    18-GE15D1-2_10012008

    Document Title:Installer's Guide Variable Speed - Communicating Air Handlers with Integrated Whole House Air Cleaner 4TEE3D01B through 4TEE3D10B
    Publication Type:Installation
    Publication Date:2008-10-01
    the shield beforebrazing. See Figure 19. IMPORTANT: Do NOT unseal refrigerant tubing untilready to cut and fit refrigerant lines. 1. Remove both sealing caps from indoor coil.2. Field supplied tubing should be cut squared-off, en- suring the tube is still round and free of burrs atthe connecting end
  • Media type icon

    MS-SVN34D-EN_06112020

    Document Title:Installer's Manual Split System (R-410A) Air Handler for Multi Split Inverter System Ceiling Concealed Type Model 4MXD85
    Publication Type:Installation
    Publication Date:2020-06-22
    nsci ous prin t pra ctic es. © 2 020 MS -SV N34 D-E N 11 J un 2 020 S uper sede s M S-S VN 34C -EN (J anua ry 2 016) The AH RI Cer tifie d m ark indi cate s co mpa ny p artic ipat ion in t he A HR I C ertif icat ion prog ram . F or v erifi catio n of indi vidu al c ertif ied prod ucts , go to a hrid
  • Media type icon

    VEN-PRC005A-EN_06012015

    Document Title:Trane Supply - IDG Industrial Distribution Group - Safety and Service Supplies
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2015-06-01
    life of the sling, not just the life of the tag Lift All Endless RoundslingPolyester - Tuflex Tuflex Endless (EN) the most versatile Tuflex roundsling maintains all the basic Tuflex features plus promotes safety and save you money.• Load stability and balance can be achieved by spreading sling legs
  • Media type icon

    18-HE103D1-1A-EN_07012018

    Document Title:Envirowise 98H Whole House Ventilating Dehumidifier EDHUM098
    Publication Type:Installation
    Publication Date:2018-07-01
    right to change design and specifi cations without notice. We are committed to using environmentally conscious print practices. 18-HE103D1-1A-EN (JUL 2018)Supersedes (NEW) ©2018 Ingersoll Rand | all rights reserved
  • Media type icon

    18-GE10D1-5_03012008

    Document Title:Installer's Guide- Convertible Variable Speed – Air Handlers 2 1/2 - 5 Ton with Integrated Whole House Air Cleaner 2/4TEE
    Publication Type:Installation
    Publication Date:2008-03-01
    cut squared-off, en- suring the tube is still round and free of burrs atthe connecting end. Clean the tubing to preventcontaminants from entering the system. 3. Run refrigerant tubing into the stub sockets of in-door unit coil. Refrigerant line openings must becompletely sealed. 4. Braze and evacuate
  • Media type icon

    18-GJ47D1-5_11012015

    Document Title:Installer's Guide - 50 Hz Convertible Air Handlers 3 - 5 Ton GAF2A0A36S3ASC, GAM2A0C48S4ASC, GAM2A0C60S5ASC
    Publication Type:Installation
    Publication Date:2015-11-01
    refrigeration tubing; the rated tubing diameters are located in the electronic performance data system. 3. If the refrigeration lines exceed 60 feet in linear length and / or if alternate size refrigeration tubing is present at the job, please consult SS-APG006-EN or 32-3312-**(latest version) Table
  • Media type icon

    RSP-PRC043-EN_08012007

    Document Title:Service First HVAC/R and Plumbing Equipment Catalog.
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2007-08-01
    -535-0557 • International Customer Care: 905-827-9777 / FAX 905-827-9797www.turbotorch.com Form No. 56-1252 (08/07) © Thermadyne Industries, Inc., 2007 www.thermadyne.com Printed in U.S.A. TM SERVICEFIRST ® Literature Order # RSP-PRC043-EN
  • Media type icon

    5732-0011F_03182021

    Document Title:Ascend Model ACS, Schematic Wiring
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-03-18
    . AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE!L'UTILISATION DE MATÉRIAUX, AUTRES QUE LE CUIVRE,PEUT ENDOMMAGER L'ÉQUIPEMENT, CELUI-CI N'AYANT PAS ÉTÉ CONÇU OUHOMOLOGUÉ POUR ACCEPTER D'AUTRES TYPES DE CONDUCTEURS. NOTICEUSE COPPER CONDUCTORS ONLY! FAILURE TO USE COPPER CONDUCTORSCOULD RESULT IN EQUIPMENT
  • Media type icon

    5732-2800B_10122021

    Document Title:Schematic Wiring ACSA - ACXA Unit / Wiring Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-10-12
    DES CONDUCTEURS EN CUIVRE!L'UTILISATION DE MATÉRIAUX, AUTRES QUE LE CUIVRE,PEUT ENDOMMAGER L'ÉQUIPEMENT, CELUI-CI N'AYANT PAS ÉTÉ CONÇU OUHOMOLOGUÉ POUR ACCEPTER D'AUTRES TYPES DE CONDUCTEURS. NOTICEUSE COPPER CONDUCTORS ONLY! FAILURE TO USE COPPER CONDUCTORSCOULD RESULT IN EQUIPMENT DAMAGEAS THE
  • Media type icon

    18-CD23D1-9_03012011

    Document Title:Installer's Guide - Upflow/Horizontal and Downflow/Horizontal, Gas-Fired, Direct Vent, Variable Speed Inducer, 3-Stage Condensing Communicating Furnaces Models: AUH3, TUH3, ADH3, TDH3
    Publication Type:Installation
    Publication Date:2011-03-01
    LIM ITE D TO 2-1 /2" OR 3" ON SO ME MO DE LS A T D IFF ER EN T ALT ITU DE S. RE FE R T O T HE VE NT LEN GT H T AB LE FO R P RO PE R A PP LIC AT ION . *UH 3-A C-V OU TLIN E D RA WIN G(A LL D IME NS ION S A RE IN IN CH ES ) MO DE L(S EE NO TE 1) DIM "A "D IM " B" DIM "C "D IM " D" DIM "E "D IM " F