Search Results: BAS-SVN226C-EN

Showing 2,351 - 2,360 of 7,117 results

Display results per page.
  • Media type icon

    18-GE06D1-4_03012007

    Document Title:Installer's Guide- II systems Convertible Variable Speed Two Circuit Air Handler 3 - 5 Ton 4TEE3F62B1000A
    Publication Type:Installation
    Publication Date:2007-03-01
    be cut squared-off, en- suring the tube is still round and free of burrs atthe connecting end. Clean the tubing to preventcontaminants from entering the system. 3. Run refrigerant tubing into the stub sockets of in-door unit coil. Refrigerant line openings must becompletely sealed. 4. Braze and
  • Media type icon

    RSP-PRC042-EN_08012007

    Document Title:Trane HVAC/R and Plumbing Equipment Catalog.
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2007-08-01
    -535-0557 • International Customer Care: 905-827-9777 / FAX 905-827-9797www.turbotorch.com Form No. 56-1252 (08/07) © Thermadyne Industries, Inc., 2007 www.thermadyne.com Printed in U.S.A. Literature Order # RSP-PRC042-EN
  • Media type icon

    88-M5MHWUN-1A-EN_10222024

    M5MHW1936A1N0A 23 M5THS2309A11NA M5MHWUN09A1N0A M5THS2312A11NA M5MHWUN12A1N0A M5THS2318A11NA M5MHWUN18A1N0A M5THS2324A11NA M5MHWUN24A1N0A 88-M5MHWUN-1A-EN CONTENTS SAFETY PRECAUTIONS ....................................................................................... 1 NAME OF PARTS
  • Media type icon

    18-GE12D1-8_06012010

    Document Title:Installer's Guide- Convertible Variable Speed – Air Handlers 3.5 - 5 Ton 4TEE3F39A, 48A, 48B, 64A
    Publication Type:Installation
    Publication Date:2010-06-01
    therefrigerant fittings while brazing. Wet the shield beforebrazing. See Figure 16. IMPORTANT:Do NOT unseal refrigerant tubing until ready to cut andfit refrigerant lines. 1. Remove both sealing caps from indoor coil.2. Field supplied tubing should be cut squared-off, en- suring the tube is still round and
  • Media type icon

    18-GE08D1-10_06012012

    Document Title:Installer's Guide Convertible Air Handlers 2 - 5 Ton 4TEC3F
    Publication Type:Installation
    Publication Date:2012-06-01
    field wiring en-ters the cabinet must be completely sealed. Location of power entry is shown on the outline drawing. Use 2.5" clear stickers to seal all unused electrical knockouts. NOTE: If air handler is used with or without a heater, the 7/8" electrical entry hole as well as any other cabi-net
  • Media type icon

    22-1806-04_04012009

    Document Title:Trane Communicating Only Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent 3 Stage Gas Furnace with Variable Speed Inducer TUH3 and TDH3
    Publication Type:Product Data
    Publication Date:2009-04-01
    distance of any single cablefrom a transformer is 250 ft. 18 AWG. NO TES :1 .D IAM ET ER OF VE NT PIP E M AY BE LIM ITE D TO 2-1 /2" OR 3" ON SO ME MO DE LS A T D IFF ER EN T ALT ITU DE S. RE FE R T O T HE VE NT LEN GT H T AB LE FO R P RO PE R A PP LIC AT ION . TU H3- AC -V O utl ine Dra win g(A LL D IME
  • Media type icon

    5722-7670M_03182021

    Document Title:Sintesis™ Model RTAF, 280 to 520 Tons, Schematic Diagram
    Publication Type:Wiring Diagram or Manual
    Publication Date:2021-03-18
    STANDARD EFFICIENCY 390, 520THIGH EFFICIENCY 280-500T JESSICA YUAN 30-APR-2015 18-FEB-2019 AVISO¡UTILICE ÚNICAMENTE CONDUCTORES DE COBRE!LAS TERMINALES DE LA UNIDAD NOESTÁN DISEÑADAS PARA ACEPTAROTROS TIPOS DE CONDUCTORES. NO REALIZAR LO ANTEDICHO PUEDEPROVOCAR DAÑOS EN EL EQUIPO. AVISN'UTILISER QUE
  • Media type icon

    18-GE04D2-15_06012010

    Document Title:Installer's Guide - Convertible Variable Speed - Air Handlers. 2-1/2 - 5 Ton Models: 4TEE3F
    Publication Type:Installation
    Publication Date:2010-06-01
    -dler. IMPORTANT:Do NOT unseal refrigerant tubing until ready to cut andfit refrigerant lines. 1. Remove both sealing caps from indoor coil.2. Field supplied tubing should be cut squared-off, en- suring the tube is still round and free of burrs atthe connecting end. Clean the tubing to
  • Media type icon

    2311-5913C_06202025

    Document Title:Schematic; RTAF Standard Efficiency 390, 520T High Efficiency 280-500T
    Publication Type:Wiring Diagram or Manual
    Publication Date:2025-06-20
    TERMINALES DE LA UNIDAD NOESTÁN DISEÑADAS PARA ACEPTAROTROS TIPOS DE CONDUCTORES. NO REALIZAR LO ANTEDICHO PUEDEPROVOCAR DAÑOS EN EL EQUIPO. AVISN'UTILISER QUE DES CONDUCTEURS EN CUIVRE!LES BORNES DE L'UNITÉ NE SONTPAS CONÇUES POUR RECEVOIR D'AUTRES TYPES DE CONDUCTEURS.UN MANQUEMENT À LA PROCÉDURE CI
  • Media type icon

    VEN-PRC004A-EN_01292015

    Document Title:Trane Supply - Nu-Calgon catalog
    Publication Type:Product Catalog or Quick Reference Guide
    Publication Date:2015-01-29
    N CL EAN EVAP -GRE EN™ CAL- GREE N™ CAL- BRIT E®CA LCLE AN® NU- BLAS T®SP ECIA L HD CALC LEAN ®N U-BR ITE® FOAM -BRI TE® ALKA -BRI TE® P LUS CALC LEAN ® TRIC LEAN 2X NU- BRIT E®NU -SHI ELD Visit us at www.nucalgon.com 7 NuCalgon # Mnemonic5 (up to 5 tons) 4295-34 CHM004645 Slim (up to 5 tons) 4295