Search Results: DC-SLB007-EN

Showing 281 - 290 of 7,151 results

Display results per page.
  • Media type icon

    RT-SVX093E-EN_05152026

    Document Title:Precedent™ Packaged Rooftop
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-05-15
    Multi conductorWire)Before installing any connecting wiring between the unitand components utilizing a DC analog input\output signal,refer to the Dimensions and Weights chapter for theelectrical access locations provided on the unit. Installation RT-SVX093E-EN 59 • Table 22, p. 59 lists the conductor
  • Media type icon

    FNR-SVX004A-EN_05082026

    Document Title:RunTru/Ameristar Installation, Operation, and Maintenance - Upflow/Horizontal and Downflow Gas-Fired, Direct/Non-Direct Vent, Single Stage Condensing Furnaces with High Efficiency Motor A951X
    Publication Type:Installation Operation and Maintenance
    Publication Date:2026-05-08
    labels that are attached to the equipment. May 2026 FNR-SVX004A-EN Upflow/Horizontal and Dedicated DownflowGas-Fired, Direct/Non-Direct Vent, Single Stage CondensingFurnaces with High Efficiency Motor Upflow, Convertible toHorizontal Right or
  • Media type icon

    18-HD55D1-1C-EN_12172020

    Document Title:Trane XR103 Non-Programmable Heat Pump Thermostat TCONT103 Installation and User Guide
    Publication Type:Installation
    Publication Date:2020-12-17
    Pub No. 18-HD55D1-1C-EN Part No. 37-7790003 September 2020 TCONT103 Installation and User Guide Trane XR103 Non-Programmable Heat Pump Thermostat ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with
  • Media type icon

    S8XB-SVX001-1D-EN_08092024

    Document Title:Installation, Operation, and Maintenance Upflow/Downflow/Horizontal Gas-Fired, 1-Stage and 2-Stage Induced Draft Furnaces with High Efficiency Motor S8B1, S8X1, S8X2 - Q Models
    Publication Type:Installation Operation and Maintenance
    Publication Date:2024-08-09
    ground? Turn Comfort Control to “OFF” posi!on Correct wiring Check opera!onYES Replace IFC NO 7.1 Fault Code TTrroouubblleesshhoooottiinngg S8XB-SVX001-1D-EN 75 DEFINITION:The flame sense current is less than 0.5 micro-amp DC Once flame has been established, set meter to DC volts and measure across
  • Media type icon

    OAU-SVX007C-EN_11082023

    Recommended Wire Size 000–460 feet000–140 m 18 gauge0.75 mm2 461–732 feet104–223 m 16 gauge1 mm2 92 OAU-SVX007C-EN Installation Controls Using DC Analog Input/Output (Standard Low Voltage Multiconductor Wire) Before installing any connecting wiring between the unit and components utilizing a DC analog input
  • Media type icon

    TF-SVX005A-EN_06152025

    an unqualified person could result in death orserious injury. When working on the equipment, observe all precautions in the literature and on the tags, stickers, and labels that are attached to the equipment. June 2025 TF-SVX005A-EN Installation, Operation, and MaintenanceThermafit™ Modular Air
  • Media type icon

    ODR-SVX004D-EN_04172026

    -SVX004D-EN 25 Table 13. Defrost control thermistor (continued) Temp °F Temp °CThermistorResistance(ohms) Volts DC 115.00 46.11 4079 0.28 120.00 48.89 3665 0.26 125.00 51.67 3298 0.23 130.00 54.44 2972 0.21 135.00 57.22 2683 0.19Example: Sensor temp. = 19°F Measured Resistance = 46K ohmsThis sensor is good
  • Media type icon

    OAU-SVX01L-EN_06262023

    OAU-SVX01G-EN (11 Aug 2016): Installation, Operation, and Maintenance - Horizon Outdoor Air Unit - Indirect Gas-Fired/Electric Heat - Models: OADD, OADE, OAKD, OAKE, OAND, OANE Horizon™ Outdoor Air UnitIndirect Fired Gas/Electric Heat/Air Source Heat PumpModels: OAKD, OAKE/F, OAND, OANE/F
  • Media type icon

    18-HD54D1-1B-EN_12172020

    Document Title:Trane XR102 Non-Programmable Thermostat TCONT102 Installation and User Guide
    Publication Type:Installation
    Publication Date:2020-12-17
    Pub No. 18-HD54D1-1B-EN Part No. 37-7770002 SEPTEMBER 2020 Trane XR102 Non-Programmable Thermostat ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. These instructions do not cover all
  • Media type icon

    UN-SLB014-EN_05052023

    Document Title:CXAU VFD Unit
    Publication Type:Sales Brochure
    Publication Date:2023-05-05
    , parts and supply. For more information, please visit trane.com or tranetechnologies.com. © 2022 Trane. All Rights Reserved.All trademarks referenced in this document are the trademarks of their respective owners.UN-SLB014-EN July 2023 CXAU VFD Unit Air-Cooled Modular Chiller/Heat Pump 0-AquaCube 01