Search Results: 18-HE125D1-1C-EN

Showing 261 - 270 of 7,117 results

Display results per page.
  • Media type icon

    MCX6-PRC804-EN_11011998

    Document Title:Stylus Mini-Split System Air Conditioning, 1 - 5 Tons Convertible Models, 60 Hz. Models- MCX512E1, MCX518E1, MCX524E1, MCX536E1, MCX042E1, MCX048E1, MCX060E1
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:1998-11-01
    evacuated refrigerant piping.5Max. linear length 80 ft; Max. lift –– suction 60 ft; Max. length of precharged tubing 50 ft. For greater length refer to Refrigerant Piping Manual, Pub. No. 32-3009. GeneralData 18 MCX6-PRC804-EN Product Specifications1,2 Outdoor Units TTK530K100C TTK536K100C
  • Media type icon

    18-EB30D1-1G-EN_06152020

    Document Title:Installer's Guide Single Packaged Cooling/Electric Heat Model 4TCC4
    Publication Type:Installation
    Publication Date:2020-06-15
    Cooling/Electric Heat14 SEER Convertible, 2 — 5 Ton4TCC4024A1000A4TCC4030A1000A4TCC4036A1000A4TCC4042A1000A4TCC4048A1000A4TCC4060A1000A NNoottee:: “Graphics in this document are for representation only. Actualmodel may differ in appearance.” Installer’s Guide ©2020 18-EB30D1-1G-EN SAFETY
  • Media type icon

    18-GJ11D1-4A-EN_08052020

    Document Title:Installers Guide Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers - BAYUVCLK001 - 40 Watt, 2 Lamp
    Publication Type:Installation
    Publication Date:2020-08-11
    18-GJ11D1-4A-EN Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers Models:BAYUVCLK001 - 40 Watt, 2 Lamp Kit Contents (Items 4-10 are not pictured) Item Qty Description 1 1 Right Side UV Lamp and Bracket Assembly 2 1 Left Side UV Lamp and Bracket Assembly3 1 Ballast and Control Assembly with door
  • Media type icon

    18-GJ11D1-4A-EN_08052020

    Document Title:Installers Guide Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers - BAYUVCLK001 - 40 Watt, 2 Lamp
    Publication Type:Installation
    Publication Date:2020-08-11
    18-GJ11D1-4A-EN Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers Models:BAYUVCLK001 - 40 Watt, 2 Lamp Kit Contents (Items 4-10 are not pictured) Item Qty Description 1 1 Right Side UV Lamp and Bracket Assembly 2 1 Left Side UV Lamp and Bracket Assembly3 1 Ballast and Control Assembly with door
  • Media type icon

    18-AC131D1-1A-EN_04232024

    Document Title:Trane Installation and Operation Manual - Condensing Units - 5TTA3036 - 060
    Publication Type:Installation
    Publication Date:2024-04-23
    18-AC131D1-1A-EN ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT – This document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. Condensing Units5TTA3036 - 060 Installation and
  • Media type icon

    12134863B_11212024

    Document Title:INTELLICORE RA SCHEMATIC 80-120T POWER
    Publication Type:Wiring Diagram or Manual
    Publication Date:2024-11-21
    PTC Plotter Output LEGENDREF DES DESCRIPTION LINE NO1F10 FUSEBLOCK - CONDENSER FAN, CIRCUIT 1 871F11 FUSEBLOCK - CONDENSER FAN, CIRCUIT 2 871QA1 CIRCUIT BREAKER - COMPRESSOR 1A 771QA2 CIRCUIT BREAKER - COMPRESSOR 1B 791QA3 CIRCUIT BREAKER - COMPRESSOR 1C 821QA4 CIRCUIT BREAKER - COMPRESSOR 2A
  • Media type icon

    18-HD100D1-1A-EN_03082023

    Document Title:8 Port Distribution Board
    Publication Type:Installation
    Publication Date:2023-08-03
    18-HD80D1-1 18-HD100D1-1A-EN Installation Guide 8 Port Distribution Board ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES. IMPORTANT - Proper application is critical when installing zoning systems. Not done correctly, the HVAC and zoning system will not provide the
  • Media type icon

    5071-0527D_06062021

    Document Title:CenTraVac® Schematic AdaptiView Panel Upgrade with Subpanel Customer Supplied Starters Auto Transformer
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-06-06
    L'UTILISATION DE TOUT AUTRE CONDUCTEUR AutoCAD SHX Text LES BORNES DE L'UNITÉ NE SONT AutoCAD SHX Text PEUT ENDOMMAGER L'蒕UIPEMENT. AutoCAD SHX Text TYPES DE CONDUCTEURS. AutoCAD SHX Text EN CUIVRE! AutoCAD SHX Text SI NO LO HACE, PUEDE OCASIONAR AutoCAD SHX Text TILICE 贜ICAMENTE CONDUCTORES
  • Media type icon

    18-AC51D5-5-ES_01012010

    Document Title:Instrucciones de Instalación Unidad Condensadora 50 Hz Lang-Spanish
    Publication Type:Installation
    Publication Date:2010-01-01
    www.trane.com Número de Catálogo ................................................................................18-AC51D5-5-ES Fecha ............................................................................................................Diciembre, 2009 En virtud de que Trane mantiene una política de
  • Media type icon

    SS-PRC049A-EN_08112024

    Application Considerations 18 SS-PRC049A-EN Selection ProcedureCooling Capacity 1. Calculate the building’s total and sensible cooling loads at design conditions, using standardizedcalculation methods. 2. Size the equipment using the gross cooling capacity tables. Match the cooling loads at