Search Results: ED*

Showing 271 - 280 of 1,420 results

Display results per page.
  • Media type icon

    RT-SVN07E-EN_06292020

    Document Title:Intellipak 2 Accessory Roof Curb Kit Rooftops, 90 - 162 Tons Air Handlers - Casings, A-C
    Publication Type:Installation
    Publication Date:2020-06-29
    time, and to make changes to its content without obligation to notify any person of such revision or change. © 2020 Trane RT-SVN07E-EN Introduction Trademarks All trademarks referenced in this document are the trademarks of their respective owners. Revision History Includes running edits to further
  • Media type icon

    PART-SVN116A-EN_06012009

    Document Title:Variable Frequency Drive Conversion to TR200 IntelliPak™ and Voyager™ III only
    Publication Type:Installation
    Publication Date:2009-06-01
    -supplied fasteners. Apply flexible extrusion trim to all edges of bracket that come into contact with electrical wires and cables. Route cable through back of mounting bracket and insert through hole where keypad is to mount. Attach cable connector to back of keypad connection point. Mount keypad
  • Media type icon

    RT-SVN17B-EN_04202020

    Document Title:Combustion Blower Motor Wiring Kit Gas Heat
    Publication Type:Installation
    Publication Date:2020-04-13
    T H -CLO GG ED F ILTE R S WIT CH O PTIO N C O M N ON C FFS 102A (RD ) 101A (PR) C O M N ON C CFS 100A (RD ) 58J( PR) 15 714 714 21 1211 12 13 13 13 13 19 18 18 & T CO1 5 WIR ING FRO M C CH2 Loca tion of th e ne w c ombu stio n bl ower mot or c onta ctor s RT-SVN17B-EN 7 ©2020 Trane and American
  • Media type icon

    RT-SVX45F-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ with eFlex™ Technology, Electric/Electric 3 to 10 Tons - 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    Ventilation) 6 RT-SVX45F-EN Model Number Descriptions Digit 27 - Unit Hardware Enhancements0 No Enhancements1 Stainless Steel Drain Pan Digit 31 - Advanced Unit Controls0 Standard Unit Controls1 Human Interface Model Number Notes 1. Standard on all eFlex™ and eDrive™ units. 2. Economizer with Barometric
  • Media type icon

    ACC-SVN02G-EN_04242020

    Document Title:Low Static Drive Kit 3 to 10 Ton Packaged Cooling Unit, 60 Hz 5 to 10 Ton Packaged Cooling Unit, 50 Hz
    Publication Type:Installation
    Publication Date:2020-04-24
    required RPM to produce the desired airflow. Refer to Table 1 and Table 2 for the sheave data. 7. Check the alignment between the fan and motor sheaves using a straight edge. Adjust as necessary. Torque the fan and motor sheave set screws to 126-165 inch pounds (14.2-18.6 N-m). 8. Torque the motor
  • Media type icon

    ACC-SVN11N-EN_06032020

    Document Title:Ventilation Override Kit Used with 3 to 10 Ton Packaged Units with ReliaTel™ Controls
    Publication Type:Installation
    Publication Date:2020-06-03
    edges or hot surfaces.3. Apply provided CO2 and ventilation override wiring diagram label next to the main unit wiring diagram label.4. Apply “BAYVNOR Kit Has Been Installed” label next to the main unit wiring diagram label.5. Make field wiring connections from customer’s fire panel or other control
  • Media type icon

    18-CH83D1-1B-EN_06032024

    Document Title:Installer's Guide - Concentric Vent Kit for Condensing Furnaces BAYAIR30CNVENT
    Publication Type:Installation
    Publication Date:2024-06-03
    connections must be adhered to. In the absence of local codes, the installation must conform with CSA B149.1 "latest edition" Natural gas and propane installation code. The latest code may be obtained from the Canadian Standards Association 178 Rexdale Blvd. Toronto, ON Canada M9W 1R3, 1-800-463-6727
  • Media type icon

    THER-IN-33C_10202023

    Document Title:Outdoor Thermostat - Model BAYSTAT033AC for use with TTA060, 090, 120, 180, and 240, TTA090 - 120A, TTA120, 180C, 240F, WCC018 - 060F, DCX030-036F, *WC*024-60
    Publication Type:Installation
    Publication Date:2023-10-20
    . (See Figure 2). Figure 2 - Thermostat Detail 4. Route the low voltage wires from the air handler and/or heat pump through the bushing of the ODT enclosure.Make the connections to the ODT per the air handler and/or heat pump interconnecting wiring diagram provid-ed in the unit IOM and/or the unit. 5
  • Media type icon

    18-AD35D1-2E-EN_06182020

    Document Title:Installer's Guide - Cased Aluminum "Convertible" Coils 4TXC-DS
    Publication Type:Installation
    Publication Date:2020-06-23
    matching up the edge of the gasket material to the inner edge of the drain pan by the coil fins and working outwards. d. The gasket material can be cut or ripped easily so that it can be tailored to fit. The gasket material must cover the three sides along the entire length of the coil as shown in
  • Media type icon

    RT-SVX22V-EN_04022020

    Document Title:Packaged Rooftop Air Conditioners Precedent™ — Electric/Electric 3 to 10 Tons – 60 Hz
    Publication Type:Installation Operation and Maintenance
    Publication Date:2020-04-02
    provide the required clearance for proper operation. • Assemble and install the roof curb (if applicable). Refer to the latest edition of the curb installers guide that ships with each curb kit. • Fabricate and install ductwork; secure ductwork to curb. • Install pitch pocket for power supply through