    TEMP-PRC006B-EN_10312025

    October 2025 TEMP-PRC006B-EN Product CatalogTrane Rental ServicesPackaged DX Air Conditioning — 575V ©2025 Trane TEMP-PRC006B-EN CopyrightThis document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part withoutwritten permission. Trane
  • Media type icon

    BAS-PTS032A-EN_12062024

    Symbio™ 800 Integration Points ListBACnet®RTAC (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Naming ConventionsThe communicated points for the Symbio™ controllers are generally named according to their function. While many of the points are read-only, others include both read and
  • Media type icon

    TEMP-PRC001C-EN_12132024

    Trane Rental ServicesPackaged DX Air Conditioning December 2024 TEMP-PRC001C-EN Product Catalog Introduction Warnings, Cautions, and NoticesSafety advisories appear throughout this manual as required. Your personal safety and the proper operation of this machine depend upon the strict observance of
  • Media type icon

    BAS-PTS008A-EN_11152024

    Symbio™ 800 Integration Points List LonTalk®Agility™ Water-cooled Chillers Date: 11/15/2024 Reference Document: BAS-SVP084*-EN Profile Definition and Network Variables The following tables are sorted as follows: • Tables are listed by unit/profile type and sorted by network variable number
  • Media type icon

    BAS-PTS026A-EN_12062024

    Inputs 3 Symbio™ 800 Integration Points ListBACnet®ACSA (UC800) Date: 12/6/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Description Units Configuration Dependency 51 Starts Cprsr2A Real52 Run Time Cprsr2A Real69 Heat Recovery Entering Water Temp Real70 Heat Recovery Leaving
  • Media type icon

    22-1673-10A-EN_05182020

    Document Title:Trane Downflow/Horizontal Right or Downflow/Horizontal Left 2-Stage, Variable Speed Gas-Fired Furnace XV 80 Two-Stage Fan Assisted Combustion System
    Publication Type:Product Data
    Publication Date:2020-06-10
    TEMP. RISEWATTS 134544 330 133544 380 132045 425 131045 475 127546 505 922-1673-10A-EN Performance Data *DD2C100A9V5VA FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTEROUTDOORUNIT SIZE (TONS)AIRFLOWSETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE S3-1 S3-2 S3-3
  • Media type icon

    TEMP-SVX003B-EN_05092025

    TEMP-SVX003-EN.book Trane Rental ServicesCooling Towers Installation, Operation, and Maintenance May 2025 TEMP-SVX003B-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air-conditioning
  • Media type icon

    BAS-PTS025A-EN_12062024

    Diagnostics 10 Symbio™ 800 Integration Points ListBACnet®ACRB Small (UC800) Date: 12/06/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Object States 11031 Diagnostic: Evap Rfgt Pool Temp Sensor Error - Ckt1 0= Normal1= In Alarm 11032 Diagnostic: Evap Rfgt Pool Temp Sensor Error - Ckt2 0
  • Media type icon

    TEMP-SVN003A-EN_07102021

    Document Title:Trane Rental Service Start-Up and Shutdown - RSGP0450F3 Generator
    Publication Type:Installation
    Publication Date:2021-07-10
    TEMP-SVN003-EN.book Trane Rental ServiceStart-Up and Shutdown - RSGP0450F3Generator Installation Instructions July 2021 TEMP-SVN003A-EN SAFETY WARNINGOnly qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventilating, and air
  • Media type icon

    BAS-PTS015A-EN_11152024

    the Water Temp in the Heat Recovery Tank Temperature Heat Recovery BAS-PTS015A-ENAnalog Inputs 4 Symbio™ 800 Integration Points ListBACnet®Series R® Model RTHD Date:11/15/2024Reference Document: BAS-SVP083*-EN Object Identifier Object Name Description Units Configuration DependencyAI- 10156 Heat