can only be completed if the OA temp is >65°f or <105°F. Heating startup can only be completed if OA temp is <90°F 1. Test each circuit independently. 2. Tandem or trio circuits must have all
  • Media type icon

    1213-1533B_11082016

    Document Title:Foundation Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2016-11-08
    BLOCK - ELECTRIC HEAT 4,7 HTRA HEATER 15 HTRB HEATER 19 TCO1 TEMP CUTOUT 17 TCO2 TEMP CUTOUT 18 AVERTISSEMENT ADVERTENCIATENSION DANGEREUSE! COUPER TOUTES LES TENSIONS ETOUVRIR LES SECTIONNEURS À DISTANCE,PUIS SUIVRE LES PROCÉDURES DEVERROUILLAGE ET DES ÉTIQUETTES AVANTTOUTE INTERVENTION. VÉRIFIER
  • Media type icon

    EDU-SLB071-EN_04222026

    Document Title:Trane® Applied Heating Solutions - Sustainability has a warm side
    Publication Type:Sales Brochure
    Publication Date:2026-04-22
    APPLICATION COMPRESSOR TYPE TONS AND MBH REFRIGERANT MAX HOT WATER TEMP MAX LIFT Heat pump Heat recovery Centrifugal 275-500 tons; 2,100-4,900 MBH R-513A 130°F (54°C) ~80°F (29°C) Water-Sourced Agility® Model HDWA Heat pump 6-pipe Heat recovery Centrifugal 4-pipe or 6-pipe: 2,000-6,000 tons; 24,000
  • Media type icon

    SRV-SLB238-EN_07132020

    Document Title:Thermal Energy Storage / Infographic
    Publication Type:Sales Brochure
    Publication Date:2020-07-13
    SRV-SLB238-EN THERMAL ENERGY ANDOUT OF THATALMOST HALF40% of the world’senergy 1 due to HVAC 1 by 20402 forecasted to grow by power transformers are over 25 years old.4 72have already, or are now set to 3 Sources: 1 EIA / 2 3 4 Energy Department, 2014 13%70% “The value of Thermal Energy Storage
  • Media type icon

    BAS-SVX071C-EN_04222021

    Document Title:E50 Series Compact Power and Energy Meter BACnet MS/TP E50H2A-T2 for use only with E683 Series Rope CTs PN: X13690276001
    Publication Type:Installation Operation and Maintenance
    Publication Date:2021-04-22
    BAS-SVX071C-EN SSAAFFEETTYY WWAARRNNIINNGGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioningequipment can be hazardous and requires specific knowledge and training. Improperly installed
  • Media type icon

    ODR-SVN003D-EN_04182026

    Document Title:Multi-Speed Heat Pumps and Air Conditioners with WeatherGuard™ featuring ComfortSeek™
    Publication Type:Installation
    Publication Date:2026-04-18
    or altered equipment by an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. April 2026 ODR-SVN003D-EN Multi-Speed Heat Pumps and Air
  • Media type icon

    ACC-SVN310A-EN_09152024

    Document Title:Comparative Enthalpy Kit Foundation™ Packaged Rooftop Units 15 to 25 Tons
    Publication Type:Installation
    Publication Date:2024-09-15
    September 2024 ACC-SVN310A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning equipment can be hazardous and requires specific knowledge and training. Improperly installed